Noise filter
To eliminate AC line noise, a noise filter should be installed at the AC input terminal on the IDD
power supply unit. The specification of this noise filter is as follows:
Attenuation: 40 dB or more at 10 MHz
Circuit construction: T-configuration as shown in Figure 4.8 is recommended.
4.3

Connection Requirements

4.3.1

Connector

Figure 4.9 shows the locations of interface connector.
Interface connector (CN1)
(Including power supply connector)
C141-E213
Figure 4.8
AC noise filter (recommended)
Figure 4.9
Connector location