Close the side cover by pressing the round projections near the side cover open
2
button. The misfeed (
up.

B Misfeed in the fusing area

Lower the fusing unit release lever.
1
Gently remove the misfed paper from under the fusing unit as shown in the illustration.
2
If the paper cannot be removed, proceed to "C Misfeed in the transport area".
The fusing unit is hot. Do not touch the fusing unit when removing misfed
paper. Doing so may cause a burn or other injury.
Do not touch the surface of the drum (green portion) of the drum cartridge
when removing the misfed paper. Doing so may cause smudges on copies.
Do not remove the misfed paper from above the fusing unit. Unfixed toner on
the paper may stain the paper transport area, resulting in smudges on copies.
) indicator will go out and the ready (
Fusing unit release lever
MISFEED REMOVAL
) indicator will light
6