Item
Model
Compatible standards
Operating temperature range ー5℃〜+55℃ (average daily temperature of 35°C or less)
Operating humidity range
Operating environment
Storage temperature range
Altitude
Commercial-frequency withstand voltage
Insulation resistance
Compatible
Auxiliary power/Voltage input terminal
wiring
Current input and input/output terminal
Auxiliary power/Voltage input terminal screw 0.8〜1.0N ・ m
Tightening
Current input and input/output terminal screw 0.5〜0.6N ・ m
torque
Board installation screw
Weight
External dimensions (units: mm)
*1: 110 V and 220 V can be connected directly. An externally mounted voltage transformer (VT) is needed for voltages greater than those (primary voltage of up to a maximum of 6,600 V).
*2: 110 V, 220 V and 440 V can be connected directly. An externally mounted voltage transformer (VT) is needed for voltages greater than those (primary voltage of up to a maximum of 6,600 V).
*3: 63.5 V / 110 V - 277 V / 480 V can be connected directly. An externally mounted voltage transformer (VT) is needed for voltages greater than those (primary voltage of up to a maximum of 6,600 V).
*4: The settable primary current when using a 5A current sensor is as follows:
   5A、 6A、 7.5A、 8A、 10A、 12A、 15A、 20A、 25A、 30A、 40A、 50A、 60A、 75A、 80A、 100A、 120A、 150A、 200A、 250A、 300A、 400A、 500A、 600A、 750A、 800A、 1000A、 1200A、 1500A、 1600A、 2000A、 2500A、 3000A、  
   4000A、 5000A、 6000A
   (The CT primary side can be freely specified up to 6,000 A. However, the CT secondary side is fixed at 5 A.)
*5: Refer to "Specifications: Options (Split Current and 5A Current Sensors)" on p. 19 for the current sensor error ratios.
Specifications of MODBUS
Item
Physical interface
Communication protocol
Transmission method
Transmission wiring type
Baud rate
Data bit
Stop bit
Parity bit
Slave address
Response time
Terminating resistor
Transmission distance
Maximum connectable devices
Recommended cable
EMU4-HD1-MB
EMC:EN-61326-1:2006
Safety:EN-61010-1:2010
30%〜85% (no condensation)
ー10℃〜+60℃
2,000 m or less
Applies to all terminals ( excluding communication and frame GND terminals) , between external boards: 2,000V AC for 1 min.
Applies to all current/voltage inputs, between auxiliary powers: 2,000V AC for 1 min.
Applies to all current/voltage inputs and auxiliary power terminals,
between all digital/pulse input, pulse/alarm output and communication terminals: 2,000V AC for 1min.
In the same locations described above: 10 MΩ or more (500V DC)
AWG24-14 (Single/Stranded wire)
(Single wire: φ0.41 to φ1.62 mm,
Stranded wire: 0.13 to 2.0 mm
2
AWG22-14 (Single/Stranded wire) (Single wire: φ0.65 to φ1.62 mm; Stranded wire: 0.35 to 2.0
0.63N ・ m
0.3kg
75 ( W) ×90 ( H) ×75 ( D) ( Excluding protruding parts)
RTU Communication 
®
RS485 2wires half duplex
MODBUS
RTU mode
®
Asynchronous
Multi-drop bus (either directly on the trunk cable, forming a daisy-chain)
2400、 4800、 9600、 19200、 38400bps (default: 19,200 bps)
8
1,2 (default: 1)
ODD、 EVEN、 NONE (default:EVEN)
1〜255 ( FFh) (default: 1)
0: Broadcast
1s or shorter from completion of receiving query data to response transmission
120Ω 1/2W
1,200m
31 devices
SPEV (SB) -MPC-0.2×3P (Mitsubishi cable industries)
Specification
EMU4-BD1-MB
AWG24-16 (Single/Stranded wire)
(Single wire: φ0.52 to φ1.29 mm,
Stranded wire: 0.21 to 1.3 mm
2
0.8N ・ m
0.2kg
Specification
2
16