Siemens SIMATIC Ident RF340R02 System Manual page 80

Table of Contents

Advertisement

Planning the RF300 system
4.3 Installation guidelines
Reader RF350R with ANT 1 and with ISO transponders (MDS D)
Table 4- 41
Transponder
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
80
Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 1
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
1)
On metal; distance 25 mm
Flush-mounted in metal;
distance all round 50 mm
Without metal
1)
On metal; distance 30 mm
Flush-mounted in metal;
distance all round 100 mm
Without metal
1)
On metal; distance 10 mm
Without metal
On metal; distance 25 mm
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 25 mm
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
distance all round 25 mm
Without metal
1)
On metal; distance 30 mm
Flush-mounted in metal;
distance all round 100 mm
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
ANT 1 without
ANT 1 on metal
metal
100
85
70
60
60
45
100
95
85
85
85
80
100
85
85
75
80
70
100
90
95
85
95
85
100
95
85
85
100
85
90
80
100
85
85
75
75
65
100
90
85
80
100
85
90
80
80
75
100
90
95
85
95
85
100
90
80
70
65
60
System Manual, 07/2017, C79000-G8976-C345-07
ANT 1 mounted
in metal
(40 mm all-
round)
80
65
45
85
80
50
85
75
70
85
85
85
90
80
85
75
80
75
65
85
80
85
80
65
85
85
85
85
65
60
SIMATIC RF300

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ident rf300Simatic ident rf310r02

Table of Contents