3-38. RP HEAD (for DV) Lista Sensitivity Adjustment

SPEC.
Sensitivity: 130±30 (mV/µm)
VTR MODE
PLAYBACK
! ATF (R/P-R)
TEST POINT
" H SW (R/P-R)
# GND
ADJUSTMENT
SERVO Adjustment Menu: "A18: RPR GAIN DV"
TAPE
VFM3000EDS
1.
Set the LISTA software in 25M Mode. 25M and 50M mode can be changed by "0" key on the key board.
2.
Select the item "A18: RPR GAIN DV" in the "SERVO ADJUST" menu.
3.
Playback a DV LISTA alignment tape (VFM3000EDS).
4.
Select the LISTA (6) ATF Error Signal Monitor so that the screen of <ATF Error Signal monitor> appears. (refer
to figure 3-38-2) Then press Enter to start the software.
TP6801 RF (F8)
TP6802 RF (F8)
TG102 RF (F8)
Figure 3-38-1
In case "ATF Error Signal Monitor"
or "sensitivity Measurement" is selected.
Figure 3-38-2
Select for sensitivity detection
Select for Linearity adjustment
Select for sensitivity
adjustment
MECH-37