Adjusting the gas valves
Turn the control knobs to the lowest setting.
1.
Remove the control knobs from the gas valves. A
2.
flexible rubber sealing ring will be visible. Push down
with the tip of a screwdriver on the gas valve's
setting screw.
Never remove the sealing ring. Sealing rings
prevent liquids and dirt from finding their way into
the appliance and impairing its ability to function
properly.
If necessary, use a Torx screwdriver to adjust the
3.
bypass screws:
A: For ULPG the bypass screws must be tightened
properly.
B: For Natural Gas the bypass screws must finish
flush with the fitting.
Make sure that the flame does not go out and that
there are no flashbacks when you turn the control
knob between the highest and lowest setting.
Never remove the gas tap axle. In the event of damage,
the gas valve must be completely replaced.

Getting to know your appliance

*Getting to know your
appliance
B urner locations
G e t t i n g t o k n o w y o u r a p p l i a n c e
Pan supports
!
Control knobs
"
Economy burner with an output of up to 1 kW
#
Standard-output burner with an output of up to 1.75 kW
$
High-output burner with an output of up to 3 kW
%
Wok burner with an output of up to 4 kW
&
Dual-wok burner with an output of up to 5 kW
'