Advertisement

Quick Links

An Employee-Owned Company
EF/XF SERIES
WATER SOFTENERS
OWNER'S MANUAL
Water Control Corporation
7150 143rd Ave NW • Ramsey, MN 55303
1-866-405-1268 • www.watercontrolinc.com
WC-OM-EFXF-FRONTPG © Water Control Corporation 1122

Advertisement

Table of Contents
loading

Summary of Contents for WCC EF Series

  • Page 1 An Employee-Owned Company EF/XF SERIES WATER SOFTENERS OWNER’S MANUAL Water Control Corporation 7150 143rd Ave NW • Ramsey, MN 55303 1-866-405-1268 • www.watercontrolinc.com WC-OM-EFXF-FRONTPG © Water Control Corporation 1122...
  • Page 2: Table Of Contents

    An Employee-Owned Company TABLE OF CONTENTS WARNINGS ..............3 BASIC PRINCIPLES ............4 SOFTENING OPERATION ..........5 SPECIFICATIONS ............. 6 DIMENSIONS ..............8 SET-UP PROCEDURES ............. 9 INSTALLATION PROCEDURES .......... 10 INSTALLATION DIAGRAMS ..........11 WIRING DIAGRAMS ............12 PROGRAMMING INSTRUCTIONS ........14 START-UP PROCEDURES ..........
  • Page 3: Warnings

    PRESSURE OUTSIDE THE RECOMENDED PARAMETERS (34-110°F / 20-125 PSI). SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL PLUMBING CODES AND REGULATIONS. CONTACT WCC (WATER CONTROL CORPERATION) FOR MORE INFORMATION. READ THE ENTIRE MANUAL BEFORE INSTALLING, OPERATING, OR MAINTAINING THIS EQUIPMENT.
  • Page 4: Basic Principles

    This ensures fresh brine for each new regeneration. By utilizing Brine Reclamation, a facility will normally see a salt usage reduction of around 25%-35%, without any negative effects on softener capacity, efficiency, or lifespan. For more information on commercial water softening systems, please visit WCC’s website at: watercontrolinc.com or call us at 763-427-9638.
  • Page 5 An Employee-Owned Company SOFTENER OPERATION As water enters the softener, it passes over a resin bed in a special tank. The resin consists of tiny beads of a plastic called styrene. These beads attract and hold sodium ions and exchange the sodium for hardness ions when encountered. Over time, the resin becomes saturated with hardness ions and no longer removes hardness materials.
  • Page 6: Specifications

    An Employee-Owned Company EF/XF SERIES WATER SOFTENERS WCC's "EF" and "XF" Series softeners feature 1¼" water-ways with 1” and 1¼" service connections respectively, light duty electronic control valves, high-strength fiberglass-reinforced mineral tanks, and long-lasting synthetic cation resin. This series is perfectly designed for retail spaces, restaurants, clinics, and office complexes.
  • Page 7 ® ® For a detailed, model-specific specification, please contact WCC (Water Control Corporation). Detailed drawings also available upon request (CAD or Revit Water softening system requires a minimum inlet water pressure of 30 psig and maximum of 120 psig. If resin tank is subject to vacuum, an adequate vacuum relief valve must be properly installed.
  • Page 8: Dimensions

    All dimensions are approximate and subject to change without notice. Please consult our technical department for additional system information. CONTACT YOUR LOCAL SPEAK DIRECTLY WITH ONE OF VISIT US ONLINE SALES REPRESENTATIVE WCC’S DESIGN ENGINEERS To find your authorized WCC representative, Go to www.watercontrolinc.com, where Call 1-866-405-1268 or email please visit: www.watercontrolinc.com/ you’ll find detailed product specification techsupport@watercontrolinc.com.
  • Page 9: Installation Procedures

    CONNECT WATER PIPING. See install diagrams for plumbing layout. Important: Make all sweat-solder connections within 6 inches of softener before applying threaded fittings. Overheating may cause damage to valve. Note: WCC recommends installing isolation valves on the inlet and outlet of each control valve, as well as a full system bypass.
  • Page 10: Installation Diagrams

    An Employee-Owned Company SIMPLEX INSTALLATION DIAGRAM Commercial Softener Simplex Date 07/21/2021 Installation Diagram Drawn by Water Control Corporation 7150 143rd Ave NW • Ramsey, MN 55303 Phone: 763-427-9638 • Fax: 763-427-5665 www.watercontrolinc.com ©Water Control Corporation 1121...
  • Page 11 CK10EE, WS1EE & WS125EE Meter Softener Programming Setting Time of Day Push NEXT until time of day screen is displayed. Press and hold until SET TIME is dis- played and the hour flashes once. Press until the correct hour is displayed. Then press NEXT.
  • Page 12 EE Man u al Page 5 Regeneration and Error Screens Regen Screen Displays the time remaining in the current cycle. Pressing REGEN advances to the next cycle. Error Screen Alternated fl ashing Err and error code every 3 seconds. Clear by disconnecting the power supply at the PC board and reconnecting, or press NEXT and REGEN simultaneously for 3 seconds.
  • Page 13 Page 6 EE Man u al User Displays When the system is operating, one of fi ve displays may be shown. Pressing NEXT will General Operation alternate between the displays shown below. User 1 Typical user display. Shows volume remaining to regeneration. This screen will not be viewed if the control is set for time-clock operation.
  • Page 14: Startup Procedures

    Bypass installed? Yes ☐ No ☐ Master Bypass ☐ Each Valve ☐ ☐ Water test kit provided to end user (only if specified). ☐ Fully photographed system and system plumbing. Pre-Startup ☐ Install brine line tubing. ☐ WCC STARTUP PROCEDURES | PAGE 1/3 Install meter cables.
  • Page 15 (Note, if necessary, valves may be temporarily re-programmed to actuate Progressive Service at lower flow rates, for confirmation of operation. This requires entering the system Master Programming Functionality. It also requires returning all set points to their previous levels when completed! Contact WCC for more details). ☐...
  • Page 16 Brine Tank Fill and Final Observations WCC STARTUP PROCEDURES | PG 3/3 ☐ Add salt to brine tank. How many lbs.?__________________________________________________________________________ ☐ Other thoughts/concerns about this system _________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________ ☐ Warranty Activated? Yes ☐ No ☐ If no, list any items that must be addressed prior to warranty activation:...
  • Page 17: Maintenance Procedures

    Check Inlet/Outlet Bypass Scheduled Maintenance Procedures ☐ Cycle Test Water Softener (Manual Regeneration) ☐ Check for Leaks ☐ Check Meters Counts Down Properly ☐ Check If Brine Line Draws Water ☐ WCC MAINTENANCE PROCEDURES | PAGE 1/2 Check Brine Line Refill...
  • Page 18 ☐ Perform Any Work Covered by Warranty (If Applicable, see notes) ☐ Include 12 postage-paid water sample bottles per year, plus testing by WCC lab (if needed) (Results will include testing for hardness, iron, TDS, pH) ☐ Re-Examine Water Quality Levels (Hardness)
  • Page 19: Service

    An Employee-Owned Company SERVICE You must keep salt in the tank. The salt tank operates best when the salt level is below half full. If the tank is filled more than halfway, salt bridging may occur. The salt pellets wedge against each other and do not fall into the water at the bottom. Bridging will eventually provide no salt to make brine. The softener will re-charge but not recondition the media.
  • Page 20 Breaking a Salt Bridge...
  • Page 22: Troubleshooting

    WS1 & WS1.25 Drawings & Service Manual Troubleshooting TC control valves do not have meters so shaded ares are not applicable for TC control valves Problem Possible Cause Solution a. Power Adapter unplugged a. Connect power b. No electric power at outlet b.
  • Page 23 WS1 & WS1.25 Drawings & Service Manual Problem Possible Cause Solution a. Control valve has just been ser- a. Unplug power source jack from viced the printed circuit board (black wire) and plug back in or press button sequence to reset valves: TC valves (three buttons) press and hold SET and DOWN buttons for 3 seconds.
  • Page 24 WS1.25EE WS1.25EE WATER WATER SPECIALIST SPECIALIST CONTROL CONTROL VALVE VALVE shown with optional bypass shown with optional bypass shown with optional bypass Certi ed to NSF/ANSI/CAN 61, NSF/ANSI 44 and 372. Certi ed to NSF/ANSI/CAN 61, NSF/ANSI 44 and 372. •...
  • Page 25 Water Specialist 1.25” EE Control Specifications Inlet/Outlet Fittings ................... ¾" to 1.5” NPS Cycles ...................... up to 6 Valve Material ................... Fiber Reinforced Composite Regeneration .................... Downflow FLOW RATES Service @15 psi drop (includes bypass and meter) ....34 gpm Backwash @ 25 psi drop (includes bypass) .......
  • Page 26 18 Inch Round Brine Tanks Clack's 18 inch blow molded round brine tanks offer a refreshing look in the residential and light commercial brine tank eld. Durable materials and the latest in plastic processing technology provide trouble-free performance. Ultraviolet inhibitors (UVI) are now standard in all tanks except black, which has a natural resistance to the sun's...
  • Page 27 Commercial/Industrial Rotationally Molded Brine Tanks Commercial and industrial water softeners require a large volume of brine during each regeneration. From a capacity of 95 gallons to 500 gallons, our Rotationally Molded Brine Tanks are built to last. Molded out of durable, chemically resistant high density polyethylene, their ⁄...
  • Page 28                                         ...

Table of Contents