SERVICE MANUAL
Ver. 1.0 2009.02
• HS-AC1 is attached to HS-MB1.
Please refer to service manual of
HS-AC1 for information on HS-AC1.
Input and output terminals
RJ45: T568B Terminated. ABE (only for connection to HS-KP1
(Keypad))
(A DC 19.5 V included)
CD (only for connection to HS-WV1
(AV Wall Port))
(C DC 19.5 V included)
F (only for connection to CAV-CVB1
(Component Video Balun))
(DC 10 V included)
GH (only for connection to HS-WD1
(DIGITAL MEDIA Wall Port))
(G DC 19.5 V included)
40 pin fl at terminals:
For IDE cable (with pin 20 opening) only
(For stack connection only)
Pin jack video in:
For camera 1, 2 NTSC 75 ohms terminal
DC IN:
HS-AC1 only (not supplied)
10 V: by JEITA TYPE4 Jacks
19.5 V: by JEITA TYPE5 Jacks
DB1, DB2, CHIME:
Wire requirements: Copper Wire AWG 26 - 18
Outer diameter: 3 mm (0.12 inches), maximum
Strip away: 10 mm (0.4 inches)
RS-232C (DB9 Straight): For stack connection and service only
Sony Corporation
9-889-410-01
2009B04-1
Audio&Video Business Group
©
2009.02
Published by Sony Techno Create Corporation
SPECIFICATIONS
GENERAL
DC Power consumption (when HS-KP1, HS-WV1, HS-WA1,HS-WD1,
and CAV-CVB1 are not connected):
* Use DC 19.5 V for HS-KP1, HS-WV1, HS-WA1, HS-WD1, and
CAV-CVB1.
For details, refer to the instruction manual of each product.
* Use DC 10 V only for HS-MB1. Even if you connect the DC 10 V to
HS-MB1, no power is supplied HS-KP1, HS-WV1, HS-WA1, HS-
WD1, or CAV-CVB1.
Operating temperature:
Storage temperature:
Dimensions:
Mass:
Supplied accessories
HS-AC1
AC power cord (mains lead)
Installer's manual
Design and specifi cations are subject to change without notice.
HS-MB1
US Model
DC 19.5 V /0.6 A (ZONE 1 - 4), 0.1 A
(ZONE 5 - 8)
DC 10 V /0.3 A
0 ˚C - 30 ˚C (32 ˚F - 86 ˚F)
–20 °C - 60 °C (–4 °F - 140 °F)
290 × 250 × 55 mm
1
7
3
(11
/
× 9
/
× 21
/
inches) (w/h/d)
22
8
4
2 kg (4 lbs 6 1/2 oz.)
DISTRIBUTION PANEL