14
shall be carried out prior to returning the compressor to the suppliers. Only
electric heating to the compressor body shall be employed to accelerate
this process. When oil is drained from a system, it shall be carried out safely.

Technical specification

Model
Power Supply
Energy Efficiency Class
Running Power Consumption
Standby Power Consumption (W)
Cooling Capacity (W)
Heating Capacity (W)
Noise Level dB(A) (Fan speed: High/Medium/Low)
Air Flow (High/Medium/Low) (m³/h)
Operating Temperature Range (°C)
Room Size (m²)
Size (W x D x H in mm)
Weight (kg)
Refrigerant
Technical specifications are subject to change without notice.
Cooling
Heating
Cooling (W)
Heating (W)
UL-C10EA-W
220 – 240V AC, 50Hz
220 – 240V AC, 50Hz
A+
N/A
935
N/A
0,5
2900
N/A
65/64/62
385/355/325
16 ~ 30
13 ~ 19
393 x 425 x 804
32,5
R290
UL-C12EA-W
UL-Y12EA-W
220 – 240V AC, 50Hz
A
N/A
1345
N/A
0,5
3520
N/A
65/64/62
385/355/325
385/355/325
16 ~ 30
16 ~ 23
393 x 425 x 804
393 x 425 x 804
34,5
R290
A
A+
1345
1190
0,5
3520
3100
65/64/62
16 ~ 30
16 ~ 23
35,0
R290