Camera System Adjustment; Hall Adjustment - Sony EVI-HD7V Service Manual

Hd color video camera
Hide thumbs Also See for EVI-HD7V:
Table of Contents

Advertisement

Address
Initial value
NTSC
EF
00
F0
00
F1
00
F2
00
F3
00
F4
00
F5
00
F6
00
F7 to FB
FC
2C
FD
C0
FE
59
FF
00

2-3. Camera System Adjustment

Check that the data of page:0, address:10 is "00".

2-3-1. Hall Adjustment

For detecting the position of lens iris and ND fi lter, adjust the hall AMP gain and offset.
Subject:
Not required
Measurement point:
Displayed data of page:1 (*1)
Measuring equipment:
Remote commander RM-95
Adjustment page:
6F
Adjustment address:
13 to 1B
Specifi cations
Specifi cation 1:
D6 to DA
Specifi cation 2:
26 to 2A
Specifi cation 3:
D6 to DA
Specifi cation 4:
26 to 2A
*1:
The right four digits of the page:1 displayed data of the remote commander RM-95.
1: XX:XX
IRIS displayed data
ND displayed data
n
If reading/writing data on page 6F, set data:06 to page:0, address:10, and then select page F. By this data
setting, the page 6F can be selected.
After the data reading/writing fi nished, return the data on page:0, address:10 to "00".
EVI-HD7V
Remark
PAL
00
Image Sensor Output 2ch Matching Adjustment
(Refer to Section 2-3-3.)
00
00
00
00
00
00
00
Fixed data-1 (Initialized data)
2C
AWB Adjustment (Refer to Section 2-3-12.)
C0
59
00
2-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evi-hd3v

Table of Contents