Download Print this page

NEC VT695 Control Commands page 24

Control commands
Hide thumbs Also See for VT695:

Advertisement

Example of acquisition
DATA03 DATA04 DATA05 DATA06: lamp's use of hours
50H
46H
00H
Calculator Procedure
1) Set calculator to HEX
2) Punch in DATA06 DATA05 DATA04 DATA03 (00004650)
3) Change from HEX to Decimal - value will change to 18000 seconds
Lamp's use of hours = 18000/3600 = 5 hours
* In case of acquiring the remaining time until lamp warning message starts to appear (in terms of specified
values)
03H 96H 00H 00H 02H 00H 08H A3H
Example of acquisition
DATA03 DATA04 DATA05 DATA06: Remaining time
40H
7EH
05H
Calculator Procedure
1) Set calculator to HEX
2) Punch in DATA06 DATA05 DATA04 DATA03 (00057E40)
3) Change from HEX to Decimal - value will change to 360000 seconds
Remaining time until lamp warning message starts to appear
= 360000/ 3600= 100 hours
050. REMOTE KEY CODE
**********************************************************************
Function:
This command sends remote control key codes of projector.
Command:
02H 0FH 00H 00H 02H DATA01 DATA02 CKS
Data Portion Contents
-------------------------------------------------------------------
DATA01 .. 02 : Remote control key code (Word type)
Key number DATA01 DATA02
--------------------------------------------
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
00H: 18000 seconds
00H: 360000 seconds
(*3)
01H
00H
POWER
02H
00H
POWER ON (!!)
03H
00H
POWER OFF (!!)
04H
00H
SOURCE (AUTO) (!!)
05H
00H
AUTO (!) (!!)
06H
00H
MENU (!!) (!!!)
07H
00H
UP (!!) (!!!)
08H
00H
DOWN (!!) (!!!)
09H
00H
RIGHT (!!) (!!!)
0AH
00H
LEFT (!!) (!!!)
0BH
00H
ENTER (!!) (!!!)
0CH
00H
CANCEL (!!) (!!!)
0DH
00H
HELP (!!) (!!!)
0EH
00H
POINTER
0FH
00H
MAGNIFY UP
Key name

Advertisement

loading