Mitsubishi Electric 800 Series Instruction Manual page 280

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

*1
Indication with a minus sign is not possible via RS-485 or MODBUS RTU communication.
*2
When using the monitor item as the main monitor data on the LCD operation panel (FR-LU08) or the parameter unit (FR-PU07), use Pr.774 to
Pr.776 or the monitor function of the FR-LU08 or the FR-PU07 for setting.
*3
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0.
*4
The actual operation time does not increase if the cumulative running time before power OFF is less than an hour.
*5
When using the parameter unit (FR-PU07), "kW" is displayed.
*6
Differs according to capacities. (FR-F860-00680 or lower/FR-F860-01080 or higher)
*7
The setting is available only for standard models.
*8
When the output current is less than the specified current level (5% of the inverter rated current), the output current is monitored as 0 A. Therefore,
the monitored value of an output current and output power may be displayed as "0" when using a much smaller-capacity motor compared to the
inverter or in other instances that cause the output current to fall below the specified value.
*9
Available when the plug-in option is connected.
*10 Input terminal monitor details ("1" denotes terminal ON, "0" denotes terminal OFF, and "―" denotes undetermined value.)
b15
-
-
-
-
*11 Output terminal monitor details ("1" denotes terminal ON, "0" denotes terminal OFF, and "―" denotes undetermined value.)
b15
-
-
-
-
*12 Option input terminal monitor 1 details (FR-A8AX input terminal status, "1" denotes terminal ON and "0" denotes terminal OFF.) ―― All are OFF
when the option is not connected.
b15
X15
X14
X13
X12
*13 Option input terminal monitor 2 details (FR-A8AX input terminal status. "1" denotes terminal ON, "0" denotes terminal OFF, "―" denotes
undetermined value.) ―― All are OFF when the option is not connected.
b15
-
-
-
-
*14 Option output terminal monitor details (FR-A8AY/A8AR output terminal status. "1" denotes terminal ON, "0" denotes terminal OFF, and "―"
denotes undetermined value.)―― All are OFF when the option is not connected.
b15
-
-
-
-
*15 The increment is 1 when Pr.37 = "1 to 9998" or when Pr.144 = "2 to 12, or 102 to 112". (Refer to
*16 The monitored values are retained even if an inverter fault occurs. Resetting will clear the retained values.
*17 Parameter setting is not available for setting the monitor item as the main monitor data on the LCD operation panel (FR-LU08) or the parameter
unit (FR-PU07). Use the monitor function of the FR-LU08 or the FR-PU07 for setting.
*18 Setting of Pr.1018 Monitor with sign selection is required. Also, it will be displayed without a minus sign on the operation panel. Confirm the
rotation direction with the [FWD] or [REV] indicator.
STP
CS
RES
MRS
(STOP)
-
-
-
-
X11
X10
X9
X8
-
-
-
-
-
-
RA3
RA2
JOG
RH
RM
RL
-
ABC2
ABC1
FU
X7
X6
X5
X4
-
-
-
-
RA1
Y6
Y5
Y4
page
272.)
5.8 (M) Monitor display and monitor output signal
b0
RT
AU
STR
STF
b0
OL
IPF
SU
RUN
b0
X3
X2
X1
X0
b0
-
-
-
DY
b0
Y3
Y2
Y1
Y0
279
5. PARAMETERS
3
4
5
5
5
6
7
8
9
10