INTRODUCTION
The ADEMCO 5800RL is a Wireless Relay Module that
enables use of remote sounders and/or remote arm/disarm
indicators using two relays activated by wireless signals from
the LYNX control (see Figure 1). The 5800RL can also send
tamper and supervision signals to the LYNX if so
programmed. The 5800RL is compatible with LYNX controls
having software versions 9.0 or higher. Refer to the LYNX
control installation and setup guide for software compatibility
and zone programming information.
MODULE'S 2
RELAYS ARE
ACTIVATED BY
SYSTEM
CONDITIONS
OFF
AWAY
STAY
AUX
Figure 1. Lynx Interface Diagram
MOUNTING LOCATION GUIDELINES
Use the following guidelines when selecting a mounting
location for the 5800RL Relay Module (see Figure 2):
Mount the 5800RL in a high location for best wireless
reception.
Do not mount the 5800RL on or near metal objects. This
decreases range and/or blocks wireless transmissions.
Locate the 5800RL at least 10 feet from any remote
keypad to avoid interference from the microprocessors in
those units.
To avoid voltage loss that occurs on long power lines,
mount the external power supply unit in close proximity to
the 5800RL.
Mounting, Wiring, and Setup
IMPORTANT: Before permanently mounting the 5800RL,
perform the setup procedure described in the Setting Up
the 5800RL section.
1. Remove the 5800RL's cover from the base (using a small
flat head screwdriver, insert screwdriver's tip in slot at top
of the cover and twist).
2. Using the 5800RL base as a template, position in the
desired location and mark the two mounting holes. See
Figure 2 for mounting hole locations.
3. Attach the 5800RL base using the fasteners supplied.
Screws and plastic anchors are suitable for a typical
installation, but you may use any two fasteners that
secure the base firmly to the mounting surface.
4. Connect relay and power wiring to the 5800kRL's
terminals. Refer to Figure 3 for a typical relay application.
All manuals and user guides at all-guides.com
INSTALLATION AND SETUP GUIDE
RELAY
MODULE
5800RL
TAMPER AND
SUPERVISION
SIGNALS SENT
TO CONTROL
5800RF-004-V0
ADEMCO 5800RL
Wireless Relay Module
The 5800RL can be powered from either an AC transformer
or DC power supply external power source connected to
terminals 7 and 8 (see Figure 3).
Power source ratings and connections are as follows:
Type
Rating
Connected to...
AC
9VAC, 15VA
terminals 7 and 8
DC
9VDC, 100mA
terminals 7 and 8
or
power connector.
NOTE: Use of power sources with higher or lower voltages
may result in damage or failure to operate properly. Non-
ADEMCO power supplies may have connectors installed.
Remove these connectors prior to attempting to connect
power supply to 5800RL.
RF INTERFERENCE
LED (RED)
1 - NC
2 - NO
RELAY A
3 - COM
4 - NC
5 - NO
RELAY B
6 - COM
7 - AC OR DC (+) IN
8 - AC OR DC ( ) IN
MOUNTING
HOLE
Figure 2. 5800RL Diagram
ADEMCO AD12612
AUX PWR SUPPLY
+
(12 VDC)
DC
_
OUT
AC
IN
+
_
1361
PWR SUPPLY
POWER SUPPLY
XFMR
BACKUP
16.5VAC
BATTERY 12VDC
Figure 3. Typical Sounder Wiring Installation
Setting Up the 5800RL
Refer to RELAY and LED Operation section and DIP Switch
(Figure 4) in order to set up the 5800RL as follows:
5. Set DIP switches 3-6 (Figure 4) to the appropriate House
ID (1-31). Make sure the House ID set by the DIP
switches matches that entered in the LYNX control.
6. If module supervision and/or tamper protection is desired,
program the 5800RL's tamper/supervisory loop (1) as a
zone and enroll its serial number.
Note the following when enrolling:
Zone Type = 5 (trouble by day/alarm by night)
Input Type = 3 (RF)
Loop Number = 1
K3790V1 6/07 Rev. A
Source Example
Ademco 1332
N7703
plugged
into
LED
(YELLOW)
MOUNTING
LED
LED
HOLE
(GREEN)
(RED)
ANTENNA 2
ON
OFF
1 2 3 4 5 6
TAMPER
DIP
SWITCH
SWITCH
5800RL-001-V1
+
SOUNDER
ANTENNA 2
1 - NC
RELAY A
2 - NO
3 - COM
4 - NC
RELAY B
5 - NO
6 - COM
7 - AC OR DC (+) IN
8 - AC OR DC ( ) IN
1 2 3 4 5 6
5800RL-005-V0
ON
OFF

Advertisement

loading

Summary of Contents for Honeywell ADEMCO 5800RL

  • Page 1 The 5800RL can be powered from either an AC transformer or DC power supply external power source connected to The ADEMCO 5800RL is a Wireless Relay Module that terminals 7 and 8 (see Figure 3). enables use of remote sounders and/or remote arm/disarm...
  • Page 2 OFF = no alarms present (NC contact connects interference (2) This device must accept any interference received, including to COM) interference that may cause undesired operation. 2 Corporate Center Drive, Melville, NY 11747 Copyright © 2007 Honeywell International Inc. ÊK3790V1UŠ www.honeywell.com/security K3790V1 6/07 Rev. A...