Pioneer PRO-110FD Service Manual page 178

Plasma display system
Hide thumbs Also See for PRO-110FD:
Table of Contents

Advertisement

1
A
Recovery flowchart (2-3)...Changing the VOL YNOFS3/4/1 setting voltage
[From the Main flowchart (2)]
RST MASK 22 (Cyan 3SF)
Set VOL YNOFS1 to the tentative setting value. / [VY1 ***]
Set VOL YNOFS3 to the current setting value minus 4. / [VY3 ***]
B
Set VOL YNOFS4 to the current setting value minus 4. / [VY4 ***]
Current VOL YNOFS3 setting value < 094?
Is there erroneous discharge (abnormal lit cell)?
C
Display RST MASK 16 (Green 1023+). / [MKS S66]
Set VOL YNOFS3 to the current setting value minus 47. / [VY3 ***]
Set VOL YNOFS4 to the current setting value minus 47. / [VY4 ***]
Is there erroneous discharge (abnormal dead cell)?
D
(Check on the PANEL 1-ADJ menu.)
Display RST MASK 15 (Red 1023+). / [MKS S65]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
E
Set VOL YNOFS3 to the current setting value plus 23. / [VY3 ***]
Set VOL YNOFS4 to the current setting value plus 23. / [VY4 ***]
Determine the current setting value for VOL YNOFS3 as the final value.
Determine the current setting value for VOL YNOFS4 as the final value.
Set VOL YNOFS1 to the final setting value of VOL YNOFS3 minus 31.
Determine the current VOL YNOFS1 setting value as the final value.
F
[To the Main flowchart (2)]
138
1
2
No
No
No
No
/ [VY1 ***]
2
3
Replacement of abnormal circuits or
Yes
re-replacement of the panel required
Yes
Yes
Replacement of abnormal circuits or
re-replacement of the panel required
Yes
Replacement of abnormal circuits or
re-replacement of the panel required
PDP-5010FD
3
4
VOL YNOFS3 final setting value
Note:
Make a note of this VOL YNOFS3 value.
4