Honeywell Youjie YJ-HF600 User Manual
Honeywell Youjie YJ-HF600 User Manual

Honeywell Youjie YJ-HF600 User Manual

Area-imaging scanner
Table of Contents

Advertisement

Quick Links

Youjie™ YJ-HF600
Area-Imaging Scanner
User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Youjie YJ-HF600

  • Page 1 Youjie™ YJ-HF600 Area-Imaging Scanner User’s Guide...
  • Page 2 Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made.
  • Page 3: Table Of Contents

    ® Verifone Ruby Terminal Default Settings................2-3 ® Gilbarco Terminal Default Settings ..................2-3 Honeywell Bioptic Aux Port Configuration ................2-3 ® Datalogic™ Magellan Aux Port Configuration..............2-4 NCR Bioptic Aux Port Configuration ..................2-4 Wincor Nixdorf Terminal Default Settings ................2-4 Wincor Nixdorf Beetle™ Terminal Default Settings .............2-5 Wincor Nixdorf RS232 Mode A ....................2-5...
  • Page 4 RS232 Modifiers ........................ 2-16 RS232 Baud Rate......................2-16 RS232 Word Length: Data Bits, Stop Bits, and Parity ..........2-17 RS232 Receiver Time-Out................... 2-18 RS232 Handshaking....................2-19 RS232 Timeout......................2-19 XON/XOFF ........................2-19 ACK/NAK ........................2-20 Scanner to Bioptic Communication ................... 2-20 Scanner-Bioptic Packet Mode ..................
  • Page 5 Chapter 4 - Data Editing Prefix/Suffix Overview ......................4-1 To Add a Prefix or Suffix:....................4-1 To Clear One or All Prefixes or Suffixes ................ 4-2 To Add a Carriage Return Suffix to All Symbologies ............. 4-2 Prefix Selections........................4-2 Suffix Selections ........................
  • Page 6 Code 128 ........................... 6-14 ISBT 128 Concatenation....................6-14 Code 128 Code Page ....................6-15 GS1-128 ..........................6-16 UPC-A ..........................6-17 UPC-A/EAN-13 with Extended Coupon Code ..............6-18 Coupon GS1 DataBar Output.................... 6-19 UPC-E0 ..........................6-19 UPC-E1 ..........................6-21 EAN/JAN-13 ........................6-22 Convert UPC-A to EAN-13 ..................
  • Page 7 Chapter 8 - Utilities To Add a Test Code I.D. Prefix to All Symbologies ............. 8-1 Show Decoder Revision ...................... 8-1 Show Scan Driver Revision ....................8-1 Show Software Revision...................... 8-1 Show Data Format....................... 8-1 Test Menu..........................8-2 Resetting the Factory Defaults .................... 8-2 Chapter 9 - Serial Programming Command Conventions.........................
  • Page 8 Programming Chart...
  • Page 9: Customer Support

    For our latest contact information, please check our website at the link above. Product Service and Repair Honeywell International Inc. provides service for all of its products through service centers throughout the world. To obtain warranty or non-warranty service, please visit www.honeywellaidc.com...
  • Page 10 viii...
  • Page 11: Chapter 1 - Getting Started

    Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide.
  • Page 12: Connecting With Rs232 Serial Port

    Connecting with RS232 Serial Port 1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the scanner. Note: For the scanner to work properly, you must have the correct cable for your type of terminal/computer. 3. Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port.
  • Page 13: Reading Techniques

    Menu Bar Code Security Settings Honeywell scanners are programmed by scanning menu bar codes or by sending serial commands to the scanner. If you want to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings. Please contact the nearest techni-...
  • Page 14 1 - 4...
  • Page 15: Chapter 2 - Programming The Interface

    Programming the Interface Introduction This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Keyboard Wedge If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard, scan the bar code below.
  • Page 16: Usb Ibm Surepos

    USB IBM SurePos Scan one of the following “Plug and Play” codes to program the scanner for an IBM SurePos (USB handheld scanner) or IBM SurePos (USB tabletop scanner) interface. Note: After scanning one of these codes, you must power cycle the cash register. USB IBM SurePos (USB Handheld Scanner) Interface...
  • Page 17: Usb Serial Port Emulation

    Honeywell Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 38400 bps and the data format to 8 data bits, no parity, 1 stop bit.
  • Page 18: Datalogic™ Magellan ® Aux Port Configuration

    ® Datalogic™ Magellan Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Datalogic Magellan auxiliary port configuration. This bar code sets the baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit. Datalogic Magellan Settings NCR Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for an NCR bioptic scanner auxiliary port configuration.
  • Page 19: Wincor Nixdorf Beetle™ Terminal Default Settings

    Wincor Nixdorf Beetle™ Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf Beetle terminal. The following prefixes are programmed for each symbology: Symbology Prefix Symbology Prefix Aztec Code Interleaved 2 of 5 Codabar MaxiCode Code 93...
  • Page 20 Keyboard Countries (Continued) Albania Azeri (Cyrillic) Azeri (Latin) Belarus Belgium Bosnia Brazil Brazil (MS) Bulgaria (Cyrillic) Bulgaria (Latin) Canada (French legacy) 2 - 6...
  • Page 21 Keyboard Countries (Continued) Canada (French) Canada (Multilingual) Croatia Czech Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) Estonia Faroese 2 - 7...
  • Page 22 Keyboard Countries (Continued) Finland France Gaelic Germany Greek Greek (220 Latin) Greek (220) Greek (319 Latin) Greek (319) Greek (Latin) Greek (MS) 2 - 8...
  • Page 23 Keyboard Countries (Continued) Greek (Polytonic) Hebrew Hungarian (101 key) Hungary Iceland Irish Italian (142) Italy Japan ASCII Kazakh Kyrgyz (Cyrillic) 2 - 9...
  • Page 24 Keyboard Countries (Continued) Latin America Latvia Latvia (QWERTY) Lithuania Lithuania (IBM) Macedonia Malta Mongolian (Cyrillic) Norway Poland Polish (214) 2 - 10...
  • Page 25 Keyboard Countries (Continued) Polish (Programmers) Portugal Romania Russia Russian (MS) Russian (Typewriter) Serbia (Cyrillic) Serbia (Latin) Slovakia Slovakia (QWERTY) 2 - 11...
  • Page 26 Keyboard Countries (Continued) Slovakia (QWERTZ) Slovenia Spain Spanish variation Sweden Switzerland (French) Switzerland (German) Tatar Turkey F Turkey Q Ukrainian 2 - 12...
  • Page 27: Keyboard Style

    Keyboard Countries (Continued) United Kingdom United States (Dvorak) United States (Dvorak left) United Stated (Dvorak right) United States (International) Uzbek (Cyrillic) Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. If you have used Keyboard Conversion settings, they will override any of the following Keyboard Style settings.
  • Page 28: Keyboard Conversion

    Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off . This selection can only be used with systems that have an LED that notes the Caps Lock status (AT keyboards). Automatic Caps Lock Autocaps via NumLock bar code should be scanned in countries (e.g., Germany, France) where the Caps Lock key cannot be used to toggle Caps Lock.
  • Page 29: Control Character Output

    Control Character Output This selection sends a text string instead of a control character. For example, when the control character for a carriage return is expected, the output would display [CR] instead of the ASCII code of 0D. Refer to ASCII Conversion Chart (Code Page 1252) on page A-3.
  • Page 30: Rs232 Modifiers

    Turbo Mode: The scanner sends characters to a terminal faster. If the terminal drops characters, do not use Turbo Mode. Default = Off. Turbo Mode On * Turbo Mode Off Numeric Keypad Mode: Sends numeric characters as if entered from a numeric keypad. Default = Off. Numeric Keypad Mode On * Numeric Keypad Mode Off Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping...
  • Page 31: Rs232 Word Length: Data Bits, Stop Bits, And Parity

    1200 2400 4800 9600 19200 38400 57,600 * 115,200 RS232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits.
  • Page 32: Rs232 Receiver Time-Out

    7 Data, 1 Stop, Parity None 7 Data, 1 Stop, Parity Odd 7 Data, 2 Stop, Parity Even 7 Data, 2 Stop Parity None 7 Data, 2 Stop, Parity Odd 8 Data, 1 Stop, Parity Even * 8 Data, 1 Stop, Parity None 8 Data, 1 Stop, Parity Odd 8 Data, 1 Stop, Parity Mark RS232 Receiver Time-Out...
  • Page 33: Rs232 Handshaking

    RS232 Handshaking RS232 Handshaking allows control of data transmission from the scanner using software commands from the host device. When RTS/CTS is turned Off, no data flow control is used. Flow Control, No Timeout: The scanner asserts RTS when it has data to send, and will wait indefinitely for CTS to be asserted by the host.
  • Page 34: Ack/Nak

    Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scanners and bioptic scanners. Note: The scanner’s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with a bioptic scanner.
  • Page 35: Scanner-Bioptic Ack/Nak Timeout

    Bioptic ACK/NAK On Scanner-Bioptic ACK/NAK Timeout This allows you to set the length (in milliseconds) for a timeout for a bioptic scanner’s ACK/NAK response. Scan the bar code below, then set the timeout (from 1-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.
  • Page 36 2 - 22...
  • Page 37: Chapter 3 - Input/Output Settings

    Input/Output Settings Power Up Beeper The scanner can be programmed to beep when it’s powered up. Scan the Off bar code(s) if you don’t want a power up beep. Default = Power Up Beeper On - Scanner. Power Up Beeper Off * Power Up Beeper On Beep on BEL Character You may wish to force the scanner to beep upon a command sent from the host.
  • Page 38: Good Read And Error Indicators

    Good Read and Error Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = Beeper - Good Read On. Beeper - Good Read Off * Beeper - Good Read On Beeper Volume –...
  • Page 39: Beeper Duration - Good Read

    High (4200 Hz) Beeper Pitch – Error The beeper pitch codes modify the pitch (frequency) of the sound the scanner emits when there is a bad read or error. Default = Razz. * Razz (250 Hz) Medium (3250 Hz) High (4200 Hz) Beeper Duration –...
  • Page 40: Number Of Beeps - Good Read

    Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read. For example, if you program this option to have five beeps, there will be five beeps and five LED flashes in response to a good read.
  • Page 41: Serial Trigger Mode

    Serial Trigger Mode You can activate the scanner either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 9-3). When in serial mode, the scanner scans until a bar code has been read or until the deactivate command is sent. The scanner can also be set to turn itself off after a specified time has elapsed (see Read Time-Out, which follows).
  • Page 42: 2D Reread Delay

    Reread Delay This sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads. Use shorter delays in applications where repetitive bar code scanning is required.
  • Page 43: Character Activation Mode

    Long (3000ms) Extra Long (4000ms) Character Activation Mode You may use a character sent from the host to trigger the scanner to begin scanning. When the activation character is received, the scanner continues scanning until either the Character Activation Timeout (page 3-8) or a bar code is transmitted.
  • Page 44: Character Activation Timeout

    Character Activation Timeout You can set a timeout for the length of time the illumination remains on and attempting to decode bar codes when using Character Activation Mode. Set the length (in milliseconds) for a timeout by scanning the following bar code, then setting the timeout (from 1-300,000 milliseconds) by scanning digits from the Programming Chart inside the back cover of this...
  • Page 45: Streaming Presentation™ Mode

    Streaming Presentation™ Mode When in Streaming Presentation - Normal mode, the scanner leaves the scan illumination on all the time and continuously searches for bar codes. When in Streaming Presentation - Mobile Phone mode, your scanner is optimized to read bar codes from mobile phone or other LED displays.
  • Page 46 In the example below, the white box is the centering window. The centering window has been set to 20% left, 30% right, 8% top, and 25% bottom. Since Bar Code 1 passes through the centering window, it will be read. Bar Code 2 does not pass through the centering window, so it will not be read.
  • Page 47: Video Reverse

    Right of Presentation Centering Window Video Reverse Video Reverse is used to allow the scanner to read bar codes that are inverted. The Video Reverse Off bar code below is an example of this type of bar code. Scan Video Reverse Only to read only inverted bar codes. Scan Video Reverse and Stan- dard Bar Codes to read both types of codes.
  • Page 48: Working Orientation

    Working Orientation Some bar codes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the scanner. Default = Upright. Upright: Vertical, Top to Bottom: (Rotate CW 90°)
  • Page 49: Chapter 4 - Data Editing

    Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string.
  • Page 50: To Clear One Or All Prefixes Or Suffixes

    Step 1. Scan Add Suffix. Step 2. Determine the 2 digit hex value from the Symbology Chart (included in the Symbology Charts, beginning on page A-1) for U.P.C.. Step 3. Scan 6, 3 from the Programming Chart inside the back cover of this manual. Step 4.
  • Page 51: Function Code Transmit

    Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page...
  • Page 52: Interfunction Delay

    Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value for a printable character to trigger the delay (See "ASCII Conversion Chart (Code Page 1252)" on page A-3). Delay Length Character to Trigger Delay To remove this delay, scan the Delay Length bar code, and set the number of delays to 0. Scan the Save bar code using Programming Chart inside the back cover of this manual.
  • Page 53: Chapter 5 - Data Formatting

    Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output.
  • Page 54: Other Programming Selections

    Step 5. Length Specify what length (up to 9999 characters) of data will be acceptable for this symbology. Scan the four digit data length from the Programming Chart inside the back cover of this manual. For example, 50 characters is entered as 0050. Note: 9999 indicates all lengths.
  • Page 55: Terminal Id Table

    Terminal ID Table Terminal Model(s) Terminal ID PC keyboard (HID) Mac Keyboard PC Keyboard (Japanese) Serial (COM driver required) HID POS USB SurePOS Handheld USB SurePOS Tabletop Serial RS232 TTL RS232 True RS485 (IBM-HHBCR 1+2, 46xx) Keyboard PS2 compatibles AT compatibles Data Format Editor Commands When working with the Data Format Editor, a virtual cursor is moved along your input data string.
  • Page 56 F1 is the “Send all characters” command 0D is the hex value for a CR The data is output as: 1234567890 ABCDEFGHIJ <CR> Send all characters up to a particular character F3 Include in the output message all characters from the input message, starting with the character at the current cursor position and continuing to, but not including, the search character “ss,”...
  • Page 57 <CR> Insert symbology name B3 Insert the name of the bar code’s symbology in the output message, without moving the cursor. Only symbologies with a Honeywell ID are included (see Symbology Charts on page A-1). Refer to the ASCII Conversion Chart (Code Page 1252), beginning on page A-3 for decimal, hex and character codes.
  • Page 58: Move Commands

    Insert bar code length B4 Insert the bar code’s length in the output message, without moving the cursor. The length is expressed as a numeric string and does not include leading zeroes. B3 and B4 Example: Insert the symbology name and length Send the symbology name and length before the bar code data from the bar code above.
  • Page 59: Search Commands

    F5 Example: Move the cursor forward and send the data Move the cursor forward 3 characters, then send the rest of the bar code data from the bar code above. End with a carriage return. Command string: F503F10D F5 is the “Move the cursor forward a number of characters” command 03 is the number of characters to move the cursor F1 is the “Send all characters”...
  • Page 60 F8 Example: Send bar code data that starts after a particular character Search for the letter “D” in bar codes and send all the data that follows, including the “D.” Using the bar code above: Command string: F844F10D F8 is the “Search forward for a character” command 44 is the hex value for “D”...
  • Page 61: Miscellaneous Commands

    Search forward for a non-matching character E6 Search the input message forward for the first non-“xx” character from the current cursor position, leaving the cursor pointing to the non-“xx” character. Syntax = E6xx where xx stands for the search character’s hex value for its ASCII code.
  • Page 62 Stop suppressing characters FC Disables suppress filter and clear all suppressed characters. Syntax = FC. Replace characters E4 Replaces up to 15 characters in the output message, without moving the cursor. Replacement continues until the E5 command is encountered. Syntax = E4nnxx ...zz where nn is the total count of the number of characters in the list (characters to be replaced plus replacement characters);...
  • Page 63 If this bar code is read, the next data format, if there is one, will be used on the data. If there is no other format, the format fails and the raw data is output as AB1234. If this bar code is read: the data is output as: 1234AB <CR>...
  • Page 64: Data Formatter

    Data Formatter When Data Formatter is turned Off, the bar code data is output to the host as read, including prefixes and suffixes. Data Formatter Off You may wish to require the data to conform to a data format you have created and saved. The following settings can be applied to your data format: Data Formatter On, Not Required, Keep Prefix/Suffix Scanned data is modified according to your data format, and prefixes and suffixes are transmitted.
  • Page 65: Data Format Non-Match Error Tone

    Data Format Non-Match Error Tone When a bar code is encountered that doesn’t match your required data format, the scanner normally generates an error tone. However, you may want to continue scanning bar codes without hearing the error tone. If you scan the Data Format Non-Match Error Tone Off bar code, data that doesn’t conform to your data format is not transmitted, and no error tone will sound.
  • Page 66 5 - 14...
  • Page 67: Message Length Description

    Symbologies This programming section contains the following menu selections. • MaxiCode • Interleaved 2 of 5 • China Post (Hong Kong 2 of 5) • Korea Post • Chinese Sensible (Han Xin) Code • Label Code • Codabar • Matrix 2 of 5 •...
  • Page 68: Codabar

    Codabar <Default All Codabar Settings> Codabar On/Off * On Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/ Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.”...
  • Page 69: Codabar Concatenation

    Validate Modulo 16 and Transmit Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D”...
  • Page 70: Code 39

    Code 39 < Default All Code 39 Settings > Code 39 On/Off * On Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/ Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Code 39 Check Character...
  • Page 71: Code 32 Pharmaceutical (Paraf)

    Code 39 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 0-48. Minimum Default = 0, Maximum Default = 48. Minimum Message Length Maximum Message Length Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to...
  • Page 72: Full Ascii

    Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off.
  • Page 73: Interleaved 2 Of 5

    Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 On/Off * On Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
  • Page 74: Nec 2 Of 5

    NEC 2 of 5 < Default All NEC 2 of 5 Settings > NEC 2 of 5 On/Off * On Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
  • Page 75: Code 93

    Code 93 < Default All Code 93 Settings > Code 93 On/Off * On Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 93 Append...
  • Page 76: Code 93 Code Page

    Code 93 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting.
  • Page 77: Straight 2 Of 5 Iata (Two-Bar Start/Stop)

    Straight 2 of 5 IATA (two-bar start/stop) <Default All Straight 2 of 5 IATA Settings> Straight 2 of 5 IATA On/Off * Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 78: Matrix 2 Of 5

    Matrix 2 of 5 <Default All Matrix 2 of 5 Settings> Matrix 2 of 5 On/Off * Off Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 79: Code 11

    Code 11 <Default All Code 11 Settings> Code 11 On/Off * Off Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length 6 - 13...
  • Page 80: Isbt 128 Concatenation

    Code 128 <Default All Code 128 Settings> Code 128 On/Off * On ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood informa- tion in a uniform manner. The use of ISBT formats requires a paid license. The ISBT 128 Application Specification describes 1) the critical data elements for labeling blood products, 2) the current recommendation to use Code 128 due to its high degree of security and its space-efficient design, 3) a variation of Code 128 that supports concatenation of neigh- boring symbols, and 4) the standard layout for bar codes on a blood product label.
  • Page 81: Code 128 Code Page

    Code 128 Append This function allows the scanner to append the data from several Code 128 bar codes together before transmitting them to the host computer. When the scanner encounters a Code 128 bar code with the append trigger character(s), it buffers Code 128 bar codes until it reads a Code 128 bar code that does not have the append trigger.
  • Page 82: Gs1-128

    GS1-128 <Default All GS1-128 Settings> GS1-128 On/Off * On GS1-128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80. Minimum Message Length Maximum Message Length 6 - 16...
  • Page 83: Upc-A

    UPC-A <Default All UPC-A Settings> UPC-A On/Off * On Note: When UPC-A Off is scanned, UPC-A bar codes are transmitted as EAN-13. UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
  • Page 84: Upc-A/Ean-13 With Extended Coupon Code

    UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC-A Addenda Required When Required is scanned, the scanner will only read UPC-A bar codes that have addenda.
  • Page 85: Coupon Gs1 Databar Output

    If you scan the Allow Concatenation code, when the scanner sees the coupon code and the extended coupon code in a single scan, it transmits both as separate symbologies. Otherwise, it transmits the first coupon code it reads. If you scan the Require Concatenation code, the scanner must see and read the coupon code and extended coupon code in a single read to transmit the data.
  • Page 86 UPC-E0 Off UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. * Off UPC-E0 Addenda Required When Required is scanned, the scanner will only read UPC-E bar codes that have addenda. Default = Not Required. Required * Not Required UPC-E0 Addenda Separator...
  • Page 87: Upc-E1

    UPC-E0 Leading Zero When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space. Default = On. * On UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On...
  • Page 88: Ean/Jan-13

    * UPC-E1 Off EAN/JAN-13 <Default All EAN/JAN Settings> EAN/JAN-13 On/Off * On Convert UPC-A to EAN-13 When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are converted to 13 digit EAN-13 codes by adding a zero to the front. When Do not Convert UPC-A is selected, UPC-A codes are read as UPC-A. UPC-A Converted to EAN-13 * Do not Convert UPC-A EAN/JAN-13 Check Digit...
  • Page 89 EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-13 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 bar codes that have addenda.
  • Page 90: Isbn Translate

    ISBN Translate When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off. * Off EAN/JAN-8 <Default All EAN/JAN-8 Settings> EAN/JAN-8 On/Off * On EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
  • Page 91 EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that have addenda.
  • Page 92: Msi

    <Default All MSI Settings> MSI On/Off * Off MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data.
  • Page 93 Validate Type 11 then Type 10 Character and Transmit Disable MSI Check Characters MSI Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length 6 - 27...
  • Page 94: Gs1 Databar Omnidirectional

    GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional On/Off * On GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited On/Off * On 6 - 28...
  • Page 95: Gs1 Databar Expanded

    GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > GS1 DataBar Expanded On/Off * On GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 96: Codablock F

    Codablock A Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600. Minimum Message Length Maximum Message Length Codablock F <Default All Codablock F Settings>...
  • Page 97: Label Code

    Label Code The standard Label Code is used in libraries. Default = Off. *Off PDF417 < Default All PDF417 Settings > PDF417 On/Off * On PDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 98: Macropdf417

    MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes. When this selection is enabled, these multiple bar codes are assembled into a single data string. Default = On. * On MicroPDF417 <...
  • Page 99: Gs1 Composite Codes

    GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology. GS1 Composite symbologies allow for the co-existence of symbologies already in use. Default = Off. * Off UPC/EAN Version Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that have a U.P.C.
  • Page 100: Tcif Linked Code 39 (Tlc39)

    If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and UPC-E expansion is controlled by the UPC-E0 Expand (page 6-20) setting. If the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see Symbology Charts page A-1).
  • Page 101: Qr Code

    QR Code < Default All QR Code Settings > QR Code On/Off This selection applies to both QR Code and Micro QR Code. * On QR Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 102: Data Matrix

    Data Matrix < Default All Data Matrix Settings > Data Matrix On/Off * On Data Matrix Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116. Minimum Message Length Maximum Message Length Data Matrix Append...
  • Page 103: Maxicode

    codes were created (see ISO 2022/ISO 646 Character Replacements on page A-7), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly.
  • Page 104: Aztec Code

    Aztec Code < Default All Aztec Code Settings > Aztec Code On/Off * On Aztec Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832. Minimum Message Length Maximum Message Length Aztec Code Page...
  • Page 105: Chinese Sensible (Han Xin) Code

    Chinese Sensible (Han Xin) Code < Default All Han Xin Settings > Han Xin Code On/Off * Off Han Xin Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 106: Combination 2D Postal Codes

    Canadian Post On Intelligent Mail Bar Code On Japanese Post On KIX Post On Planet Code On Also see Planet Code Check Digit, page 6-43. Postal-4i On Postnet On Also see Postnet Check Digit, page 6-43. Postnet with B and B’ Fields On InfoMail On Combination 2D Postal Codes: InfoMail and British...
  • Page 107 Intelligent Mail Bar Code and Postnet with B and B’ Fields On Postnet and Postal-4i On Postnet and Intelligent Mail Bar Code On Postal-4i and Intelligent Mail Bar Code On Postal-4i and Postnet with B and B’ Fields On Planet Code and Postnet On Planet Code and Postnet with B and B’...
  • Page 108 Planet Code, Postnet, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Intelligent Mail Bar Code On Postnet, Postal-4i, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Postnet with B and B’ Fields On Planet Code, Intelligent Mail Bar Code, and Postnet with B and B’...
  • Page 109 Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Planet Code data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Postnet data. Default = Don’t Transmit.
  • Page 110: Postal Codes - Linear

    Combination C and N Tables Postal Codes - Linear The following lists linear postal codes. Any combination of linear postal code selections can be active at a time. China Post (Hong Kong 2 of 5) <Default All China Post (Hong Kong 2 of 5) Settings> China Post (Hong Kong 2 of 5) On/Off * Off China Post (Hong Kong 2 of 5) Message Length...
  • Page 111: Korea Post

    Korea Post <Default All Korea Post Settings> Korea Post * Off Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for addi- tional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Korea Post Check Digit...
  • Page 112 6 - 46...
  • Page 113: Keyboard Function Relationships

    Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-15 enable Control + ASCII mode. Function Code HEX/ASCII Value Full ASCII “CTRL”...
  • Page 114 Country Codes Norway Spain 7 - 2...
  • Page 115: Supported Interface Keys

    Supported Interface Keys IBM PC/AT and Compatibles, Apple Mac/iMac ASCII USB PC Supported Keys Keyboard Reserved Reserved Enter (KP) Enter/Numpad Enter Cap Lock CAPS ALT make ALT make ALT break ALT break CTRL make CNTRL make CTRL break CNTRL break CR/Enter RETURN Reserved...
  • Page 116 7 - 4...
  • Page 117: Chapter 8 - Utilities

    Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Charts, beginning on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D.
  • Page 118: Test Menu

    Test Menu When you scan the Test Menu On code, then scan a programming code in this manual, the scanner displays the content of a programming code. The programming function will still occur, but in addition, the content of that programming code is output to the terminal.
  • Page 119: Chapter 9 - Serial Programming Command

    Serial Programming Command The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the scanner. For complete descriptions and examples of each serial programming com- mand, refer to the corresponding programming bar code in this manual.
  • Page 120: Responses

    Data Field Usage When a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields. Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence.
  • Page 121: Trigger Commands

    the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value. Trigger Commands You can activate and deactivate the scanner with serial trigger commands. First, the scanner must be put in Manual Trigger Mode by scanning a Manual Trigger Mode bar code (page 3-5), or by sending a serial menu command for triggering...
  • Page 122: Menu Commands

    USB HID PAP131 USB Serial Port Emulation TERMID130 Plug and Play Codes Verifone Ruby Terminal PAPRBY Gilbarco Terminal PAPGLB Honeywell Bioptic Aux Port PAPBIO Datalogic Magellan Aux Port PAPMAG NCR Bioptic Aux Port PAPNCR Wincor Nixdorf Terminal PAPWNX Wincor Nixdorf Beetle...
  • Page 123 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Czech KBDCTY15 Czech (Programmers) KBDCTY40 Czech (QWERTY) KBDCTY39 Czech (QWERTZ) KBDCTY38 Denmark KBDCTY8 Dutch (Netherlands) KBDCTY11 Estonia KBDCTY41 Faroese KBDCTY83 Finland KBDCTY2 France KBDCTY3 Gaelic KBDCTY84 Germany KBDCTY4 Greek KBDCTY17...
  • Page 124 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Romania KBDCTY25 Russia KBDCTY26 Russian (MS) KBDCTY67 Russian (Typewriter) KBDCTY68 KBDCTY21 Serbia (Cyrillic) KBDCTY37 Serbia (Latin) KBDCTY36 Slovakia KBDCTY22 Slovakia (QWERTY) KBDCTY49 Slovakia (QWERTZ) KBDCTY48 Slovenia KBDCTY31 Spain KBDCTY10 Spanish variation...
  • Page 125 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Keyboard Modifiers *Control + X Off KBDCAS0 2-15 DOS Mode Control + X KBDCAS1 2-15 Windows Mode Control + X KBDCAS2 2-15 Windows Mode Prefix/Suffix Off KBDCAS3 2-15 *Turbo Mode Off KBDTMD0...
  • Page 126 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Scanner-Bioptic ACK/NAK Mode *Bioptic ACK/NAK Off 232NAK0 2-20 Bioptic ACK/NAK On 232NAK1 2-21 Scanner-Bioptic ACK/NAK Timeout ACK/NAK Timeout 232DLK##### 2-21 *5100 Input/Output Selections Power Up Beeper Power Up Beeper Off - Scanner BEPPWR0 *Power Up Beeper On - Scanner BEPPWR1...
  • Page 127 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Reread Delay Short (500 ms) DLYRRD500 *Medium (750 ms) DLYRRD750 Long (1000 ms) DLYRRD1000 Extra Long (2000 ms) DLYRRD2000 User-Specified Range 0 - 30,000 ms DLYRRD##### 2D Reread Delay *2D Reread Delay Off DLY2RR0 Short (1000ms)
  • Page 128 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Working Orientation *Upright ROTATN0 3-12 Vertical, Bottom to Top (Rotate ROTATN1 3-12 CCW 90°) Upside Down ROTATN2 3-12 Vertical, Top to Bottom (Rotate ROTATN3 3-12 CW 90°) Prefix/Suffix Selections Add CR Suffix to All Symbologies VSUFCR...
  • Page 129 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Primary/Alternate Data Formats Primary Data Format ALTFNM0 5-13 Data Format 1 ALTFNM1 5-13 Data Format 2 ALTFNM2 5-13 Data Format 3 ALTFNM3 5-13 Symbologies Codabar Default All Codabar CBRDFT Settings CBRENA0...
  • Page 130 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Interleaved 2 of 5 Check Digit *No Check Char. I25CK20 Validate, But Don’t I25CK21 Transmit Validate, and Transmit I25CK22 Interleaved 2 of 5 Message Length Minimum (2 - 80) *4 I25MIN## Maximum (2 - 80) *80 I25MAX##...
  • Page 131 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Code 11 Default All Code 11 C11DFT 6-13 Settings *Off C11ENA0 6-13 C11ENA1 6-13 Code 11 Message Length Minimum (1 - 80) *4 C11MIN## 6-13 Maximum (1 - 80) *80 C11MAX## 6-13 Code 128...
  • Page 132 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry UPC-E0 Default All UPC-E UPEDFT 6-19 Settings UPEEN00 6-19 UPEEN01 6-19 UPC-E0 Expand *Off UPEEXP0 6-20 UPEEXP1 6-20 UPC-E0 Addenda Required Required UPEARQ1 6-20 *Not Required UPEARQ0 6-20 UPC-E0 Addenda Separator UPEADS1...
  • Page 133 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry EAN/JAN-8 Check Digit EA8CKX0 6-24 EA8CKX1 6-24 EAN/JAN-8 Addenda *2 Digit Addenda Off EA8AD20 6-25 2 Digit Addenda On EA8AD21 6-25 *5 Digit Addenda Off EA8AD50 6-25 5 Digit Addenda On EA8AD51 6-25...
  • Page 134 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Codablock A Default All Codablock A Settings CBADFT 6-29 *Off CBAENA0 6-29 CBAENA1 6-29 Codablock A Msg. Length Minimum (1 - 600) *1 CBAMIN### 6-30 Maximum (1 - 600) *600 CBAMAX### 6-30 Codablock F...
  • Page 135 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry QR Code Page QR Code Page (*3) QRCDCP## 6-35 Data Matrix Default All Data Matrix Settings IDMDFT 6-36 IDMENA1 6-36 IDMENA0 6-36 Data Matrix Msg. Length Minimum (1-3116) *1 IDMMIN#### 6-36 Maximum (1-3116) *3116...
  • Page 136 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Combination 2D Postal Codes InfoMail and British Post On POSTAL8 6-40 Intelligent Mail Bar Code and POSTAL20 6-41 Postnet with B and B’ Fields On Postnet and Postal-4i On POSTAL14 6-41 Postnet and Intelligent Mail Bar...
  • Page 137 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Postal Codes - Linear China Post (Hong Kong 2 of 5) Default All China Post (Hong CPCDFT 6-44 Kong 2 of 5) Settings *Off CPCENA0 6-44 CPCENA1 6-44 China Post (Hong Kong 2 of 5) Msg.
  • Page 138 9 - 20...
  • Page 139: Chapter 10 - Product Specifications

    Product Specifications YJ-HF600 Scanner Product Specifications Parameter Specification Mechanical Height 6.69 inches (170mm) Length 3.87 inches (98.2mm) Width 3.44 inches (87.4mm) Weight 11.99 ounces (340g) Electrical Input Voltage 5.+ 0.5VDC Operating Power 2.1W; 420 mA (typical) @ 5V Standby Power 0.55W;...
  • Page 140: Standard Connector Pinouts

    Standard Connector Pinouts Note: The following pin assignments are not compatible with legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty.
  • Page 141: Chapter 11 - Maintenance

    The interface cable is designed to be field replaceable. • Order replacement cables from Honeywell or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable.
  • Page 142: Troubleshooting A Yj-Hf600 Scanner

    Troubleshooting a YJ-HF600 Scanner The scanner automatically performs self-tests whenever you turn it on. If your scanner is not functioning properly, review the following Troubleshooting Guide to try to isolate the problem. Is the power on? Is the aimer on? If the aimer isn’t illuminated, check that: •...
  • Page 143: Symbology Charts

    Refer to Data Editing beginning on page 4-1 and Data Formatting beginning on page 5-1 for information about using Code ID and AIM ID. Linear Symbologies Honeywell Possible modifiers Symbology All Symbologies Codabar Code 11 Code 128 0, 1, 2, 4 Code 32 Pharmaceutical (PARAF) <...
  • Page 144: 2D Symbologies

    Honeywell Possible modifiers Symbology UPC-A UPC-A with Add-On UPC-A with Extended Coupon Code UPC-E UPC-E with Add-On UPC-E1 Add Honeywell Code ID 5C80 Add AIM Code ID 5C81 Add Backslash 5C5C Batch mode quantity 2D Symbologies Honeywell Possible modifiers Symbology...
  • Page 145: Ascii Conversion Chart (Code Page 1252

    Honeywell Possible modifiers Symbology British Post Canadian Post China Post InfoMail Intelligent Mail Bar Code Japanese Post KIX (Netherlands) Post Korea Post Planet Code Postal-4i Postnet ASCII Conversion Chart (Code Page 1252) In keyboard applications, ASCII Control Characters can be represented in 3 different ways, as shown below. The CTRL+X func- tion is OS and application dependent.
  • Page 146: Lower Ascii Reference Table

    Non-printable ASCII control Keyboard Control + ASCII (CTRL+X) Mode characters Windows Mode Control + X Mode On (KBDCAS2) Char Control + X Mode Off (KBDCAS0) CTRL + X CTRL + X function CTRL+ W CTRL+ X CTRL+ Y CTRL+ Z CTRL+ [ CTRL+ \ CTRL+ ]...
  • Page 147 Printable Characters (Continued) Character Character Character ⌂ Extended ASCII Characters CP 1252 ASCII Alternate Extended PS2 Scan Code ↑ € Ç 0x48 up arrow ↓ ü 0x50 down arrow → ‚ é 0x4B right arrow ← ƒ â 0x4D left arrow „...
  • Page 148 Extended ASCII Characters (Continued) CP 1252 ASCII Alternate Extended PS2 Scan Code ¯ » Ctrl Sequence with 1 Character 0x1D ° ░ ± ▒ ² ▓ ³ │ ´ ┤ µ ╡ ¶ ╢ · ╖ ¸ ╕ ¹ ╣ º...
  • Page 149: Iso 2022/Iso 646 Character Replacements

    (standard ASCII) Automatic National Character ISO/IEC 2022 2 (default) Replacement Binary Code page Default “Automatic National Character replacement” will select the below Honeywell Code Page options for Code128, Code 39 and Code 93. United States ISO/IEC 646-06 Canada ISO /IEC 646-121...
  • Page 150 Code Page Selection Method/Country Standard Keyboard Country Honeywell Code Page Option China ISO/IEC 646-57 Great Britain (UK) ISO /IEC 646-04 France ISO /IEC 646-69 Germany ISO/IEC646-21 Switzerland ISO /IEC 646-CH Sweden / Finland (extended Annex C) ISO/IEC 646-11 Ireland ISO /IEC 646-207...
  • Page 151 à â ç ê î ô é ù è û à â ç ê É ô é ù è û ⎯ ¥ ⎯ ¥ £ ˜ £ à ° ç § µ é ù è ¨ § Ä Ö Ü ä...
  • Page 152 Keyboard Key References 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 4B 50 55 5A 5F 64 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 4C 51 56 5B 60 65 1F 20 21 22 23 24 25 26 27 28 29...
  • Page 153 Sample Symbols UPC-A 0 123456 7890 Interleaved 2 of 5 1234567890 EAN-13 9 780330 290951 Code 128 Code 128 Code 39 Codabar BC321 A13579B Code 93 123456-9$ Code 2 of 5 123456 Matrix 2 of 5 RSS-14 6543210 (01)00123456789012...
  • Page 154 Sample Symbols PDF417 Car Registration Postnet Code 49 Zip Code 1234567890 Data Matrix Test Symbol QR Code Numbers Aztec MaxiCode Package Label Micro PDF417 Test Message Test Message...
  • Page 155 Programming Chart...
  • Page 157 Programming Chart Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
  • Page 158 Honeywell YJ-HF600-UG Rev A 2/16...

Table of Contents