Environmental Specifications - Dell VxRail VP-760 Manual

Table of Contents

Advertisement

Environmental specifications

This section provides the physical and environmental specifications for the VxRail VP-760. For additional information about
environmental certifications, see the
The following table describes the continuous operation specifications for ASHRAE A2:
Temperature
Temperature range for
altitudes <= 900 m (<=
2953 ft)
Humidity percent range
(non-condensing always)
Operational altitude de-
rating
The following table describes the common environmental specifications for ASHRAE A2:
Temperature
Maximum temperature gradient (applies to both
operation and non-operation)
Non-operational temperature limits
Non-operational humidity limits
Maximum non-operational altitude
Maximum operational altitude
*Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
The following table describes the maximum vibration specifications:
Maximum vibration
Operating
Storage
The following table describes the maximum shock pulse specifications:
Maximum shock pulse
Operating
Storage
Particulate and gaseous contamination specifications
When the levels of particulate or gaseous pollution exceed the specified limitations and result in equipment damage or failure,
you must rectify the environmental conditions. The customer is responsible for the remediation of environmental conditions.
To avoid damage to equipment or failure due to particulate or gaseous contamination, consider the limitations specified in the
following tables:
24
Technical specifications
Product Environmental
Specifications
10–35°C (50–95°F) with no direct sunlight on the equipment
8% RH with -12°C (10.4°F) minimum dew point to 80% RH with 21°C (69.8°F) maximum dew
point
Maximum temperature is reduced by 1°C/300 m (1.8°F/984 ft) above 900 m (2953 ft)
Specifications
20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15
minutes), 5°C in an hour* (9°F in an hour) for tape hardware
-40 to 65°C (-40 to 149°F)
5% to 95% RH with 27°C (80.6°F) maximum dew point
12,000 meters (39,370 feet)
3,050 meters (10,006 feet)
Specifications
0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations)
1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Specifications
Six consecutively performed shock pulses in the positive and negative x, y, and z axis of 6
G for up to 11 ms
Six consecutively performed shock pulses in the positive and negative x, y, and z axis
(one pulse on each side of the system) of 71 G for up to 2 ms
Datasheet.