Get-Function table
Get Function Length ID
Get-Contrast
8
Get-
8
Brightness
Get-
8
Sharpness
Get-Color
8
Get-Tint
8
Get-Volume
8
Get-Mute
8
Get-Input
8
select
Get-Power
8
status:
ON/ STBY
Get-Remote
8
control
Get-Power
8
lock
Get-Button
8
lock
Get-Menu
8
lock
Get-Setup
8
wizard
Get-PIP
8
mode
Get-PIP input
8
Get-Tiling
8
Mode
Get-Tiling
8
Compensa-
tion
Get-Tiling H
8
by V monitors
Get-Tiling
8
position
Get-ACK
8
Command
Command
Type
(ASCII)
Code (ASCII) Code (Hex) (Three ASCII bytes)
g
a
g
b
g
c
g
d
g
e
g
f
g
g
g
j
g
l
g
n
g
o
g
p
g
q
g
s
g
t
g
u
g
v
g
w
g
x
g
y
g
z
51
Response Range
61
000 ~ 100
62
000 ~ 100
63
000 ~ 100
64
000 ~ 100
65
000 ~ 100
66
000 ~ 100
67
000: Off
001: On (muted)
6A
000~
6C
001: ON
000: STBY
6E
000: Disable
001: Enable
002: Pass through
6F
000: Unlock
001: Lock
70
000: Unlock
001: Lock
71
000: Unlock
001: Lock
73
000: Disable
001: Enable
74
000: OFF
001: PIP
002: PBP
75
000 ~
76
000: OFF
001: ON
77
000: OFF
001: ON
78
01x~09x:
H monitors
0x1~0x9:
V monitors
79
000: OFF
001~025
7A
000
Comments
See Set-function
table
Exclude VT2405-1,
and VT3205
Gets RCU mode
status
(for TV)
(for DS)
(for DS)
See Set-function
table
(for DS)
(for DS)
Bezel width
compensation
(for DS)
1. 2
nd
digital for
H monitors
2. 3
rd
digital for
V monitors
(for DS)
Copy the screen of
Position# to identified
display
This command is
used to test the
communication link