Page 2
Introduction Safety instructions SIMATIC Product overview S7-1500 CPU 1511-1 PN Connecting up (6ES7511-1AL03-0AB0) Interrupts, error messages, diagnostics and system alarms Equipment Manual Technical specifications Dimensional drawing 11/2022 A5E40869673-AC...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of contents Introduction............................Guide documentation S7-1500/ET 200MP................. 1.1.1 Information classes S7-1500/ET 200MP................1.1.2 SIMATIC Technical Documentation..................Safety instructions..........................10 Security information......................10 Product overview..........................11 New functions........................11 Application........................12 Hardware properties......................19 Firmware functions......................21 Operating and display elements..................25 3.5.1 Front view of the CPU with closed front panel..............
Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP).
This arrangement enables you to access the specific content you require. Changes and supplements to the manuals are documented in a Product Information. You can download the documentation free of charge from the Internet (https://support.industry.siemens.com/cs/ww/en/view/109742691). Basic information The System Manual and Getting Started describe in detail the configuration, installation, wiring and commissioning of the SIMATIC S7-1500 and ET 200MP systems.
Product Information takes precedence over the device and system manuals. You can find the latest Product Information on the S7-1500 and ET 200MP systems on the Internet (https://support.industry.siemens.com/cs/de/en/view/68052815). Manual Collection S7-1500/ET 200MP The Manual Collection contains the complete documentation on the SIMATIC S7‑1500 automation system and the ET 200MP distributed I/O system gathered together in one file.
Page 8
Online Support: Industry Online Support International https://support.industry.siemens.com/cs/ww/en/view/109742705 Watch this short video to find out where you can find the overview directly in Siemens Industry Online Support and how to use Siemens Industry Online Support on your mobile device: Quick introduction to the technical documentation of automation products per video ( https://support.industry.siemens.com/cs/us/en/view/109780491...
Page 9
Introduction 1.1 Guide documentation S7-1500/ET 200MP You can find the application examples on the Internet. (https://support.industry.siemens.com/cs/ww/en/ps/ae) CPU 1511-1 PN (6ES7511-1AL03-0AB0) Equipment Manual, 11/2022, A5E40869673-AC...
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
Product overview New functions This section contains an overview of the most important new firmware functions of the CPU compared to the predecessor CPU (V2.9). New functions of the CPU in firmware version V3.0 New functions Applications Customer benefits Communication of the CPU Network Management Protocol A simple configuration option is available for Can be enabled/disabled in the CPU proper...
Reference You can find an overview of all new functions, improvements and revisions in the respective firmware versions on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109478459). Application SIMATIC S7-1500 is the modular control system for a wide variety of automation applications in discrete automation.
Page 13
Product overview 3.2 Application SIMATIC S7-1500 is the cost-effective and convenient solution for a broad range of tasks and offers the following advantages: • Modular, fanless design • Simple realization of distributed structures • User-friendly handling Areas of application of the SIMATIC S7-1500 automation system include, for example: •...
Page 14
Product overview 3.2 Application Performance segments of standard CPUs The CPUs can be used for smaller and mid-range applications, as well as for the high-end range of machine and plant automation. Table 3-1 Standard CPUs Performance segment PROFIBUS PROFINET PROFINET Basic Work Processing interfaces...
Page 15
Product overview 3.2 Application The higher the risks and costs of a production downtime, the more worthwhile the use of a redundant system. The avoidance of production downtimes compensates for the generally higher investment costs. Table 3-2 Redundant CPUs Performance segment PROFIBUS PROFINET PROFINET...
Page 16
Product overview 3.2 Application Performance segments of technology CPUs The technology CPUs can be used for low and mid-range applications, as well as for the high- end range of machine and plant automation. Because of their extended motion control functions, they are primarily used for drive control. Table 3-4 Technology CPUs Performance segment PROFIBUS...
Page 17
Product overview 3.2 Application Additional password protection for F-configuration and F-program is set up for IT security. Table 3-5 Fail-safe CPUs Performance segment PROFIBUS PROFINET PROFINET Basic Work memory Pro interfaces IO RT/IRT IO RT inter PROFINET cessing interfaces face functional time for bit opera...
Page 18
Detailed information about this and a multitude of other display functions is available in the SIMATIC S7-1500 Display Simu lator (https://support.industry.siemens.com/cs/ww/en/view/109761758). Uniform front connectors for all modules and integrated potential jumpers for flexible formation of potential groups simplify storage.
Product overview 3.3 Hardware properties connection cables and I/O modules), as well as easy wiring inside the control cabinet (flexible connection consisting of front connectors with assembled single conductors). System diagnostics and alarms Integrated system diagnostics is activated by default for the CPUs. The different types of diagnostics are configured instead of programmed.
Page 20
S7‑1500, ET 200MP system manu display with plain text information. The display provides information on order numbers, firmware version and (http://support.automation. siemens. serial numbers of all connected modules. In addition, com/WW/view/en/59191792) you can set the IP address of the CPU and carry out fur...
IO controller and is used in the process as an intelligent pre-processing unit of sub-processes Accessories You can find information on "Accessories/spare parts" in the S7-1500, ET 200MP system manual (http://support.automation.siemens.com/WW/view/en/59191792). Firmware functions Functions The CPU 1511‑1 PN supports the following firmware functions: Function...
Page 22
Function manual for trace and logic functionality and/or optimizing the user program. analyzer function You record device tags and evaluate the recordings with (https://support.industry.siemens. the trace and logic analyzer function. Tags are, for com/cs/ww/en/view/64897128) example, drive parameters or system and user tags of a CPU.
Page 23
It is possible to establish redundant networks via the PROFINET function manual Protocol) Media Redundancy Protocol. Redundant transmission (https://support.industry.siemens. links (ring topology) ensure that an alternative commu com/cs/ww/en/view/49948856) nication path is made available if a transmission link fails. The PROFINET devices that are part of this redundant net...
Page 24
Integrated closed-loop con • PID Compact (continuous PID controller) PID control function manual trol functionality (https://support.industry.siemens. • PID 3Step (step controller for integrating actuators) com/cs/ww/en/view/108210036) • PID Temp (temperature controller for heating and cooling with two separate actuators)
Product overview 3.5 Operating and display elements Operating and display elements 3.5.1 Front view of the CPU with closed front panel The following figure shows the front view of the CPU 1511-1 PN. ① LEDs for the current operating mode and diagnostics status of the CPU ②...
Page 26
(local lock) and assign a password for the display. You can find additional information on the display, configurable protection levels and local locks in the S7-1500, ET 200MP (http://support.automation.siemens.com/WW/view/en/59191792) system manual. Reference You will find detailed information on the individual display options, a training course and a simulation of the available menu commands in the SIMATIC S7-1500 Display Simulator (https://support.industry.siemens.com/cs/ww/en/view/109761758).
Figure 3-4 View of the CPU 1511-1 PN (without front panel) – front NOTE Removing the display Only remove the display if it is faulty. You can find information on removing and replacing displays in the S7‑1500, ET 200MP system manual (https://support.industry.siemens.com/cs/ww/en/view/59191792). CPU 1511-1 PN (6ES7511-1AL03-0AB0) Equipment Manual, 11/2022, A5E40869673-AC...
Product overview 3.5 Operating and display elements ① Slot for the SIMATIC memory card ② PROFINET IO interface (X1) with 2 ports ③ Connection for supply voltage ④ Fixing screw Figure 3-5 View of the CPU 1511-1 PN – bottom 3.5.3 Rear view of the CPU The following figure shows the connection elements on the back of the CPU 1511-1 PN.
You can find additional information in the yellow. memory card): S7‑1500/ET 200MP system manual. 2. Press the operating mode button (https://support.industry.siemens. STOP until the RUN/STOP LED lights com/cs/ww/den/view/59191792) up for the 2nd time and remains con tinuously lit (this takes three seconds).
Connecting up This section provides information on the pin assignment of the individual interfaces and the block diagram of the CPU. 24 V DC supply voltage (X80) The connector for the power supply is plugged in when the CPU ships from the factory. The following table shows the signal names and the descriptions of the pin assignment of the 24 V DC supply voltage.
Page 31
You need a screwdriver (max. blade width 2.5 mm) to remove the PROFINET plug. Remove display You can find a description of how to remove and replace the display in the S7‑1500, ET 200MP (http://support.automation.siemens.com/WW/view/en/59191792) system manual. Reference You can find additional information on the topics of "Connecting the CPU" and "Accessories/spare parts"...
Page 32
Connecting up The table below shows how the MAC addresses are assigned. Table 4-2 Assignment of the MAC addresses Assignment Labeling MAC address 1 PROFINET interface X1 • Front, lasered (visible in STEP 7 in accessible devices) • Right side, lasered (start of number range) MAC address 2 Port X1 P1R (required for LLDP, for •...
Page 33
Connecting up ④ Backplane bus interface STOP ACTIVE LED (yellow) ⑤ Internal supply voltage RUN/STOP LED (green/yellow) SIMATIC memory card ERROR LED (red) PN X1 P1R PROFINET interface X1 Port 1 MAINT LED (yellow) PN X1 P2R PROFINET interface X1 Port 2 X1 P1, X1 P2 LED Link TX/RX Figure 4-2 Block diagram of the CPU 1511-1 PN CPU 1511-1 PN (6ES7511-1AL03-0AB0)
The status and error displays of the CPU 1511-1 PN are described below. You will find additional information on "Interrupts" in the STEP 7 online help. You can find additional information on the topics of "Diagnostics" and "System alarms" in the Diagnostics (http://support.automation.siemens.com/WW/view/en/59192926) function manual. Status and error display of the CPU LED display The figure below shows the LED display of the CPU.
Page 35
Interrupts, error messages, diagnostics and system alarms 5.1 Status and error display of the CPU Meaning of the RUN/STOP, ERROR and MAINT LEDs The CPU has three LEDs for displaying the current operating mode and diagnostics status. The following table shows the meaning of the various combinations of colors for the RUN/STOP, ERROR and MAINT LEDs.
Page 36
Interrupts, error messages, diagnostics and system alarms 5.1 Status and error display of the CPU RUN/STOP LED ERROR LED MAINT LED Meaning Startup (CPU booting) LED flashes red LED flashes yellow LED flashes Test of LEDs during startup, inserting a module. yellow/green LED flashing test Meaning of LINK RX/TX LED...
Page 37
Interrupts, error messages, diagnostics and system alarms 5.1 Status and error display of the CPU STOP ACTIVE LED Meaning • The CPU is set to "STOP" mode using the display or programming device and not with the LED off STOP button on the device. •...
Technical specifications The following table shows the technical specifications as of 11/2022. You will find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/ww/en/pv/6ES7511-1AL03-0AB0/td?dl=en). Article number 6ES7511-1AL03-0AB0 General information Product type designation CPU 1511-1 PN HW functional status...
Page 39
Technical specifications Article number 6ES7511-1AL03-0AB0 Power consumption from the backplane bus 5.5 W (balanced) Power loss Power loss, typ. 7.5 W Memory Number of slots for SIMATIC memory card SIMATIC memory card required Work memory • integrated (for program) 300 kbyte integrated (for data) 1.5 Mbyte...
Page 40
Technical specifications Article number 6ES7511-1AL03-0AB0 • Number of DPV1 alarm OBs • Number of isochronous mode OBs • Number of technology synchronous alarm • Number of startup OBs Number of asynchronous error OBs • • Number of synchronous error OBs Number of diagnostic alarm OBs •...
Page 41
Technical specifications Article number 6ES7511-1AL03-0AB0 • per priority class, max. 64 kbyte; max. 16 KB per block Address area Number of IO modules 2 048; max. number of modules / submodules I/O address area Inputs 32 kbyte; All inputs are in the process image •...
Page 42
Technical specifications Article number 6ES7511-1AL03-0AB0 • in AS, master • in AS, slave • on Ethernet via NTP Interfaces Number of PROFINET interfaces 1. Interface Interface types RJ 45 (Ethernet) Yes; X1 • • Number of ports •...
Page 43
Technical specifications Article number 6ES7511-1AL03-0AB0 Update time for IRT – for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with iso chronous mode, the minimum update time of 500 µs of the isochronous OB is decisive –...
Page 44
Technical specifications Article number 6ES7511-1AL03-0AB0 • Number of connections reserved for ES/HMI/web • Number of connections via integrated interfaces Number of S7 routing paths • Redundancy mode • H-Sync forwarding Media redundancy Media redundancy only via 1st interface (X1) –...
Page 45
Technical specifications Article number 6ES7511-1AL03-0AB0 Web server • HTTP Yes; Standard and user pages HTTPS Yes; Standard and user pages • OPC UA • Runtime license required Yes; "Small" license required • OPC UA Client Yes; Data Access (registered Read/Write), Method Call –...
Page 46
Technical specifications Article number 6ES7511-1AL03-0AB0 – Number of sessions, max. – Number of accessible variables, max. 50 000 – Number of registerable nodes, max. 10 000 – Number of subscriptions per session, max. Sampling interval, min. 100 ms – – Publishing interval, min. 200 ms Number of server methods, max.
Page 47
Technical specifications Article number 6ES7511-1AL03-0AB0 • Status/control variable • Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters • Number of variables, max. of which status variables, max. 200; per job – – of which control variables, max. 200; per job Forcing ...
Page 48
Technical specifications Article number 6ES7511-1AL03-0AB0 – Number of positioning axes at motion control cycle of 8 ms (typical value) Controller • PID_Compact Yes; Universal PID controller with integrated optimization • PID_3Step Yes; PID controller with integrated optimization for valves • PID-Temp Yes;...
Page 49
Weight, approx. 336 g General technical specifications You can find information on the general technical specifications, such as standards and approvals, electromagnetic compatibility, protection class, etc., in the S7-1500, ET 200MP (http://support.automation.siemens.com/WW/view/en/59191792) system manual. CPU 1511-1 PN (6ES7511-1AL03-0AB0) Equipment Manual, 11/2022, A5E40869673-AC...
Dimensional drawing This section includes a dimensional drawing of the module on a mounting rail and a dimensional drawing with the front panel open. Always observe the specified dimensions for installation in cabinets, control rooms, etc. Dimensional drawings for CPU 1511-1 PN Figure A-1 Dimensional drawing of CPU 1511-1 PN, front and side views Figure A-2 Dimensional drawing of CPU 1511-1 PN, side view with front panel open CPU 1511-1 PN (6ES7511-1AL03-0AB0)