Before use, make sure the system has been installed correctly by an
authorised dealer according to the given instructions.
Panasonic Air-to-Water Heatpump is a split system, consisting of two units: indoor and outdoor units. This system is designed
to operate with Panasonic Water Tank Unit. Unless used together with the Panasonic Water Tank Unit, Panasonic does not
guarantee any normal operation nor the reliability of the system.
These operating instructions describe how to operate the system using the indoor and outdoor units.
As for the operation of other products such as water tank, radiator, external thermo controller, and underfl oor units, refer to the
operating instructions of each product.
Some functions described in this manual may not be applicable to your system.
Consult your nearest authorised dealer for further information.
System overview
Remote Controller
Note:
Not recommended to open the Front Plate.
(For authorised dealer/specialist use only)
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
They are subject to change without notice for future improvement.
Operating conditions
Water outlet temperature (°C)
(Min. / Max.)
Outdoor ambient temperature (°C)
(Min. / Max.)
When the outdoor temperature is out of the range in the table, the heating capacity will drop signifi cantly and the outdoor unit may stop
operating for its protection.
The unit will restart automatically after the outdoor temperature returns to the specifi ed range.
*
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
1
*
Only displayed when COOL mode is unlocked (This means when COOL mode is available)
2
*
Between outdoor ambient -10 °C and -15 °C, the water outlet temperature gradually decreases from 60 °C to 55 °C.
3
Solar Panel
Front Plate
Indoor Unit
Outdoor
Unit
Power Supply
HEATING (CIRCUIT)
20 / 55 (Below Ambient -15 °C) *
20 / 60 (Above Ambient -10 °C) *
-20 / 35 (WH-UDZ03KE5)
-25 / 35 (WH-UDZ05/07/09KE5)
-28 / 35 (WH-UXZ series)
Water Tank Unit
*
*
COOLING (CIRCUIT)
1,
2
3
3
Radiator
Shower
Fan Coil
Unit
Floor
Heating
5 / 20
10 / 43
3