Cd Test Mode - Pioneer DEH-4200SD/XNEW5 Service Manual

Cd rds receiver
Table of Contents

Advertisement

5

6.2 CD TEST MODE

- Flow Chart
[3] + [DISP] -> Reset
[CD] or [SOURCE]
Test Mode IN
Source ON
TRK
MIN
[BAND]
Power On
(T.Offset is adjusted)
TRK
MIN
00 00 00
[BAND]
[3]
Power Off
Focus Close
S curve check
TRK
MIN
SEC
TRK
MIN
91 91 91
[BAND]
[1]
T.Close & AGC
Power Off
Applicable servomechanism
TRK
MIN
SEC
TRK
MIN
?tr ?min ?sec
[BAND]
[1]
Power Off
F,T,RF AGC
F.Bias display switching
TRK
MIN
SEC
TRK
MIN
??
??
[BAND]
Power Off
TRK
MIN
SEC
t
*1)
TYP
TRK
MIN
SEC
TRK
t
*2) Focus Close
S. Curve
TRK
MIN
SEC
TRK
MIN
00
00
00
01
TRK
MIN
SEC
(
99
99
99)
*3) F.Offset Display t T.Offset Display t Switch to the
*4) 100TR Jump
*7) TRK/MIN/SEC t F.AGC t T.AGC Gain t F.Bias t RF AGC
*8) CRG motor voltage = 2 [V]
t
*9)
TYP (1X)
TRK
MIN
SEC
TRK
22
After the [EJECT] key is pressed keys other than the [EJECT] key should not be pressed, until disc ejection is complete.
When the key [2] or [3] is pressed during the Focus Search, the power supply should be immediately turned off (otherwise the lens sticks
to Wall, causing the actuator to be damaged).
100TR Jump, the mechanism shall be set to the Tracking Close mode when the key is released.
When the power is turned on/off the gain of the RFAMP is reset to 0 dB. At the same time all the self-adjusting values shall return to the
default setting.
Do not do Tracking Servo Close before doing Focus Servo Close. (Because the overcurrent flows)
5
6
[Key]
Contents
Display
[2]
RF AMP
Gain switching
SEC
TRK
MIN
GG
GG
[6]
[1]
Focus Mode switching
Tracking Servo
*2
Close
SEC
TRK
MIN
SEC
00 00 00
0X
0X
0X
or 99 99 99
[3]
RF AGC /
RF AGC coefficient display
SEC
TRK
MIN
??
??
[3]
*7
F,T AGC / F.Bias
RF AGC
SEC
TRK
MIN
SEC
??
?tr ?min ?sec
t
+ 6 dB
+ 12 dB
MIN
SEC
TRK
MIN
SEC
06
06
06
12
12
12
t
F EQ measurement setting
SEC
TRK
MIN
SEC
01
01
02
02
order of the original display
t
2X
1X
MIN
SEC
TRK
MIN
SEC
22
22
11
11
11
DEH-4200SD/XNEW5
6
7
NOTE
When a CD-DA (regular music CD) is played in the CD test mode, its sound quality
will be temporarily deteriorated. The CD will then repeat normal, deteriorated,
normal... playback.
This is due to the difference in the playback modes between the normal operation
mode and the CD test mode, and the interval of generating deteriorated mode and
the time taken to return to the normal mode depend on the error of each clock.
The time taken to turn to the deteriorated mode is at a minimum around 20
seconds while the time to return to the normal mode is maximum 40 seconds
approximately.
*1
Make sure to check the sound quality in the normal operation mode.
SEC
GG
[<]
[>]
CRG +
CRG -
*8
00 00 00
00 00 00
or 99 99 99
or 99 99 99
[<]
[>]
CRG +
CRG -
SEC
8X 8X 8X
8X 8X 8X
??
or 9X 9X 9X
or 9X 9X 9X
[<]
[>]
CRG/TR Jump +
CRG/TR Jump -
*4
TRK
MIN
SEC
TRK
MIN
?tr ?min ?sec
?tr ?min ?sec
[2]
Tracking Open
8X 8X 8X
or 9X 9X 9X
[Key]
[BAND]
Power On/Off
CRG + / TR Jump +
[<]
(Direction of the external surface)
CRG - / TR Jump -
[>]
02
(Direction of the internal surface)
[1]
T. CLS & AGC & Applicable servomechanism /
AGC,AGC display setting
[2]
RF Gain switching / Offset adjustment display /
T.Balance adjustment / T. Open
[3]
F. Close,S. Curve / Rough Servo and RF AGC /
F,T,RF AGC
[6]
F. Mode switching / Tracking Close
t
*10)
OFF(TYP)
TRK
MIN
SEC
7
8
[2]
Self-adjusting
*8
switching
*3
TRK
MIN
SEC
??
??
??
[2]
T.Balance adjustment /
T.BAL coefficient display
TRK
MIN
SEC
??
??
??
[2]
Tracking Open
*4
SEC
8X 8X 8X
or 9X 9X 9X
*6
Operation
Test Mode
t
FORCUS
TRACKING
TRK
MIN
SEC
TRK
MIN
SEC
70
70
70
71
71
8
A
B
C
D
E
71
F
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Deh-3200ub/xnew5

Table of Contents