TOOLS YOU WILL NEED
(x2)
10" ADJUSTABLE WRENCHES
LEVEL
FLAT BLADE SCREWDRIVER
8" PIPE WRENCH
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
SLIP JOINT PLIERS
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
MATERIALS YOU WILL NEED
4" DIA. METAL
ELBOW
4" DUCT
(IF NEEDED)
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
(IF NEEDED.)
PIPE
EXHAUST
COMPOUND
SOAP SOLUTION
HOOD
FOR LEAK DETECTION
DUCT TAPE
SAFETY
GLASSES
GLOVES
FLEXIBLE GAS LINE CONNECTOR

Advertisement

loading

Summary of Contents for GE GFDN240GLWW

  • Page 1 TOOLS YOU WILL NEED (x2) SLIP JOINT PLIERS 10" ADJUSTABLE WRENCHES LEVEL FLAT BLADE SCREWDRIVER 8" PIPE WRENCH MATERIALS YOU WILL NEED 4" DIA. METAL DUCT 4" DIA. METAL (RECOMMENDED) ELBOW 4" DIA. FLEXIBLE METAL (SEMI-RIGID) UL LISTED TRANSITION DUCT 4"...
  • Page 2 TURN GAS DISCONNECT AND DISCARD OLD FLEXIBLE GAS CONNECTOR AND SHUT-OFF OLD DUCTING MATERIAL. VALVE TO THE REPLACE WITH NEW CSA(AGA) OFF POSITION. APPROVED FLEXIBLE GAS LINE CONNECTOR AND UL APPROVED TRANSITION DUCT. WALL INTERNAL DUCT OPENING 2-5/8" CHECK THAT EXHAUSE HOOD DAMPER OPENS AND CLOSES FREELY.
  • Page 3 Listed connector ANSI Z21.24 / CSA 6.10 FLARE NEW METAL FLEXIBLE GAS LINE CONNECTOR ADAPTER 3/8" NPT ELBOW ITEMS NOT SUPPLIED APPLY PIPE COMPOUND TO THE ADAPTER AND DRYER GAS INLET. Tighten the flexible gas line using two adjustable wrenches. ADAPTER 1/8"...
  • Page 4 IF LOCAL CODES PERMIT, AN EXTERNAL GROUND WIRE (NOT PROVIDED), WHICH MEETS LOCAL CODES, MAY BE ADDED BY ATTACHING TO THE GREEN GROUND SCREW ON THE REAR OF THE DRYER, AND TO A GROUNDED METAL COLD WATER PIPE OR OTHER ESTABLISHED GROUND.
  • Page 5 For straight line installation, connect the dryer exhaust to the external exhaust hood using duct tape or clamp. EXTERNAL DUCT OPENING DUCT TAPE OR DUCT CLAMP 4" METAL DUCT CUT TO PROPER LENGTH DUCT TAPE OR DUCT CLAMP NOTE: WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING.
  • Page 6 ELBOW REQUIRED ELBOWS REQUIRED DON’T DO NOT SIT DRYER ON FLEXIBLE EXHAUST DO NOT USE EXCESSIVE EXHAUST LENGTH DO NOT CRUSH FLEXIBLE EXHAUST AGAINST WALL LEVEL FRONT-TO-BACK 4 LEVELING LEGS LEVEL SIDE-TO-SIDE...
  • Page 7 REMOVE SCREW AND SAVE. REMOVE DESIRED KNOCKOUT (ONE ONLY). FIXING HOLE (13 1/4” for bottom venting) Cut the duct as shown and keep portion A. BEND TAB UP 45 Through the rear opening, locate the tab in the middle of the appliance base.
  • Page 8 EXHAUST CAN BE ADDED TO LEFT OR RIGHT SIDE TAPE CAUTION: Internal duct joints must be secured with tape, otherwise they may separate and cause a safety hazard. PL ATE (KIT WE1M454) DUCT TAPE...
  • Page 9: Materiales Necesarios

    TOOLS YOU WILL NEED (x2) SLIP JOINT PLIER 10" ADJUSTABLE WRENCHES LEVEL FLAT BLADE SCREWDRIVER 8" PIPE WRENCH MATERIALES NECESARIOS CONDUCTO DE METAL DE 4” DE DIÁ (RECOMENDADO) ABRAZADERAS CODO DE METAL DE CONDUCTO DE 4" (2) DE 4” DE DIÁ. CONDUCTO DE TRANSICIÓN DE METAL ABRAZADERAS FLEXIBLE (SEMI RÍGIDO) DE 4”...
  • Page 10 DESCONECTE Y ELIMINE EL CONECTOR DE GAS FLEXIBLE ANTIGUO Y LOS CONDUCTOS VIEJOS. GIRE LA VÁLVULA REEMPLÁCELOS CON DE CIERRE DE GAS UN NUEVO CONECTOR A LA POSICIÓN OFF DE LÍNEA DE GAS FLEXIBLE (APAGADO) APROBADO POR CSA (AGA) Y UN CONDUCTO DE TRANSICIÓN APROBADO POR UL.
  • Page 11 Conector aprobado ANSI Z21.24 / CSA 6.10 EXTREMO ABOCINADO CONECTOR NUEVO DE LÍNEA DE GAS DE METAL FLEXIBLE ADAPTADOR NPT DE 3/8” CODO ITEMS NOT SUPPLIED APLIQUE COMPUESTO PARA TUBERÍA AL ADAPTADOR Y A LA ENTRADA DE GAS DE LA SECADORA. Ajuste la tubería flexible de gas utilizando dos llaves ajustables.
  • Page 12 SI LO PERMITEN LOS CÓDIGOS LOCALES, PUEDE AGREGARSE UN CABLE A TIERRA EXTERNO (NO PROVISTO), QUE CUMPLA CON LOS CÓDIGOS LOCALES, SUJETÁNDOLO AL TORNILLO VERDE DE CONEXIÓN A TIERRA EN LA PARTE TRASERA DE LA SECADORA, Y A LA TUBERÍA DE AGUA FRÍA DE METAL CON CONEXIÓN A TIERRA U OTRA CONEXIÓN A TIERRA ESTABLECIDA.
  • Page 13 Para una instalación en línea recta, conecte la salida de la secadora a la campana de salida al exterior con cinta aislante o una abrazadera. ABERTURA DE CONDUCTO EXTERIOR CINTA AISLANTE O ABRAZADERA DE CONDUCTO CONDUCTO DE METAL DE 4” CORTADO CON LA LONGITUD ADECUADA CINTA AISLANTE O ABRAZADERA DE CONDUCTO...
  • Page 14 CODO NECESARIO QUÉ NO HACER NO COLOQUE LA SECADORA SOBRE UNA SALIDA FLEXIBLE NO UTILICE UNA LONGITUD DE SALIDA EXCESIVA NO APLASTE LA SALIDA FLEXIBLE CONTRA LA PARED NIVELAR FRENTE A PARTE TRASERA 4 PATAS DE NIVELACIÓN QUÉ ACER CODOS NECESARIOS NIVELAR LADO A LADO...
  • Page 15 QUITE EL TORNILLO Y CONSÉRVELO QUITE EL RECORTE DESEADO (SÓLO UNO) Despegue y quite el recorte inferior, derecho o izquierdo, según corresponda. Quite el tornillo ubicado dentro del conducto de salida de la secadora y consérvelo. Saque el conducto de la secadora. (13 1/4”...
  • Page 16 LA SALIDA PUEDE AGREGARSE A LOS LADOS DERECHO O IZQUIERDO CINTA PRECAUCIÓN: Las juntas del conducto interno deben sujetarse con cinta; caso contrario, pueden separarse y provocar un riesgo de seguridad. PLACA (KIT WE1M454) CINTA AISLANTE...