REMOVAL OF ANODE-CAP
OTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT, after
removing the anode.

REMOVING PROCEDURES

a
Turn up one side of the rubber cap in the
direction indicated by the arrow a.

HOW TO HANDLE AN ANODE-CAP

Don't scratch the surface of anode-caps with sharp shaped
material!
Don't press the rubber hardly not to damage inside of anode-
caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
Don't turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or damage the rubber.
All manuals and user guides at all-guides.com
b
2 Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow b.
c
Anode Button
3 When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning up
the rubber cap and pulling up it in the
direction of the arrow c.