LHN‑UC15L‑SIP | LHN‑UC15W‑SIP | AMN‑P15‑SIP
GPIO
Wire gauge
Ports and operating modes
Digital inputs
Digital outputs
Stored messages
Uploadable
Capacity
Supported file formats
Mechanical
Enclosure
Material
Dimension (HxWxD) (mm)
Dimension (HxWXD) (in)
Weight (g)
Weight (lb)
Ingress Protection (IP)
Color
DIN rail adapter
Material
Environmental
Climatic conditions
Operating temperature (°C)
Operating temperature (°F)
Bosch Security Systems B.V.
AWG 28 — AWG 14
1x supervised GPI, 1x GPO
Open: >2 V
Off: 1.25 V — 2 V
On: 0.75 V — 1.25 V
Short: < 0.75 V
Maximum: 48 V
On: Output switched to GND, max.
48 V/500 mA
Off: Open collector (>10 MΩ to GND)
Via web-GUI
300 MB
WAV, channels: mono, stereo; sampling rates:
44.1 kHz, 48 kHz
MP3, channels: mono, stereo; sampling rates:
44.1 kHz, 48 kHz
Ogg Vorbis, channels: mono, stereo; sampling
rates: 44.1 kHz, 48 kHz
Opus, channels: mono, stereo; sampling
rates: 44.1 kHz, 48 kHz
Acrylonitrile Butadiene Styrene (ABS)
92 mm x 146 mm x 40 mm
3.62 in x 5.75 in x 1.57 in
215 g
0.474 lb
IP30
Black
Aluminum
-40 °C — 55 °C
-40 °F — 131 °F
User manual
Technical data | en
2023.02 | V01 | F.01U.389.835
49