Undamped Natural conditioning electronics should clamp the signal to excitation Wavelength 7.2 m (23.6 ft) or reference level when this occurs. NOTE: Young signal Transducer Precision conductive plastic potentiometer, conditioning devices clamp the signal to excitation level. Avoid 10K ohm resistance (±20%), 0.25%...
3. ALIGN VANE CALIBRATION FORMULAS a) Connect instrument to an indicator. b) Choose a known wind direction reference point on the Model 05103V-45 Wind Monitor horizon. c) Sighting down instrument centerline, point nose cone at WIND SPEED vs PROPELLER RPM reference point on horizon.
Screw nose cone into main housing until o-ring seal is shaft and tighten set screw*. seated. Be certain threads are properly engaged to avoid g) Place potentiometer coupling on potentiometer cross-threading. adjust thumbwheel. Do Not tighten set screw yet. 05103V-45-90(E) *Max set screw torque 80 oz-in Page 3...
Check bearing condition Liability is limited to repair or replacement of defective item. A copy of the warranty policy may be obtained from R. M. Young Company. using a Model 18331 Vane Torque Gauge. Since this procedure is similar to POTENTIOMETER CE COMPLIANCE REPLACEMENT, only the major steps are listed here.
Page 9
05121E-10-45 JUNCTION BOX COVER - ICEPHOBIC COATED 05129 BAND CLAMP (INCL. W/ 05121E, 05128B) 05128B ORIENTATION RING R. M. YOUNG COMPANY 2801 Aero Park Drive , Traverse City, Michigan 49686 U.S.A. TEL (231) 946-3980 FAX (231) 946-4772 05103V-45-90(E) Page 8...
Calibration Accessories Model 18802 Anemometer Drive Model 18112 Vane Angle Bench Stand Model 18331 Vane Torque Gauge Model 18212 Vane Angle Fixture-Tower Mount Model 18310 Propeller Torque Disc Model 18301 Vane Alignment Rod...