Product Information; Scope Of Delivery; 180 Sl Dimensions And Minimum Clearances - Bosch CS5800iAW 180 MCP Installation And Maintenance Instructions Manual

Pre plumbed cylinder
Hide thumbs Also See for CS5800iAW 180 MCP:
Table of Contents

Advertisement

Product Information

After installation the Benchmark log book and included commissioning
sheets must be completed and left along with these instructions with the
householder for future reference.
Any water distribution and central heating installation must comply with
the relevant recommendations of the current version of Regulations and
British Standards listed below:
Building Regulations
IEE Requirements for Electrical Installations (BS 7671)
Water Regulations
Manual Handling Operations Regulations.
British Standards
Where no specific instruction is given, reference should be made to the
relevant British Standard codes of Practice.
• BS7074:1
– Code of practice for domestic and hot water supply
• BS7593
– Treatment of water in domestic hot water central heating systems
• BS6798
• BS5449
• BS5540:1
• BS5540:2
• CP331:3
• BS8558
• BS7671
– IET Wiring Regulations
Health and Safety Document No. 635
4
3
Product Information
3.1

Scope of delivery

3.1.1
Scope of delivery
1
Fig. 1
Standard delivery
1. Indoor unit with pre-assembled filling link* (dotted outlined
enlargement)
Accessory pack
2. Hardware pack
3. Strap to lift the cylinder
4. Expansion vessel for domestic water 18L
5. Outdoor temperature sensor
6. Documentation
7. ErP label
8. Connect-Key K30
*The filling link is used only for installation and re pressuring, store the
braided hose close to indoor unit after system filling
Model Name
Cylinder Size/ Description
CS5800iAW 180 MCP
180 Litre Slim line (180 SL)
CS5800iAW 210 MP
210 litre (210 L)
CS5800iAW 250 MP
250 litre (250 L)
Table 2 Model name, description
3.1.2

180 SL Dimensions and minimum clearances

• The following details cover the installation, service and maintenance
clearances for the product.
Note the dimensions and minimum clearances in the figures for all three
directions carefully. Note also the position of the door if installed in a
cupboard.
Pre plumbed cylinder – 6 721 852 928 (2023/04)
Accessory pack (box)
5
2
6
3
7
4
8
0010048061-001

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs5800iaw 210 mpCs5800iaw 250 mp