Description
No light output.
No power at luminaire.
DMX Data Control.
Local programming.
3 4
TROUBLESHOOTING
Symptom
Unit is set to Preset Off...
Make sure unit is set to proper Preset.
DMX command to 0 intensity...
Fixture will not produce or
Adjust intensity to higher level.
output light
Luminaire has detected an over temperature condition (thermal
overload)...
When thermal condition is resolved, recycle power.
Circuit not energized...
verify circuit breaker is turned on.
Not plugged in...
Luminaire does not power up
ensure A/C cable is connected to power source.
Power cable wired incorrectly...
verify power cable and connector are wired correctly.
See
Not detecting DMX data...
Disconnect and reconnect DMX input cable.
Unit is not set to be controlled by DMX - check menu settings.
Fixture will not respond to DMX
Check all DMX connections (at control source and luminaire).
commands.
DMX data cable not wired correctly or has a broken conductor...
check DMX data cable for proper wiring.
See
information.
Password protection is on (locked)...
Input proper password to allow local programming and/or
Unit will not allow local
adjustments.
programming or changes.
Unit is controlled by DMX...
Disconnect input cables to check issue.
PL House Light MKII LED Luminaires
Possible Cause/Remedy
"Connecting Power" on page 7