List Of Electrical Parts - Sharp SJ-2047-GY Service Manual

Table of Contents

Advertisement

ITEMS
Thermostat
Defrost thermostat
Thermo. fuse
F-fan motor
R-fan motor
(R-fan fuse) 123
Defrost heater
Door switch
Damper thermostat
Defrost timer
Lamp socket (F/R)
F-lamp
R-lamp
R-fan thermo. R-fan thermo.
ass'y
R-fan thermo.heater RSS2
Compressor
Starting relay
Overload relay(Protector) 4TM757NFBYY
Capacitor
Running capacitor

LIST OF ELECTRICAL PARTS

TYPE NAME
MM1-8123
125V 6A
250V 3A
S101
250V 8A
SF70E
250V 10A
3R00044B
220-240V 50/60Hz
3R00122A
220-240V 50/60Hz
250V 2A
MM6-4197D
220-240V 353Ω
DSD-5
250V 0.25A
MM1-6170(SJ-2050,2060) —
MM1-6171(SJ-2047)
TMDF904FD2
220-240V
50/60Hz
250V 1A
240V 10W
240V 15W
S101
250V
350V,2W,10kΩ
GLY90AA
220-240V/ 50Hz
UH3003-7
250VAC 5µF
430VAC 5µF
RATING
(At normal notch)
ON/OFF : -19/-24˚C
Open/Close : 10/1˚C
Working temp. : 70˚C
Working with ø100 fan
Working with ø80 fan
Cut OFF 130˚C
150W at 230V with deodorizer
4 terminals push-button type
Open/Close : 3/-2˚C
Open/Close : 5/0˚C
Integration type
Cycle time : 10.8 / 9.0 hours(50/60Hz)
Delay time : 4.3/ 3.6 min.(50/60Hz)
E-12(Hard plastic body type)
E-12
E-12
8A
Open/ Close : 7/ 15 ˚C
1.1W at 230V
Cooling capacity : 220kcal/h(60Hz)
Main coil : 8.8Ω
Aux. coil : 14.2Ω
(at 25˚C)
14.0Ω
Open/ Close : 120/61˚C
—8.8Ω
5
SPECIFICATIONS
Main coil
Aux. coil
Common
SJ-2047
SJ-2050
SJ-2060

Hide quick links: