Summary of Contents for Oilon OilonCooling Cs4

  • Page 1 M8014 2337EN 11 September 2023 Installation and operation manual OilonCooling Cs Read these instructions carefully before installation, use, or maintenance...
  • Page 3: Table Of Contents

    Contents Introduction Safety notice and warnings................ 3 Delivery contents..................4 Installation Installing cooling unit.................. 6 Pipe installation................... 7 Electrical installation..................8 Operation Remote control....................9 General functions..................10 Setting the time..................10 Resetting the cooling unit................. 10 Adjusting room temperature..............11 Operating modes..................11 Selecting fan speed.................. 11 Setting a timer...................11 Turbo function...................
  • Page 4 2 (20) M8014 2337EN...
  • Page 5: Introduction

    1 Introduction 1.1 Safety notice and warnings Read these instructions carefully before installation, commissioning, operation, or maintenance of the device. The given instructions must be followed. Throughout this manual, the following symbols are used to point out very important information: Use special caution.
  • Page 6: Delivery Contents

    Use only fuses with the correct rating. Do not push items into the air inlet or outlet when the cooling unit is in operation, as this may result in an injury or damage to the equipment. Do not direct the air flow directly towards people. To avoid slipping, keep floor surfaces dry, and seal off or report any leaks that you detect.
  • Page 7 Removing the packaging Remove the cardboard packaging from around the product. Check the unit for transportation damage. If there is damage, report the damage immediately to the carrier who delivered the unit. M8014 2337EN 5 (20)
  • Page 8: Installation

    2 Installation 2.1 Installing cooling unit Place the cooling unit as high as possible. Cold air flows downwards. If you bring the pipes to the unit through a wall behind the unit, create a passthrough for the pipes. The dimensions required for locating the pass through are indicated on the cooling unit mounting plate.
  • Page 9: Pipe Installation

    1. Lift the top edge of the cooling unit to the hooks in the mounting plate. 2. Press the bottom edge of the cooling unit against the mounting plate, locking it in place. Opening the front grille 1. Remove the screw caps from top of the fastening screws (pos. S). 2.
  • Page 10: Electrical Installation

    Condensate drain installation Install the condensate drain with a slight slope away from the cooling unit. Make sure that air pockets cannot form in the drain line. ● Insulate the condensate drain line. ● If condensate is led directly to a drain, a water seal is required in the condensate drain line.
  • Page 11: Operation

    3 Operation 3.1 Remote control Press only one button at a time. Pressing two or more buttons simultaneously may cause a malfunction. The cooling unit will beep when it has received a signal from the remote control. If the signal does not reach the unit for some reason, there will be no beep. Layout Pos.
  • Page 12: General Functions

    3.2 General functions Power On/Off To turn the unit on or off, press the Power On/Off button. When switched on, the unit will operate with the settings shown on the remote control’s screen. Screen brightness adjustment To change the screen brightness, press the DIM button. Keylock To lock the remote control keys, press and hold the DIM button (with the key icon next to it) for two seconds.
  • Page 13: Adjusting Room Temperature

    3.5 Adjusting room temperature Set the room temperature with the arrow buttons. Available temperature range: 18–30 °C. The set room temperature will be shown on the remote control screen. 3.6 Operating modes To scroll between different operating modes, press the Mode button repeatedly. Mode Description COOL...
  • Page 14: Turbo Function

    ● Pressing an arrow button will move the time 10 minutes forwards or backwards. To browse through numbers faster, keep the arrow button pressed. 3. Press the timer On button. The time will stop blinking. Setting the timer to switch the unit off 1.
  • Page 15: Sleep Function

    3.12 Sleep function The Sleep function automatically adjusts the room temperature setting one hour after the function has been activated. Activate or deactivate the SLEEP function by pressing the Sleep button. ● In COOL mode, the unit will automatically increase the set temperature by one degree after one hour.
  • Page 16: Maintenance

    4 Maintenance 4.1 Tasks at the start and end of the heating season At the start of the cooling season ● Install new batteries in the remote control. ● Check that the cooling unit is installed correctly. ● Check that the cooling unit’s air flow is free of obstructions. ●...
  • Page 17: Cleaning The Cooling Unit

    If the air filter is not installed properly, the cooling unit may not start. 4.3 Cleaning the cooling unit Preparations 1. Shut down the cooling unit with the remote control. 2. Disconnect power from the unit’s main switch or detach the unit’s power cable. 3.
  • Page 18: Troubleshooting

    Cleaning Carefully clean the air outlet and fan. If the air outlet or fan are dirty, clean with a moist towel. If necessary, use mild detergent. Dry with a dry cloth. Do not use solvents or polishing compounds for cleaning. Reattaching the deflectors 1.
  • Page 19: Technical Data

    5 Technical data 5.1 Technical data Cooling capacity, kW* 3.76 6.34 Max. input power, fan, W Coefficient of performance** 80–200 20–300 Cooled floor area, m Weight, kg Placement Wall Wall *Cooling capacity in recommended installation conditions, brine inlet temperature: +7 °C, indoor temperature: +27 °C.
  • Page 20: Wiring Diagram

    5.3 Wiring diagram 5.4 Terms of sale and warranty SUOMEN LÄMPÖPUMPPUTEKNIIKKA OY’S TERMS OF SALE AND WARRANTY FOR PRODUCTS IN THE OILONCOOLING SERIES General In these general terms of sale and warranty, ‘the Supplier’ refers to Suomen Lämpöpumpputekniikka Oy (Business ID: 0511150-0, “the Supplier”), ‘the Customer’ to the company, entity, or person who has entered into this contract or to whom the order confirmation has been addressed (“the Customer”), and ‘Products’...
  • Page 21 Term of delivery The term of delivery is Ex Works the Supplier’s place of operations in Lapua (Incoterms 2000), unless separately agreed between the parties in writing. Title The title to the Products is transferred to the Customer after the Supplier has received full payment for the Products.
  • Page 22 Limitation of liability The Supplier shall not, under any circumstances, be liable for indirect damages, excluding damages that the Supplier has caused with willful intent or gross negligence. The Supplier’s maximum liability is always limited to the value of the delivered Products.
  • Page 24 Contact information of Oilon dealer: OILON GROUP P.O. Box 5 FI-15801 LAHTI FINLAND Tel: +358 3 85 761 Fax: +358 3 857 6239 Email: info@oilon.com Date of installation: www.oilon.com...