Table of Contents

Advertisement

Quick Links

AquaLink
Control Systems
For use with
AquaLink RS Systems
with Rev O.2 - T.1 Firmware
FOR YOUR SAFETY - This product must be installed and serviced by a contractor
who is licensed and qualified in pool equipment by the jurisdiction in which the
product will be installed, where such state or local requirements exist. In the event
no such state or local requirement exists, the maintainer must be a professional with
sufficient experience in pool equipment installation and maintenance, so that all of
the instructions in this manual can be followed exactly. Before installing this product,
read and follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property damage,
personal injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which
can cause serious injury, property damage, or death.
®
RS OneTouch
WARNING
OWNER'S MANUAL
ENGLISH

Advertisement

Table of Contents
loading

Summary of Contents for Jandy Pro Series AquaLink RS OneTouch Control Systems

  • Page 1 OWNER’S MANUAL ENGLISH ® AquaLink RS OneTouch ™ Control Systems For use with AquaLink RS Systems with Rev O.2 - T.1 Firmware WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed, where such state or local requirements exist.
  • Page 2 Page 2 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ®...
  • Page 3: Table Of Contents

    Page 3 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® TABLE OF CONTENTS Section 1. Important Safety 4.3.3.(A) Variable Speed Pump Instructions....5 (Setup) ....... 21 4.3.3.(B) Pump Model ...... 21 Section 2. Display ......8 4.3.3.(C) Pump Application....21 4.3.3.(D) Min-Max Settings ....
  • Page 4 Page 4 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.6.5.(D) Completing/Continuing 5.2.2 Auto Switching ....... 43 Sprinkler Programming..36 OneTouch ........44 Controls .......... 36 5.3.1 OneTouch Setup ....44 4.7.1 RS Interlink (Pwr Ctr B) ..36 Section 6. Glossaries ......
  • Page 5: Important Safety Instructions

    Page 5 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® SECTION 1. IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: WARNING...
  • Page 6 Page 6 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® WARNING To Reduce the Risk of Injury - • The water in a spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F (40°C) are con- sidered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes.
  • Page 7 Page 7 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® WARNING A terminal bar marked “GROUND” is provided within the power center. To reduce the risk of electrical shock, connect this terminal bar to the grounding terminal of your electric service or supply panel with a continuous copper conductor having green insulation and one that is equivalent in size to the circuit conductors supplying this equipment, but no smaller than no.
  • Page 8: Display

    Page 8 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® SECTION 2. DISPLAY 2.1 USER INTERFACE (UI) The AquaLink RS One Touch automated programs. The function operates pool/spa equipment of the various navigation buttons are through main system menus and/or outlined below.
  • Page 9: Air Temperature Display

    HELP SPA MODE PROGRAM Page 9 ENGLISH SET TEMP AquaLink RS OneTouch™ | Owner’s Manual ® SET TIME CLEAN MODE OFF DISPLAY LIGHT LOCKOUTS 2.3 AIR TEMPERATURE DISPLAY PROGRAM GROUP SYSTEM SETUP ALL OFF System Setup NEXT Air Temp MENU/HELP SYSTEM SETUP Display SYSTEM...
  • Page 10: Help

    Page 10 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 3.3 HELP Menu JANDY AquaLink RS MENU/HELP Help 01/31/03 Mon Program The HELP menu provides access Set Time 6:00 PM to the KEYS, SERVICE and Set Temp DIAGNOSTICS sub menus. Display Light Filter Pump OFF Lockouts...
  • Page 11: Diagnostics

    Page 11 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 3.3.3 DIAGNOSTICS HELP Model 6529 Choose a topic Type RS-8 Combo with arrow keys Firmware MENU/HELP HELP and press select Select to find the status of system Go Back Sensors connections, and check those Water Keys...
  • Page 12: Dusk Setup

    Page 12 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 3.4.3 DUSK SETUP System Setup Dusk Setup MENU/HELP In Floor Clean SYSTEM SETUP Sunset At 7:30 Solar Priority Pump Lockout Select to set up equipment to Dusk Ctrl Assign JVAs Off At 12:00 AM automatically activate at sunset.
  • Page 13: System Temperature

    Page 13 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® Seasonal Adjust Values Program Default Adjustable Range Filtration 1 hr .5 hr 1.5 hrs, 2 hrs Cleaner 1 hr .5 hr 1.5 hrs, 2 hrs Filter Pump † AquaPure 10%, 15%, 20% ®...
  • Page 14: Maintain Temp

    Page 14 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 3.5.3 MAINTAIN TEMP System Setup Maintain Temp Setup MENU/HELP Spa Link SYSTEM SETUP Dusk Setup Measure Water All Off Time Select to set how often the water Temperature Product Info Every: 2 Hrs.
  • Page 15: Security

    Page 15 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® CAUTION Activating the spa during freezing conditions will override freeze protection. This means that if you are using your spa when freezing conditions exist, freeze protection will not circulate water to non-spa related equipment that you may have freeze protected (e.g.
  • Page 16: B) Password Protect Devices

    Page 16 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® • If you forget your password Enter Menu please contact you local or Password Help preferred dealer. 1 2 3 4 Program Set Temp • When a password restriction is set Set Time the feature will display “ENA”.
  • Page 17: Clear Memory

    Page 17 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 3.6.3 CLEAR MEMORY Clear Memory System Setup Warning Solar Priority MENU/HELP SYSTEM SETUP Assign Jvas Dimmers Clearing Memory The Clear Memory setup menu is Color Wheels Erases All Spa Switch used to clear all stored values from Stored Settings Spa Link...
  • Page 18: All Off Time

    Page 18 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.1.1 ALL OFF TIME All Off Time All Off Time MENU/HELP SYSTEM SETUP Feature Feature Off Time 11PM Off Time Select to set an automatic time each day for the system to enter the ALL RROWKEYS Highlightan OFF mode.
  • Page 19: Program Filter Pump

    Page 19 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.3.1.(B) PROGRAM FILTER PUMP Program Filter Pump MENU/HELP PROGRAM VSP1 SPD PGM Select to program the ON and OFF times for the filter pump or to Aux 2 More change, add or delete existing filter pump programs.
  • Page 20: Spa

    Page 20 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.3.2 SPA Filter Pump Spa Will 4.3.2.(A) ON/OFF Pool Heat Turn On Spa Heat After Delay EQUIPMENT ON/OFF Solar Heat Aux 1 Select to switch water circulation Aux 2 Aux 3 from the pool to spa (pool/spa “PS”...
  • Page 21: Variable Speed Pump

    Page 21 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.3.3 VARIABLE SPEED PUMP 4.3.3.(A) VARIABLE SPEED PUMP (SETUP) MENU/HELP SYSTEM SETUP Select to set up the variable speed application, speed and speed/flow pump. The following functions limits, custom labels as well as provide controls for selecting the priming speed and duration.
  • Page 22: Min-Max Settings

    Page 22 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.3.3.(D) MIN-MAX SETTINGS MENU/HELP SYSTEM SETUP VAR SPEED PUMP MIN-MAX SETTINGS Select to set a minimum and Min-max Settings Pump Application maximum global speed or flow. Pump 1 Pump 1 Scale •...
  • Page 23: E-2) Label Speeds

    Page 23 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® Default Speed Labels Speed/labels Label Speeds Pump 1 for Dual Equipment Pump 1 Default Pool Pump Spa Pump Set Speed Pump 2 Label Speeds Pump 3 POOL SPEED 1 Assign Speeds Pump 4 SPEED 2 SPEED 3...
  • Page 24: F) Prime

    Page 24 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.3.3.(F) PRIME MENU/HELP SYSTEM SETUP VAR SPEED PUMP PRIME Set Prime Speed Prime Settings Select to set and maintain the speed (RPM) Pump 1 and duration of the priming of the 2500 pump.
  • Page 25: Auxiliary Equipment (Aux)

    Page 25 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.3.5 AUXILIARY EQUIPMENT (AUX) Filter Pump Filter Pump EQUIPMENT ON/OFF Pool Heat Pool Heat Select to toggle auxiliary Spa Heat Spa Heat Solar Heat Solar Heat equipment on and off. Aux 1 Aux 1 •...
  • Page 26: Heating And Cooling

    Page 26 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.4 HEATING AND COOLING 4.4.1 POOL HEAT AND SPA HEAT Filter Pump EQUIPMENT ON/OFF Pool Heat Select POOL HEAT to enable the Spa Heat Pool Heat heater for the pool or SPA HEAT to Enabled enable the heater for the spa.
  • Page 27: Solar Heat

    Page 27 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.4.3 SOLAR HEAT Filter Pump Filter Pump EQUIPMENT ON/OFF Pool Heat Pool Heat Spa Heat Spa Heat Solar Heat Solar Heat Select to enable or turn off the Aux 1 Aux 1 solar heat equipment.
  • Page 28: Heat Pump

    Page 28 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.4.5 HEAT PUMP Filter Pump Filter Pump EQUIPMENT ON/OFF Pool Heat Pool Heat Spa Heat Spa Heat HEAT PUMP will display instead Heat Pump Heat Pump of SOLAR HEAT/EXTRA AUX Aux 1 Aux 1 when installed correctly.
  • Page 29: A) Chiller - Rs485

    Page 29 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.4.6.(A) CHILLER - RS485 Filter Pump Filter Pump • Set the DIP Switch S2-1 to OFF Pool Heat Pool Heat and connect the solar sensor to the Spa Heat Spa Heat Solar Heat Solar Heat solar sensor input to operate the...
  • Page 30: Temp 1 & Temp 2 (Pool Or Spa Only)

    Page 30 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.4.8 TEMP 1 & TEMP 2 (POOL OR SPA ONLY) Filter Pump EQUIPMENT ON/OFF Temp 1 Temp 2 Temp 1 Select TEMP 1 to set the system’s Solar Heat priority temperature. must be set higher than Filter Pump...
  • Page 31: Set Color Lights

    Page 31 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.5.2 SET COLOR LIGHTS System Setup Light Setup MENU/HELP Air Temp SYSTEM SETUP Warning Dimmers Can Not Temp Calibrate Select to choose a product and Be Assigned To In Floor Clean assign it to an auxiliary relay.
  • Page 32: Set Laminar Pulse

    Page 32 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.5.4 SET LAMINAR PULSE Label Aux2 Label Aux Aux1 Current Label MENU/HELP SYSTEM SETUP LABEL AUX Aux2 Aux2 Aux3 General Labels Select to assign a Laminar Light Aux4 Light Labels to an auxiliary relay.
  • Page 33: Cancel Today

    Page 33 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® • Access program or manual control • There are three (3) Sprinkler via SPRINKLERS menu in the system states: EQUIPMENT ON/OFF menu. OFF: • Sprinklers are disabled until • SPRINKLERS will not appear in it is re-enabled.
  • Page 34: Enable Programs

    Page 34 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.6.3 ENABLE PROGRAMS Aux5 Sprinklers Aux5 Cancel Today Aux5 EQUIPMENT ON/OFF SPRINKLERS Manual Start Extra Aux Enable Programs Sprinklers Sprinkler programs must be Disable Programs Spa Mode enabled for programs to run automatically at their start time.
  • Page 35: Set Program Start Time

    Page 35 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.6.5.(A) SET PROGRAM START TIME Sprinkler Setup MENU/HELP SYSTEM SETUP SPRINKLERS Program 2: ON Sprinkler Setup Select to set the time for a specified Program 2: ON START: 8:00AM START: 8:00AM START: 8:00AM Start: 8:00AM sprinkler program to begin.
  • Page 36: Controls

    Page 36 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® • Valve durations are adjustable from • If the end time of an enabled OFF to 240 minutes, in increments program overlaps with the start of 1 minute to 240 minutes, or in time of a second enabled program, increments of 10 minutes from 10 the second program delays until...
  • Page 37: A) Rs Interlink

    Page 37 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.7.1.(A) RS INTERLINK SETUP ® MENU/HELP SYSTEM SETUP Select to set up single controller • Any custom name provided will appear on the Main System Menu access for two (2) power centers on screen.
  • Page 38: Spalink

    Page 38 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.7.3 SPALINK ® System Setup Spa Link Setup Solar Priority Assign JVAs MENU/HELP Please select SYSTEM SETUP Dimmers the number of Spa Switch Select to set the equipment SPA LINKS Spa Link you have.
  • Page 39: Cover-Pools

    Page 39 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.7.4 COVER-POOLS ® MENU/HELP SYSTEM SETUP Cover-pools Disable Devices Setup When Cover Cover Closed Select to set the options for your Is Closed Aux1 Cover-Pools equipment. Aux2 Aux3 • Though the Cover-Pools Disable Devices Aux4 AquaPure Adjust...
  • Page 40: Jandy

    Page 40 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.8 JANDY VALVE ACTUATORS ® 4.8.1 ASSIGN JVA System Setup Assign Jvas Solar Priority MENU/HELP SYSTEM SETUP Assign JVAs Intake Used Dimmers Select to assign Jandy Valve Return Used Color Wheels Cleaner Free Actuators (JVAs) to any auxiliary...
  • Page 41: Aquapure

    Page 41 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.9 AQUAPURE ® 4.9.1 SET AQUAPURE Set Aquapure MENU/HELP Menu Set Pool To: 0% Menu Set Spa To: 0% Select to set chlorine output Program Set Temp percentage from the AquaPure Set Time Highlight an chlorine generation system to both...
  • Page 42: Set Up Automatic On & Off Times

    Page 42 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 4.9.2.(A) BOOST POOL SETUP MENU/HELP System Setup SYSTEM SETUP Boost Pool OneTouch Setup Select to adjust the number of Label Aux Aquapure Time hours or mode of the Boost Pool. Freeze Protect Mode Pool...
  • Page 43: Program Groups

    Page 43 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 5.2 PROGRAM GROUPS MENU/HELP MENU Program Group Help Select or create specific settings Program that will change seasonally or when Group A Set Temp Group B Set Time the user is away. Auto Pgrm Group Display Light Lockouts...
  • Page 44: Onetouch

    Page 44 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 5.3 ONETOUCH ONETOUCH ON/OFF Spa Mode OneTouch4 Select to access up to six (6) mood/ scene settings that will run multiple devices and heat to preset water Clean Mode OneTouch5 temperatures with a single button.
  • Page 45: Glossaries

    Page 45 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® SECTION 6. GLOSSARIES 6.1 SAFETY DELAYS AND LOCKOUTS Cleaner Lockout The pool cleaner will only activate if the system is in pool mode (i.e., water circulating to pool). The pool cleaner requires that water is circulating to the pool in order for it to operate.
  • Page 46: Special Auxiliary Labels

    Page 46 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® 6.2 SPECIAL AUXILIARY LABELS Air Blower When an AUX button labeled “Air Blower” is pressed, it will turn on the air blower for 30 minutes, then automatically turn it off. An air blower may be programmed like any other auxiliary, except that you can program only the ON time.
  • Page 47 Page 47 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® PUMP WILL TURN OFF AFTER COOL DOWN CYCLE This message indicates that the filter pump is circulating water to cool down the heater. The filter pump will continue to run for five minutes to protect the heater from damage, whenever the heater has fired and has been off for less than five (5) minutes.
  • Page 48: Onetouch Menu Tree

    Page 48 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® SECTION 7. ONETOUCH MENU TREE MENU/HELP EQUIPMENT ON/OFF ONETOUCH ON/OFF HELP SPRINKLERS SPA MODE KEYS CANCEL TODAY CLEAN MODE SERVICE MANUAL START ENABLE PROGRAM DIAGNOSTICS ALL OFF DISABLE PROGRAM MODEL ONTOUCH 4 *EQUIPMENT SENSORS...
  • Page 49 Page 49 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® DAYLIGHT SAVINGS PRODUCT INFO ENABLED CLEAR MEMORY DISABLED TEMP CALIBRATE HEAT PUMP SET TEMP HEAT MODE CHILL MODE IN FLOOR CLEAN HEAT PUMP W/RS485 SOLAR HEAT PRIORITY ENABLED LOW TEMP DISABLED HEAT PUMP PRIORITY DEVICE RUNTIME...
  • Page 50 Page 50 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® NOTES...
  • Page 51 Page 51 ENGLISH AquaLink RS OneTouch™ | Owner’s Manual ® NOTES...
  • Page 52 EQUIPMENT INFORMATION RECORD DATE OF INSTALLATION _________________________________________ INSTALLER INFORMATION _______________________________________ INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER) ___________________________________________ PUMP MODEL __________________ HORSEPOWER ______________ FILTER MODEL _________________ CONTROL PANEL MODELSERIAL NUMBER _________________________ NOTES: _______________________________________________________ _______________________________________________________________ _______________________________________________________________ Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 | www.ZodiacPoolSystems.com Zodiac Pool Systems Canada, Inc.

Table of Contents