Check the following items before using this product.
Controller Type(Product Name)
Check the model number on the top of the controller.
Bundled Items
Make sure that the following items are in the package.
• Controller × 1 Mounting frame × 1 Sensor head × 1
• Hexagonal nut × 2 (For GP-X10M, GP-X12ML and GP-X22KL only)
• Toothed washer × 1 (For GP-X10M, GP-X12ML and GP-X22KL only)
• Instruction Manual (This publication) × 1
Main Specifications
Sensor head
0 to 0.8mm
Stainless steel (SUS304)/ Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm
-10 to +55
35 to 85% RH, Storage: 35 to 85% RH
Power line: 300Vp 10ms cycle,and 0.5 s pulse width (with noise simulator)
250V AC for one min. between all supply terminals connected together and enclosure
20M ,or more, with 250V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, 0.75mm amplitude, in X, Y and Z directions for two hours each
500m/s
2
acceleration (50G approx.) in X, Y and Z directions for five times each
Stainless steel (SUS303)
ABS
Connector attached high frequency coaxial cable, 3m long (Note 4)
Extension up to 10m is possible with the optional cable
40g approx.
1) Where measurement conditions have not been specified precisely, the conditions used were
an ambient temperature of +20
.
2) The sensing range is specified for the standard sensing object.
3) The value represents 20 to 60% of the maximum sensing distance when combining the sensor
head and controller.
4) For the flexible cable type, please contact our office.
5) The given weight of the threaded type sensor head is value including the weight of the nut and
toothed lock washer.
6) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be
deteriorated due to added substances in the oil. Please check the resistivity of the sensor against
the cutting oil you are using beforehand.
Contoroller
Output voltage:
Output impedance: 100
0.04% F.S. (64 times average)
<NPN output type>
NPN open-collector transistor
Maximum sink current: 100mA
Applied voltage: 30V DC or less
(between output and 0V)
Residual voltage: 1.6V or less
(at 100mA sink current)
0.4V (at 16mA sink current)
<NPN output type>
Photo coupler input
Input current: 9mA or less
Operating voltage: ON voltage 17V or more
(between
OFF voltage 4V or less
(between
Input impedance: 5k
approx.
Push button setting/External input setting
Orange LED (lights up when the upper value is exceeded)
Green LED (lights up when within the upper and lower limit value)
Orange LED (lights up when less than the lower limit value)
Green LED (lights up as per the external or internal trigger timing)
5 digit orange LED (display of numerical values out of the upper and lower limit value)
5 digit green LED (display of numerical values within the upper and lower limit value)
INSTRUCTION MANUAL
0 to 1mm
0 to 2mm
0 to 5mm
0.07%F .S ./
or less
IP67 (IEC) , IP67G (Note6)
, Storage: -20 to +70
Brass (Nickel plated)
PAR
ABS
PP
40g approx.
40g approx.
50g approx.
45g approx.
24V DC 10% Ripple P-P 10% or less
150mA or less
5 to
5V (Note 5)
approx.
0.075ms (Fastest)
0.02% F.S. (64 times average processing)
Within
0.3% F.S.
0.07% / F.S./°C or less
<PNP output type>
PNP open-collector transistor
Maximum source current: 100mA
Applied voltage: 30V DC or less
(between output and
Residual voltage: 1.6V or less
(at 100mA source current)
0.4V (at 16mA source current)
Incorporated
<PNP output type>
Photo coupler input
Input current: 9mA or less
Operating voltage: ON voltage 17V or more
24V and input)
(between 0V and input)
OFF voltage 4V or less
24V and input)
(between 0V and input)
Input impedance: 5k
approx.
40kHz (25 s)
Orange LED (lights up in mode status)
Where measurement conditions have not been specified precisely, the conditions used were an
ambient temperature of +20°C.
2) This value was obtained at a constant +25°C.
3) The value is in the range from 20 to 60% of the maximum detection distance with a combination of
sensor head and controller.
4) When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.
5) Adjusted to a 0 and +5V factory setting.
Precautions
Connection
The GP-X series is configured to satisfy the specification with the combination of the sensor head
and the controller. Use the sensor head and controller in combination without fail; with other
combinations, not only may the specifications may not be satisfied but also failure may result.
Turn the controller off before mounting or removing the sensor head and controller.
Note that the cables will be damaged if they are pulled.
Power Supply
Wait 15 minutes (or 20 minutes with GP-X3S and GP-X5S) after the power is turned on before
operation is started. There may be a variation in the measurements immediately after power-on
because the power circuit is not stable.
There is a muting time of about two seconds after the power is turned on.
Take care that wrong wiring may damage the sensor.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.)
terminal of the power supply is connected to an actual ground.
Make sure to use an isolation transformer for the DC power supply. If an auto-transformer
0 to 10mm
(single winding transformer) is used, this product or the power supply may get damaged.
In case a surge is generated in the used power supply, connect a surge absorber to the supply
and absorb the surge.
Wiring
Do not run the wires together with high-voltage lines or power lines or put them in the same
raceway. This can cause malfunction due to induction.
Make sure that the power supply is off while wiring.
The analog voltage output is incorporated with a short circuit protection circuit. Do not connect
it directly to a power supply or a capacitive load.
Be careful to avoid statically charging connectors during wiring work. A failure may result.
Use the exclusive extension cable for cable extension of the sensor head.(Overall length: 10m)
Environment
PA
This product has been developed / produced for industrial use only.
Avoid dust, dirt, and steam.
Take care that the sensor does not come in direct contact with water, oil, grease, or organic
solvents, such as, thinner, etc.
In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity
80g approx.
of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
Take care that stress is not directly applied to the cable joint.
This sensor is for indoor use only.
Compatibility
In case the sensor head is broken, the sensor head replacement is possible with same model.
(However, entering a characteristics code (ID code) and calibration are required)
Mounting Method
Tighten the sensor head to the torque specified below.
Mounting with set screw
<Column type>
Use an M3, or less, cup-point set screw.
V)
In case the interference prevention
function is not used
If sensor heads are mounted close
together without using the interference
prevention function, reserve the distance
specified below.
Model no. of
sensor head
0 to+50°C (No dew condensation), Storage: 0 to+50°C
35 to 85%RH, Storage: 35 to 85%RH
Power supply line: 1,000Vp, 10ms cycle, 0.5 s pulse width
Radiation: 300Vp, 10ms cycle, 0.5 s pulse width (with noise simulator)
10 to 55Hz frequency, 0.75mm amplitude in X, Y and Z directions for two hours each
2
100m/s
acceleration (10G approx.) in X, Y and Z directions five times each
Floating earth
Enclosure: Polycarbonate
120g approx.
ATA4811 (Controller mounting bracket): 1 set
Mounting with nut
<Screw type>
Distance from surrounding metal
As metal around the sensor may affect the detection,
take care of the following.
<Embedding of the sensor in metal>
Measurement value or analogue voltage output may be
changed if the sensor is completely embedded in metal.
Keep the minimum distance specified in the table below.
(
)
(
)