Fig. 27: Removing / Installing The Air Suction Branch; Table 27: Tightening Torque (27027) - ABB HT582011 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-M axial
8 Disassembly and assembly / 8.3 Removing / Installing air-inlets
Removing the air suction branch
Disconnect all air lines according to the instructions of the enginebuilder.
u
Dismantle insulation as far as necessary.
u
Fig. 27: Removing / installing the air suction branch
1. Loop lifting gear around air suction branch.
2. Loosen and remove the nuts (72027) with washers (72028).
Remove and put down the air suction branch.
u
Installing the air suction branch
The installation of the air suction branch is carried out in reverse order.
Tighten nuts (72027) to the specified tightening torque.
u
Part number
27027
Table 27: Tightening torque (27027)
© Copyright 2017 ABB. All rights reserved.
A170-M
M18
170 Nm
HZTL4033_DE
A175-M
M20
220 Nm
Revision B
December 2017

Advertisement

Table of Contents
loading

This manual is also suitable for:

A175-m66

Table of Contents