8. SERVICE FACTORY MODE

8.1 OUTLINE OF THE SERVICE FACTORY

8.1.1 FACTORY HIERARCHICAL TABLE

A
Large Item
Middle Item
8.2.1 INFORMATION
8.2.1.1 VERSION (1)
8.2.1.2 VERSION (2)
8.2.1.3 MAIN NG
8.2.1.4 TEMPERATURE
8.2.1.5 HOUR METER
8.2.1.6 HDMI SIGNAL INFO 1
8.2.1.7 HDMI SIGNAL INFO 2
8.2.1.8 VDEC SIGNAL INFO
8.2.2 PANEL FACTORY (+)
8.2.2.1 PANEL INFORMATION
8.2.2.2 PANEL WORKS
B
8.2.2.3 POWER DOWN
8.2.2.4 SHUT DOWN
8.2.2.5 PANEL-1 ADJ (+)
8.2.2.6 PANEL-2 ADJ (+)
C
8.2.2.7 PANEL REVISE (+)
8.2.2.8 ETC. (+)
D
8.2.2.9 RASTER MASK SETUP (+)
8.2.2.10 PATTEN MASK SETUP (+)
8.2.2.11 COMBI MASK SETUP (+)
E
8.2.3 OPTION
8.2.3.1 EDID WRITE MODE <=>
8.2.3.2 CH PRESET <=>
8.2.4 INITIALIZE
8.2.4.1 SYNC DET (+)
8.2.4.2 SG MODE <=>
8.2.4.3 SG PATTERN <=>
8.2.4.4 SIDE MASK LEVEL (+)
8.2.4.5 FINAL SETUP (+)
8.2.4.6 CVT AUTO <=>
8.2.4.7 HDMI INTR POSITION (+)
F
32
1
2
Small Item
CLEAR <=>
X-SUS B <=>
Y-SUS B <=>
Y-SUSTAIL T1 <=>
Y-SUSTAIL T2 <=>
Y-SUSTAIL W <=>
XY-RST W1 <=>
XY-RST W2 <=>
VOL SUS <=>
VOL OFFSET <=>
VOL RST P <=>
SUS FREQ. <=>
R-HIGH <=>
G-HIGH <=>
B-HIGH <=>
R-LOW <=>
G-LOW <=>
B-LOW <=>
ABL <=>
R-LEVEL <=>
G-LEVEL <=>
B-LEVEL <=>
BACKUP DATA <=>
DIGITAL EEPROM <=>
PD INFO. <=>
SD INFO. <=>
HR-MTR INFO. <=>
PM/B1-B5 <=>
P COUNT INFO. <=>
MAX TEMP. <=>
MASK OFF
RST MASK 01 <=>
• • •
RST MASK 24 <=>
MASK OFF
PTN MASK 01 <=>
• • •
PTN MASK 39 <=>
MASK OFF
CMB MASK 01 <=>
• • •
CMB MASK 10 <=>
R MASK LEVEL <=>
G MASK LEVEL <=>
B MASK LEVEL <=>
DATA RESET <=>
INTR-POS1 (0x75) <=>
INTR-POS2 (0x76) <=>
INTR-POS3 (0x77) <=>
INTR-POS4 (0x78) <=>
Notes : the marked part is changed.
PDP-507XC
2
3
Variable / Adjustment Range
OFF <=> ON
120 to 136
120 to 136
120 to 136
120 to 136
120 to 136
120 to 136
120 to 136
000 to 255
000 to 255
000 to 255
MODE 1 to MODE 8
000 to 511
000 to 511
000 to 511
000 to 999
000 to 999
000 to 999
000 to 255
LV-0 to LV-7
LV-0 to LV-7
LV-0 to LV-7
NO OPRT <=> TRANSFER or ERR
NO OPRT <=> DELETE/REPAIR
NO OPRT <=> CLEAR
NO OPRT <=> CLEAR
NO OPRT <=> CLEAR
NO OPRT <=> CLEAR
NO OPRT <=> CLEAR
NO OPRT <=> CLEAR
<=> 48V <=> 50V <=> 60V <=>
60P <=> 70P <=> 72V <=> 75V <=>
<=> 48V <=> 50V <=> 60V <=>
60P <=> 70P <=> 72V <=> 75V <=>
<=> 48V <=> 50V <=> 60V <=>
60P <=> 70P <=> 72V <=> 75V <=>
SG OFF <=> • • •
SG PATTERN <=> COLOR BAR 1 • • •
000 to 255
000 to 255
000 to 255
OFF <=> ON
000 to 255
000 to 255
000 to 255
000 to 255
3
4
Remarks
Equivalent to XSB
Equivalent to YSB
Equivalent to YTG
Equivalent to YTB
Equivalent to YTW
Equivalent to RSW
Equivalent to RYW
Equivalent to VSU
Equivalent to VOF
Equivalent to VRP
Equivalent to SFR
Equivalent to PRH
Equivalent to PGH
Equivalent to PBH
Equivalent to PRL
Equivalent to PGL
Equivalent to PBL
Equivalent to ABL
Equivalent to RRL
Equivalent to RGL
Equivalent to RBL
Equivalent to BCP
Equivalent to FAJ/UAJ
Equivalent to CPD
Equivalent to CSD
Equivalent to CHM
Equivalent to CPM
Equivalent to CPC
Equivalent to CMT
Equivalent to MKS+S00
Equivalent to MKS+S51
• • •
Equivalent to MKS+S74
Equivalent to MKS+S00
Equivalent to MKS+S01
• • •
Equivalent to MKS+S39
Equivalent to MKC+S00
Equivalent to MKC+S01
• • •
Equivalent to MKC+S10
Exclusively used for
production line
for the technical analysis
Exclusively used for
technical analysis
(details omitted)