C-100
2-7.

CAPSULE HOLDER (17), CU25 CAPSULE ASSY

CAUTION
Take care so that you do not damage the CU25 capsule assy
with the wire terminal, etc. If you damage the CU25 capsule
assy, replace it with a new part. Also, take care so that solder
droplets do not attach to the CU25 capsule assy.
3 Remove the solder of short wire.
[black] (See Fig. C, H)
3 Remove the silicone, and then
remove the solder of the long wire.
[black] (See Fig. C, H)
Note 5: Attaching the silicone is not
necessary when assembling.
5 CU25 capsule assy
Note 4: Do not touch with your bare hands.
If this part is touched with bare
hands or if it is dirty, make sure to
wipe it with alcohol.
capsule side
1 two lock ace screws (M1.4) (L = 3.0 mm)
Note 1: When removing screws, it is not reused.
Be sure to replace them with new parts.
Note 2: When tightening screws, tighten
the below torque value.
tightening torque:
< Fig. C >
short wire [black]
long wire
[black]
SIDE-001
CU25 capsule assy
board side
< Fig. E >
Note 3: When installing screws, follow the installing
CU25 capsule assy
10
2 capsule
holder (17)
3 Remove the silicone, and then
< Fig. D >
short wire [black]
long wire
[black]
CU25 capsule assy
procedure in the numerical order given.
tightening torque:
SIDE-001
board side
1
SIDE-001 board side
4 screw (M1.4
3.5 mm)
(See Fig. E)
remove the solder of the long wire.
[black] (See Fig. D, H)
Note 5: Attaching the silicone is not
necessary when assembling.
Do not touch the portions within the dotted lines in the figure
below (including the wires connected to the capsule) with
your bare hands. If you do so, wipe your hands with alcohol.
Includes the capsule side portion and wire portion.
Make sure you do not touch these parts. If you do so, you
will not be able to use these parts. Make sure to replace
SIDE-002
them with new parts.
board side
SIDE-001
board side
connector side
4 screw (M1.4
(See Fig. E)
3 Remove the solder of short wire.
[black] (See Fig. D, H)
Note 6: Solder within the guide line.
Solder
lug
guide line
guide line
< CAUTION >
2
CU25 capsule assy
3.5 mm)
[black]

Advertisement