DIMENSIONS
RANGE HOOD - 30" (76.2 CM) AND 36" (91.4 CM)
VENTING REQUIREMENTS
Vent system must terminate to the outdoors.
Do not terminate the vent system in an attic or other enclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. Rigid metal vent is recommended.
The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has a damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening around the cap.
The size of the vent should be uniform.

Venting Methods

This range hood is factory set for venting through the roof or wall.
A 3¹⁄
" x 10" (8.3 cm x 25.4 cm) rectangular vent system is needed for installation (not included). The hood exhaust opening is
4
3¹⁄
" x 10" (8.3 cm x 25.4 cm). Vent system can terminate either through the roof or wall. To vent out of the top of the range hood and
4
through a wall, a 90° elbow is needed. See "Install Range Hood" section of your Owner's Manual for details of installing the damper.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.
Rear discharge
This range hood can be vented directly out the back using the 3¹⁄
a 3¹⁄
" x 10" (8.3 cm x 25.4 cm) rectangular vent system (not supplied). See "Install Range Hood" section of your Owner's Manual for
4
details of installing the damper.
Roof Venting
A
B
A. Roof cap
B. 3¹⁄
" x 10" (8.3 x 25.4 cm)
4
rectangular metal vent
" x 10" (8.3 cm x 25.4 cm) rectangular damper (supplied) along with
4
Wall Venting (top or rear discharge)
B
A. Wall cap
B. 3¹⁄
" x 10" (8.3 x 25.4 cm)
4
rectangular metal vent
A