Download Print this page

GE Dialog QS1500 00 Touchtalk Installation Instructions

Interactive keypad

Advertisement

Quick Links

'
*( 6HFXULW\
*(6HFXULW\FRP
Product
Summary
Part No. 60-924-01-3
Installation
The wall-mounted wireless Dialog QS1500 Touchtalk Interactive Keypad combines a conven-
tional Learn Mode
keypad with an RF receiver, speech chip, and voice amplification circuit for
your Simon 3
security system.
®
The QS1500 Touchtalk Interactive Keypad is an alkaline battery-powered, wireless keypad
designed to provide users a convenient option for the following system operations:
Arm the system (doors, windows, and motion sensors).
Arm the system with No Entry Delay.
Disarm the system.
Activate a panic alarm to call the central monitoring station in a non-medical emergency.
Check system status.
Turn system controlled lights on or off (all or individual).
Enables the user to hear the voice feedback that is heard at the Simon 3 Control Panel.
The keypad has two operating modes: key and chime.
In key mode, voice feedback is heard only at the keypad when a system command is entered.
Examples of this would be: system status, arming and disarming. In this mode the keypad does
not repeat siren sounds and will not make any alarm sounds or status beeps. This feature extends
battery life to the keypad and gives feedback only to the user who needs it. When the keypad is
in key mode it is compatible with Simon 3 panels version 3.3 and newer.
In chime mode, all voice feedback that is heard in key mode, plus, trouble beeps, entry/exit
beeps and alarm sounds (Fire, Aux, Police) are heard at the keypad. The keypad will also
respond to panel broadcast messages at multiple keypads. While in chime mode the keypad can
be supervised and will send supervision messages to the panel. In chime mode the keypad is
compatible with Simon 3 panels version 4.0 and newer
Voice feedback depends on how Simon 3 panel options 41 and 87 are set. See the Simon 3 Instal-
lation Instructions (466-1873) for more information.
!
The keypad has limited audio power. Therefore, the keypad should not be relied on for
alarm announcements and is no substitute for an alarm siren.
Warning
Voice feedback is heard at all keypads. If the keypad is talking, the panel is silent. When the
panel is talking, the keypad is silent.
The keypad has no tamper detection. A low battery condition is automatically detected by the
keypad and communicated to the control panel.
Installation of the QS1500 Touchtalk Interactive Keypad includes guidelines for installing, pro-
gramming, sensor testing, improving sensor communication and mounting the keypad.
Installation Guidelines
Use the following guidelines when adding this keypad to your Simon 3 system:
Program the keypad as key or chime mode.
Keypads are learned into the control panel as sensors.
'LDORJ 46 7RXFKWDON
,QWHUDFWLYH .H\SDG
,QVWDOODWLRQ ,QVWUXFWLRQV
'RFXPHQW 1XPEHU  5HY $
-XQH 
1

Advertisement

loading

Summary of Contents for GE Dialog QS1500 00 Touchtalk

  • Page 1 'LDORJ 46 7RXFKWDON ,QWHUDFWLYH .H\SDG *( 6HFXULW\ ,QVWDOODWLRQ ,QVWUXFWLRQV *(6HFXULW\FRP 'RFXPHQW 1XPEHU  5HY $ -XQH  Product The wall-mounted wireless Dialog QS1500 Touchtalk Interactive Keypad combines a conven- tional Learn Mode keypad with an RF receiver, speech chip, and voice amplification circuit for ™...
  • Page 2 • Key mode keypads should be programmed using sensor groups 01, 03, 06, or 07 for non supervised use. • Chime mode keypads can be programmed using sensor groups 01, 03, 06 or 07 for non supervised use or sensor groups 00, 02, 04 or 05 for supervised use. •...
  • Page 3 (i.e. “System Dis- armed”). If panel sirens do not beep when a keypad is tripped, use a GE Security RF Sniffer (60-401) test tool to verify that the keypad is transmitting. Constant beeps from the RF Sniffer indicate a run- away (faulty) keypad.
  • Page 4 4. Reattach the keypad to the mounting plate. Testing the Keypad After Mounting Repeat the steps listed in the “Performing a Sensor Test” section in this manual. Note While the sensor test is a valuable installation and ser- Keypad Operation vice tool, it only tests sensor operation for the current •...

This manual is also suitable for:

60-924-01-3