Mechanical Stability (In Operation); Cable Lengths - Siemens SIMATIC NET SCALANCE XC-200 Series Operating Instructions Manual

Industrial ethernet switches
Table of Contents

Advertisement

Technical specifications
Housing, dimensions and weight
Design
Housing material
Degree of protection
Dimensions (W x H x D)
Weight
Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
Note the wiring rules (Page 51).
1)
7.7

Mechanical stability (in operation)

Mechanical stability (in operation)
Device
SCALANCE XC206-2 (ST/BFOC)
SCALANCE XC206-2 (SC)
SCALANCE XC206-2SFP
SCALANCE XC208
SCALANCE XC216
SCALANCE XC224
7.8

Cable lengths

The cable lengths listed below apply to the SCALANCE XC-200.
Cable
IE TP torsion cable
with IE FC Outlet RJ-45 + 10 m TP cord
IE TP torsion cable
with IE FC RJ-45 Plug 180
SCALANCE XC-200
Operating Instructions, 12/2017, C79000-G8976-C442-03
compact
Basic housing
Front cover
IP20
120 x 145 x 125 mm
880 g
● Wall mounting
● Installation on a DIN rail
● Mounting on an S7-300 standard rail
● Mounting on an S7-1500 standard rail
> 41 years
IEC 60068-2-27 shock
15 g, 11 ms duration
6 shocks per axis
Die cast aluminum, powder coated
Polycarbonate (PC-GF10)
IEC 60068-2-6 vibration
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
Permitted cable length
0 to 45 m
+ 10 m TP cord
0 to 55 m
Technical specifications
7.8 Cable lengths
67