Event condition Tab

Create event execute conditions for each action.
Event condition 1, 2, 3, 4, 5
Select the event condition.
You can combine the alarm using the following event
execute conditions.
and: detect when both conditions happen within a
specified interval regardless of the sequence.
or: detect when either condition happens.
then: detect when each of the conditions happen within
a specified interval in sequence.
If you set the event condition to None, the following
alarm 1, 2, 3 menus appear.
1, 2, 3
Select the alarm.
Selectable alarms are as follows.
Displayed items vary depending on the function.
Sensor input 1: The external sensor that is connected to
sensor input 1 of the camera I/O port.
Sensor input 2: The external sensor that is connected to
sensor input 2 of the camera I/O port.
Presence sensor: The alarm is triggered by the presence
sensor function.
Camera tampering detection: The alarm is triggered if
the camera detects tampering, such as direction
shifting or spray.
Motion detection: The alarm is triggered by the motion
detection function.
VMF: The alarm is triggered by the VMF function.
Face detection: The alarm is triggered by the face
detection function.
Network disconnection: The alarm is triggered by
disconnection to a specific IP address.
56
Setting the Sensor input/Camera tampering detection/Motion detection — Action input Menu
Note
You cannot set more than two functions for Presence
sensor, Camera tampering detection or Network
disconnection in the same event condition.
Interval
Specify the interval time used when condition is set to
and, then.
In the case the condition is set as 1 and 2, the system
sounds an alarm when either 1 or 2 happens, and the
other happens within the specified interval.
In the case the condition is set as 1 then 2, the system
sounds an alarm when 1 happens, and then 2 happens
within the specified interval.
If you select "or" condition, this setting will be ignored.
The maximum duration to be set is 7200 seconds.
Sensor input Tab — Set the sensor
input 1/2
Sensor input mode
Set the direction of the detected input signal to the
sensor input terminal of the camera.
Normally open: Triggers an alarm when the sensor
input is short-circuited.
Normally closed: Triggers an alarm when the sensor
input is open-circuited.
Notes
• Allow at least two seconds for the input signal to be
detected; otherwise, some events may not be detected.
• When you use video streaming by SSL connection, set
as follows. Some events may not be detected if the
camera is not in the following conditions.
– Set the Bit rate below 1 Mbps.
– Set the Frame rate below 30 fps.
– Use the video streaming below two transmissions at
the same time.