INSTALLATION PRECAUTIONS
1. DRAIN PIPE INSTALLATION
(REVERSE CYCLE MODEL)
Since drain water flows from the outdoor unit during
heating and cooling operation, when it is installed at a
high place, install the drain pipe as shown in Fig. 1 and
connect it to a 16mm (inside diameter) hose available
anywhere. When installing the drain pipe, fill the holes
indicated by the
mark other than the hole for the
drain pipe in the bottom of the outdoor unit with a drain
cap to prevent water leakage. (Fig. 2 and 3)
Fig.1
Drain pipe hole
Fig. 2
Drain pipe (2)
Drain cap (2)
Fig. 3
Air frow
Bottom
31-21/32" (804mm)
Drain pipe mounting hole
Fig. 4
Drain pipe
Drain hose
(commercial hose, inside
diameter 16mm)
NOTE :
Installation in cold regions. Do not use the accessory drain
pipe. (If the drain pipe is used, the drain water in the pipe may
freeze in extremely cold weather.)
Bottom plate
Drain pipe
Bottom
Drain cap
3/4" (19mm)
Hole
Drain cap
2. FORMING THE DRAIN HOSE AND PIPE
[Rear piping, Right piping, Bottom piping]
• Install the indoor unit piping in the direction of the wall
hole and bind the drain hose and pipe together with
vinyl tape. (Fig. 5)
• Install the piping so that the drain hose is at the
bottom.
• Wrap the pipes of the indoor unit that are visible from
the outside with decorative tape.
Fig. 5
Cut off the piping
outlet cutting
groove with a
hacksaw, etc.
Decorative
tape
Right piping
Notch the thin part
of under cover A.
Indoor unit drain hose
[For Left rear piping, Left piping]
Interchange the drain cap and the drain hose.
• For left piping and left rear piping, align the marks on
the wall hook bracket and shape the connection pipe.
• After passing the indoor piping and drain hose
through the wall hole, hang the indoor unit on the
hooks at the top and bottom of the wall hook bracket..
Fig. 6
Connection pipe
1/4" (6.35 mm) dia.
Connection pipe
3/8" (9.52 mm) dia.
– 19 –
Pipe (top)
Rear piping
Bind with
vinyl tape
Indoor unit drain
Bottom piping
hose (bottom)
For left outlet piping,
cut off the piping
outlet cutting groove
with a hacksaw.
Drain cap
Remove the drain cap by
pulling at the projection at the
end of the cap with pliers, etc.
Align the marks.