  • Page 1 USER GUIDE & SERVICE MANUAL Model: UHNP115-SS01B...
  • Page 2 USER GUIDE & SERVICE MANUAL u-line.com Table of Contents Service Intro Troubleshooting Safety Wire Diagram Safety and Warning Product Liability Disposal And Recycling Warranty Claims Parts Installation Ordering Replacement Parts Environmental Requirements R600a Specifications Electrical System Diagnosis Guide Cutout & Product Dimensions...
  • Page 3: Product Information

    U-Line Customer Care must be contacted immediately at +1.414.354.0300. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
  • Page 4: Safety And Warning

    USER GUIDE u-line.com Safety and Warning DANGER NOTICE This unit contains R600a (Isobutane) which is a Please read all instructions before installing, flammable hydrocarbon. It is safe for regular operating, or servicing the appliance. use. Do not use sharp objects to expedite defrosting.
  • Page 5: Disposal And Recycling

    USER GUIDE u-line.com Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside. If the unit is being removed from service for disposal,...
  • Page 6: Environmental Requirements

    USER GUIDE u-line.com Environmental Requirements This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements. This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce...
  • Page 7 USER GUIDE u-line.com Electrical WARNING SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
  • Page 8: Cutout & Product Dimensions

    14 ⁄ ” (379 mm) PREPARE SITE Your U-Line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed, 28”...
  • Page 9: Side-By-Side Installation

    USER GUIDE u-line.com Side-by-Side Installation Hinge-by-Hinge Installation (Mullion) When installing two units hinge-by-hinge, 13/16" (22 mm) OTHER SITE REQUIREMENTS is required for integrated models. Additional space may be Side-by-Side Installation needed for any knobs, pulls or handles installed. Units must operate from separate, properly grounded electrical receptacles placed according to each unit’s...
  • Page 10: Water Hookup

    Use new hose set. Do not reuse old hose set. • Water Treatment Options ◦ TDS between 400-600 and/or hardness between 13-20 can be treated by U-Line’s in-line water filter accessories available at u-line.com or your local CAUTION dealer:  ULALINEFILTER — Standard Turn off water supply and disconnect electrical supply to unit prior to installation.
  • Page 11 USER GUIDE u-line.com Thread water line through back panel hole (with bushing). Locate water valve inlet and connect to valve. Turn on water supply and check for leaks. Reinstall back panel. Water Hookup...
  • Page 12: Gravity Drain

    DRAIN CONNECTION CAUTION With Trap and Vent Proper Drain If your U-Line unit did not come with a factory installed drain pump you must use a gravity A gravity drain may be used if: style drain connection. For assistance in Drain line has at least a 1”...
  • Page 13: Factory Installed Drain Pump

    Air Gap (Optional Hook-Up) requirements for a gravity drain, you may have ordered a pre-installed U-Line P60 drain pump. Waste If you need to install a P60 drain pump into your unit, see Shut-Off...
  • Page 14: Anti-Tip Bracket

    USER GUIDE u-line.com Anti-Tip Bracket Surrounding area (Top view) Use one of the methods below to secure the unit CABINET/COUNTER ANTI-TIP INSTALLATION (For built-in applications) Back of unit Back wall Slide unit out so screws on front of unit are easily accessible.
  • Page 15: General Installation

    USER GUIDE u-line.com General Installation INSTALLATION Plug in the power/electrical cord. LEVELING INFORMATION Gently push the unit into position. Be careful not Use a level to to entangle the cord or water and drain lines, if confirm the unit is applicable.
  • Page 16: Grille Installation

    USER GUIDE u-line.com Grille Installation REMOVING AND INSTALLING GRILLE WARNING Disconnect electric power to the unit before removing the grille. When using the unit, the grille must be installed. WARNING DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.
  • Page 17: Door Swing

    USER GUIDE u-line.com Door Swing Wall For Integrated models that are installed adjacent to a wall, 1/2" (13 mm) 1/2" (13 mm) clearance is recommended from wall on hinge side to allow the door to open 90°. Allow for additional space for any knobs or pulls installed on the integrated panel/frame.
  • Page 18 USER GUIDE u-line.com Door Stop Your U-Line unit was shipped to you with the optional 90° pin. Your unit’s door(s) will open 115° straight from the factory. If you would like the door stop at 90°, follow these instructions. NOTICE If your unit is already undercounter, it will need to be moved out to access the hinge.
  • Page 19: Door Alignment And Adjustment

    USER GUIDE u-line.com Door Adjustments REVERSING THE DOOR Open door. DOOR ALIGNMENT AND ADJUSTMENT Using T-25 Torx bit loosen screw #1 and remove screw Align and adjust the door if it is not level or not sealing #2 on top and bottom hinge. Slide and remove the properly.
  • Page 20: First Use

    Initial startup requires no adjustments. See CONTROL OPERATION section for more details. NOTICE U-Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line.
  • Page 21: Control Operation

    USER GUIDE u-line.com Control Operation CONTROL FUNCTION GUIDE FUNCTION COMMAND NOTES ON/OFF Press and release Unit will immediately turn On or OFF Adjust ice density See “Ice” section The o F / o C symbol will flash briefly after 5 seconds.
  • Page 22 The factory default ice setting is 0, which produces a firm and compact ice nugget. U-Line’s exclusive U-Choose™ ice adjustability feature allows you five levels of adjustment from 0 to -5. At -5 the ice is soft and chewable.
  • Page 23: Airflow And Product Loading

    USER GUIDE u-line.com Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit will not perform as expected. Do not install the unit behind a door.
  • Page 24: Exterior Cleaning

    USER GUIDE u-line.com Cleaning Integrated Models To clean integrated panels, use household cleaner per the EXTERIOR CLEANING cabinet manufacturer’s recommendations. Vinyl Clad (Black or White) Models INTERIOR CLEANING Clean surfaces with a mild detergent and warm water solution. Do not use solvent-based or abrasive cleaners.
  • Page 25 ◦ Register your product at u-line.com and receive a free cleaning kit - ULANUGGETCLEANKIT** (cleaner, hose, & funnel) Dispenser ** available for purchase at u-line.com or your local dealer Tube Need more cleaner? Visit u-line.com CAUTION Press and release will appear in the display Use only SafeCLEAN Plus™...
  • Page 26 USER GUIDE u-line.com When appears in the display, 3 soft tones will sound, indicating the cleaning phase is complete a. Remove and discard water filter if applicable by rotating 1⁄4 turn counterclockwise. b. Use the remaining cleaning solution to wipe the manifold and surrounding area.
  • Page 27: Cleaning Condenser

    USER GUIDE u-line.com Cleaning Condenser INTERVAL - EVERY SIX MONTHS To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depending on environmental conditions, more or less frequent cleaning may be necessary.
  • Page 28: Extended Non-Use

    USER GUIDE u-line.com Extended Non-Use For questions regarding winterization, please call VACATION/HOLIDAY, PROLONGED SHUTDOWN U-Line at 414.354.0300. The following steps are recommended for periods of extended non-use: CAUTION Remove all consumable content from the unit. Damage caused by freezing temperatures is not covered by the warranty.
  • Page 29: Before Calling For Service

    BEFORE CALLING FOR SERVICE • Condenser Fan: Air moving through a condenser may be heard. If you think your U-Line product is malfunctioning, read the CONTROL OPERATION section to clearly understand the • Automatic Defrost Drain Pan: Water may be heard function of the control.
  • Page 30: Checking Product Temperature

    USER GUIDE u-line.com u-line.com CHECKING PRODUCT TEMPERATURE Causes which affect the internal temperatures of the cabinet include: • Temperature setting. • Ambient temperature where installed. • Installation in direct sunlight or near a heat source. • The number of door openings and the time the door is open.
  • Page 31: Wire Diagram

    USER GUIDE u-line.com Wire Diagram Wire Diagram...
  • Page 32: Product Liability

    The part that caused the damage must be returned to U-Line in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
  • Page 33: Warranty Claims

    Claims must be submitted online at • Final billing - Remodel www.U-LineService.com Warranty parts will be shipped at no charge after U-Line • 60 day submittal deadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part description.
  • Page 34 USER GUIDE u-line.com Parts UHNP115-SS01B ACCESS PANEL 80-55369-00 BACK PANEL 80-55257-00 COMPRESSOR 80-55211-00 CONDENSER ASSY 80-55379-00 CONDENSER FAN BLADE 80-54066-00 CONDENSER FAN MOTOR 80-54138-00 COVER W/HOOK 80-54332-00 DISPLAY ASSEMBLY 80-55214-00 DOOR 80-55370-00 DRAIN PUMP 80-54147-00 DRIER 80-54055-00 DUMP VALVE 80-55232-00...
  • Page 35 USER GUIDE u-line.com Parts NUGGET ICE EVAPORATOR GEAR MOTOR ASSEMBLY 80-55371-01 MAIN HOUSING W/SEAL & SCREWS 80-55371-02 AUGER W/FRONT SEAL 80-55371-04 ICE COMPRESSION NOZZLE ASSY 80-55371-05 FRONT SEAL AND O-RING 80-55371-06 EVAPORATOR W/FLANGES & O-RING 80-55371-07 HOUSING, BUSHING 80-55371-08 HARDWARE KIT, GEAR MOTOR 80-55371-09 RESERVOIR &...
  • Page 36: Ordering Replacement Parts

    Warranty parts will be shipped at no charge after U-Line confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
  • Page 37 Never use a torch on a fully charged refrigeration system. Never substitute U-Line OEM replacement parts or methods of construction. R-600a must be stored and transported in Technician must observe all federal, state and local laws regarding refrigerants.
  • Page 38 USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE R-600A SPECIFICATIONS/LABELING WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians permitted to service R-600a equipped products.
  • Page 39: Leak Detection

    USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed.
  • Page 40 USER GUIDE USER GUIDE u-line.com u-line.com SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure).
  • Page 41: System Diagnosis Guide

    USER GUIDE u-line.com System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold...
  • Page 42: Compressor Specifications

    USER GUIDE u-line.com Compressor Specifications FMXA9C REFRIGERANT R600A DANGER VOLTAGE 230 VAC FREQUENCY 43-134 Hz START WINDING 20 Ohm at 77 Electrocution can cause death or serious injury. RUN WINDING 20 Ohm at 77 Burns from hot or cold surfaces can cause serious injury.
  • Page 43: Troubleshooting - Extended

    DC outputs located on the relay/power board. Included in this section are some diagnostic tips and of course, if additional help is required, please contact the U-Line Corp, “Customer Care Facility” at +1.414.354.0300 for assistance. NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components.
  • Page 44: Main Control

    Go to component testing and turn on fill valve and verify 120V at the valve. Low Ice Dirty evaporator, dirty condenser, faulty Clean the evaporator using U-Line cleaner, clean the Production bin thermistor condenser coil if needed, check bin thermistor reading in service mode.
  • Page 45: Error Codes

    USER GUIDE u-line.com Relay & DC Outputs PLUNGER SWITCH A plunger switch is used to monitor door state. When the One of the primary functions of the main control is to door is closed it comes into contact with the plunger which operate the multiple relay and DC outputs during each closes a circuit which turns the light and display off.
  • Page 46 If TDS is acceptable, unit must be cleaned and APPENDIX any leakage addressed with a seal kit. (U-Line E11: Sensor in base near fan detecting water service part # 80-55371-13) This sensor is designed to detect water escaping the Area in Front of Sensors (Condenser Side) is Wet product due to any type of malfunction inside the machine.
  • Page 47 USER GUIDE u-line.com If unit fills, the float switch is malfunctioning and d. Check compressor operation. needs to be replaced (part # 80-55538-00). • If unit is not cooling or compressor is not If unit is 3 Class product, enter service mode and operating, diagnose and fix system problem.
  • Page 48 USER GUIDE u-line.com Control Operation-Service CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY/OPTIONS UI BUTTON LAYOUT and release Unit will immediately Press ON/OFF turn ON or OFF Sabbath Mode See “Sabbath Mode” section Silent Mode (ice production Display will shw “3H” Hold...
  • Page 49: View Error Log

    USER GUIDE u-line.com SERVICE MODE GUIDE SERVICE MODE GUIDE 0. Exit THERMISTOR 1 - BIN 1. Thermistor 1 temperature not including offsets. This shows the pure thermistor reading with no off- 2. Thermistor 2 temperature not including offsets. sets taken into account.
  • Page 50 USER GUIDE u-line.com 15. CLEAR ERROR LOG To clear errors, press and hold (5 seconds) when CLR is flashing. 16. THERMISTOR - 1 DIFFERENTIAL This number should not be adjusted 17. Does not apply to this model 18. Does not apply to this model 19.
  • Page 51: Model List

    MODEL NUMBER 1. Disconnect the unit from power source. 2. Push and hold the U-Line button. 3. While still holding the U-Line button, plug the unit into the appropriate power source. 4. When the flashing digits appear (3-5 seconds), use the up and down arrow buttons to select the appropriate model number*.
  • Page 52 USER GUIDE u-line.com Control Operation-Service...
  • Page 53 USER GUIDE u-line.com Thermistor Thermistor Resistance Data Nominal Resistance Thermistors are used for various temperature readings. Temp (F) Temp (C) (OHMS)* Thermistors provide reliable temperature readings using a 169157 resistance which varies based on surrounding temperatures. 121795 If a faulty thermistor is suspected, it may be tested using 88766 an accurate ohmmeter.
  • Page 54 For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U-Line under the above warranty must be performed by a U-Line factory authorized servicer, unless otherwise specified by U-Line.