Relay control for external dispensing system
The washer-extractor is fitted with an adapter for an external dispensing
system. The external pumps are controlled by relays in the washer-extractor.
The dispensing containers must be filled with the correct detergent or additive
in the order specified.
Basic programmes
Cottons Hygiene
Cottons Uni.
Minimum iron
Delicates
Woollens
Quick wash
Silks
Shirts
Intensive wash
Outerwear
Proofing
Towelling
Household
Dark garments
Denim
R 1 = Relay 1 = Pre-wash
R 2 = Relay 2 = Main wash
R 3 = Relay 3 = Delicates / WetCare
R 4 = Relay 4 = Fabric softener/ WetCare or surface disinfectant
R 5 = Relay 5 = Disinfecting agent or floor cleaning agent
R 6 = Relay 6 = Proofing agent
* When selecting the target group Buildings maintenance.
** Dispense when temperature is reached.
30
Pre-
Main wash
wash
1st Signal
R 1
R 2
R 1
R 2
R 1
R 2
R 3
R 3
-
R 3
-
R 2
-
R 3
-
R 2
-
R 2
-
R 2
-
-
-
R 2
-
R 2
-
R 2
Main wash
Finishing
2nd Signal
R 5
R 4
R 5
R 4
-
R 4
-
R 4
-
R 4
-
R 4
-
R 4
-
R 4
-
R 4
-
R 6
-
R 6
R 5
R 4
-
R 4
-
R 4
*
*