HIKVISION DS-2TD3017T-3/V User Manual

HIKVISION DS-2TD3017T-3/V User Manual

Thermographic cube camera
Table of Contents

Advertisement

Quick Links

Thermographic Cube Camera
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for HIKVISION DS-2TD3017T-3/V

  • Page 1 Thermographic Cube Camera User Manual...
  • Page 2 INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
  • Page 3 Thermographic Cube Camera User Manual PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.
  • Page 4 Thermographic Cube Camera User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or could Danger result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, Caution could result in equipment damage, data loss, performance...
  • Page 5 Thermographic Cube Camera User Manual Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. Laws and Regulations ● In the use of the product, you must be in strict compliance with the electrical safety regulations of the nation and region.
  • Page 6 Thermographic Cube Camera User Manual example, in the case of some lithium battery types). ● DO NOT dispose of the battery into fire or a hot oven, or mechanically crush or cut the battery, which may result in an explosion. ●...
  • Page 7 Thermographic Cube Camera User Manual liquids, such as vases, shall be placed on the equipment. ● No naked flame sources, such as lighted candles, should be placed on the equipment. ● Provide a surge suppressor at the inlet opening of the equipment under special conditions such as the mountain top, iron tower, and forest.
  • Page 8: Table Of Contents

    Thermographic Cube Camera User Manual Contents Chapter 1 Overview........................1 1.1 Brief Description ........................1 1.2 Function ..........................1 Chapter 2 Device Activation and Accessing ................. 2 2.1 Activate the Device via SADP ....................2 2.2 Activate the Device via Browser ................... 2 2.3 Login ............................
  • Page 9 Thermographic Cube Camera User Manual 5.2.4 Notify Surveillance Center ..................20 5.2.5 Trigger Recording ..................... 20 5.2.6 Set Audible Alarm Output ..................20 Chapter 6 Live View ........................21 6.1 Live View Parameters ......................21 6.1.1 Window Proportion ....................21 6.1.2 Live View Stream Type .....................
  • Page 10 Thermographic Cube Camera User Manual 7.2.5 White Balance ......................28 7.2.6 DNR ........................... 29 7.2.7 Gray Scale ......................... 29 7.2.8 Set Palette ........................ 30 7.2.9 Set Target Enhancement ..................30 7.2.10 Set Palette Range ....................30 7.2.11 Mirror ........................31 7.2.12 Video Standard .......................
  • Page 11 Thermographic Cube Camera User Manual 9.1.1 Multicast Discovery ....................42 9.2 Port............................42 9.3 Port Mapping ........................43 9.3.1 Set Auto Port Mapping..................... 43 9.3.2 Set Manual Port Mapping ..................44 9.3.3 Set Port Mapping on Router ..................44 9.4 Multicast ..........................45 9.5 SNMP ...........................
  • Page 12 Thermographic Cube Camera User Manual 10.11 Set RS-485 ........................54 10.12 Set Same Unit ........................55 10.13 Security ..........................55 10.13.1 Authentication...................... 55 10.13.2 Security Audit Log ....................56 10.13.3 Set IP Address Filter ..................... 56 10.13.4 Set HTTPS ......................57 10.13.5 Set IEEE 802.1X .....................
  • Page 13: Chapter 1 Overview

    Thermographic Cube Camera User Manual Chapter 1 Overview 1.1 Brief Description The Thermographic Cube Camera is a temperature measurement device which is equipped with a thermal lens. It is equipped with high-sensitivity IR detector and high-performance sensor. The device is able to measure object's temperature at a high accuracy in real time.
  • Page 14: Chapter 2 Device Activation And Accessing

    2.1 Activate the Device via SADP Search and activate the online devices via SADP software. Before You Start Access www.hikvision.com to get SADP software to install. Steps 1. Connect the device to network using the network cable. 2. Run SADP software to search the online devices.
  • Page 15: Login

    Thermographic Cube Camera User Manual Note The default IP address of the device is 192.168.1.64. You can set the IP address of the PC from 192.168.1.2 to 192.168.1.253 (except 192.168.1.64). For example, you can set the IP address of the PC to 192.168.1.100. 3.
  • Page 16: Illegal Login Lock

    Thermographic Cube Camera User Manual Operating System Web Browser Operation plug-in installation is not required. Display and operation of certain functions are restricted. For example, Playback and Picture are not available. For detailed restricted function, refer to the actual device. Plug-in installation is not required.
  • Page 17: Chapter 3 Temperature Measurement

    Thermographic Cube Camera User Manual Chapter 3 Temperature Measurement When you enable this function, the device measures the actual temperature of the scene. It alarms when temperature exceeds the temperature threshold value. 3.1 Notice This part introduces the notices of configuring temperature measurement function. ●...
  • Page 18: Thermometry Flow Chart

    Thermographic Cube Camera User Manual 3.2 Thermometry Flow Chart This part introduces the process of configuring temperature measurement. Figure 3-1 Thermometry Flow Chart...
  • Page 19: Automatic Thermography

    Thermographic Cube Camera User Manual 3.3 Automatic Thermography Configure the temperature measurement parameters and temperature measurement rules. The device can measure the actual temperature and output alarms when temperature exceeds the alarm threshold value. 3.3.1 Set Thermography Parameters Configure the parameters of temperature measurement. Steps 1.
  • Page 20: Set Normal Mode

    Thermographic Cube Camera User Manual improve the temperature measuring accuracy. Calibration Coefficient Check to enable it and set the value of calibration coefficient to get the temperature of the external window or optical material automatically. The setting range is 0 to 30. Note You can get the setting value from SDK software.
  • Page 21 Thermographic Cube Camera User Manual Note Select Alarm Mode as Temperature Measurement Alarm first in basic settings. Emissivity Set the emissivity of your target. The emissivity of each object is different. Distance The distance between the target and the device. Pre-Alarm Threshold When the temperature of target exceeds the pre-alarm threshold, and this status keeps more than Filtering Time, it triggers pre-alarm.
  • Page 22: Set Expert Mode

    Thermographic Cube Camera User Manual Set the rule color in alarm status. Alarm Output Select the alarm output channel. 5. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting linkage method. 6. Click Save. The maximum and minimum temperature will be displayed on the live view.
  • Page 23: Set Thermography Rule

    Thermographic Cube Camera User Manual 3.3.4 Set Thermography Rule Steps 1. Customize the rule name. 2. Select the rule type to Point, Line, or Area. Then draw a point, line, or area on the interface where the position to be measured. Point Please refer to Point Thermographyfor detailed configuration.
  • Page 24 Thermographic Cube Camera User Manual Line Thermography Configure the temperature measurement rule and monitor the maximum temperature of the line. Steps 1. Click and drag the mouse to draw a line in the live view interface. 2. Click and move the line to adjust the position. 3.
  • Page 25: Manual Thermography

    Thermographic Cube Camera User Manual alarm temperature as 50°C. The device sends pre-alarm when its temperature reaches 50°C and it alarms when its temperature reaches 55°C and only when the device temperature is lower than 52°C will the alarm be cancelled. Pre-Alarm Output and Alarm Output When the temperature of target exceeds the pre-alarm or alarm threshold, it triggers the pre- alarm or alarm output of the connected device.
  • Page 26: Chapter 4 Event And Alarm

    Thermographic Cube Camera User Manual Chapter 4 Event and Alarm This part introduces the configuration of events. The device takes certain response to triggered alarm. Certain events may not be supported by certain device models. 4.1 Set Video Tampering Alarm When the configured area is covered and cannot be monitored normally, the alarm is triggered and the device takes certain alarm response actions.
  • Page 27: Set Video Loss

    Thermographic Cube Camera User Manual 6. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting linkage method. 7. Click Save. 4.2 Set Video Loss This function can detect the video signal loss in time and trigger the linkage action. Steps 1.
  • Page 28 Thermographic Cube Camera User Manual Network The device is offline. Disconnected IP Address Conflicted The IP address of current device is same as that of other device in the network. Illegal Login Incorrect user name or password is entered. 3. Refer to Linkage Method Settings for setting linkage method. 4.
  • Page 29: Chapter 5 Arming Schedule And Alarm Linkage

    Thermographic Cube Camera User Manual Chapter 5 Arming Schedule and Alarm Linkage Arming schedule is a customized time period in which the device performs certain tasks. Alarm linkage is the response to the detected certain incident or target during the scheduled time. 5.1 Set Arming Schedule Set the valid time of the device tasks.
  • Page 30: Ftp/Nas/Memory Card Uploading

    Thermographic Cube Camera User Manual Automatic Alarm Set the automatic alarm parameters, then the device triggers an alarm output automatically in the set arming schedule. Steps 1. Set automatic alarm parameters. Alarm Output No. Select the alarm output No. according to the alarm interface connected to the external alarm device.
  • Page 31: Send Email

    Thermographic Cube Camera User Manual Refer to Set Memory Card for memory card storage configuration. 5.2.3 Send Email Check Send Email, and the device sends an email to the designated addresses with alarm information when an alarm event is detected. For email settings, refer to Set Email.
  • Page 32: Notify Surveillance Center

    Thermographic Cube Camera User Manual 5.2.4 Notify Surveillance Center Check Notify Surveillance Center, the alarm information is uploaded to the surveillance center when an alarm event is detected. 5.2.5 Trigger Recording The video will be recorded when the configured action/event is detected. Related recording settings should be done in advance.
  • Page 33: Chapter 6 Live View

    Thermographic Cube Camera User Manual Chapter 6 Live View It introduces the live view parameters, function icons and transmission parameters settings. 6.1 Live View Parameters The supported functions vary depending on the model. Note For multichannel devices, select the desired channel first before live view settings. 6.1.1 Window Proportion ●...
  • Page 34: View Previous/Next Page

    Thermographic Cube Camera User Manual 6.2 View Previous/Next Page When the number of channels surpasses that of live view window division, this function can switch live view among multiple channels. Click to switch live view among multiple channels. 6.3 Full Screen This function is used to view the image in full screen mode.
  • Page 35 Thermographic Cube Camera User Manual UDP is suitable for the unstable network environment that does not demand high video fluency. MULTICAST MULTICAST is suitable for the situation that there are multiple clients. You should set the multicast address for them before selection. HTTP HTTP is suitable for the situation that the third-party needs to get the stream from the device.
  • Page 36: Chapter 7 Video And Audio

    Thermographic Cube Camera User Manual Chapter 7 Video and Audio This part introduces the configuration of video and audio related parameters. 7.1 Video Settings This part introduces the settings of video parameters, such as, stream type, video encoding, and resolution. Go to setting page: Configuration →...
  • Page 37: Bitrate Type And Max. Bitrate

    Thermographic Cube Camera User Manual and storage. 7.1.4 Bitrate Type and Max. Bitrate Constant Bitrate It means that the stream is compressed and transmitted at a comparatively fixed bitrate. The compression speed is fast, but mosaic may occur on the image. Variable Bitrate It means that the device automatically adjust the bitrate under the set Max.
  • Page 38: Smoothing

    Thermographic Cube Camera User Manual standard. In comparison to H.264, it offers better video compression at the same resolution, frame rate and image quality. Profile This function means that under the same bitrate, the more complex the profile is, the higher the quality of the image is, and the requirement for network bandwidth is also higher.
  • Page 39: Set Roi

    Thermographic Cube Camera User Manual 7.1.10 Set ROI ROI (Region of Interest) encoding helps to assign more encoding resource to the region of interest, thus to increase the quality of the ROI whereas the background information is less focused. Before You Start Please check the video coding type.
  • Page 40: Image Adjustment

    Thermographic Cube Camera User Manual settings for different channels may be different. This part introduces all possible parameters among the channels. Click Default to restore settings. 7.2.1 Image Adjustment By adjusting the Brightness, and Contrast, the image can be best displayed. 7.2.2 Image Adjustment (Thermal Channel) You can optimize the image display effect of thermal channel by setting background correction and manual correction.
  • Page 41: Dnr

    Thermographic Cube Camera User Manual temperature according to the environment. Figure 7-1 White Balance 7.2.6 DNR Digital Noise Reduction is used to reduce the image noise and improve the image quality. Normal and Expert modes are selectable. Normal Set the DNR level to control the noise reduction degree. The higher level means stronger reduction degree.
  • Page 42: Set Palette

    Thermographic Cube Camera User Manual 7.2.8 Set Palette You can select the palette mode to display the thermal grayscale image to colored image. Steps 1. Go to Configuration → Image → Display Settings. 2. Select the thermal channel. 3. Select a palette mode in Image Enhancement according to your need. Result The live view displays the image with palette.
  • Page 43: Mirror

    Thermographic Cube Camera User Manual Manual In this mode, you can enter the temperature upper limit and lower limit manually. And the live view shows the palettes effect of the desired temperature section more detailed. 7.2.11 Mirror When the live view image is the reverse of the actual scene, this function helps to display the image normally.
  • Page 44: Set Privacy Mask

    Thermographic Cube Camera User Manual 7.4 Set Privacy Mask The function blocks certain areas in the live view to protect privacy. No matter how the device moves, the blocked scene will never be seen. Steps 1. Go to privacy mask setting page: Configuration → Image → Privacy Mask. 2.
  • Page 45: Set Manual Dpc (Defective Pixel Correction)

    Thermographic Cube Camera User Manual Normal Mode Disable picture in picture mode. Details Overlay Enable picture in picture mode. You can overlay the image of another Mode channel in the current channel. 3. Click Save. 7.7 Set Manual DPC (Defective Pixel Correction) If the amount of defective pixels in the image is comparatively small and accurate correction is needed, you can correct these pixels manually.
  • Page 46: Chapter 8 Video Recording And Picture Capture

    Thermographic Cube Camera User Manual Chapter 8 Video Recording and Picture Capture This part introduces the operations of capturing video clips and snapshots, playback, and downloading captured files. 8.1 Storage Settings This part introduces the configuration of several common storage paths. 8.1.1 Set Memory Card If you choose to store the files to memory card, make sure you insert and format the memory card in advance.
  • Page 47: Set Ftp

    Thermographic Cube Camera User Manual The saving path of network disk files. Mounting Type Select file system protocol according to the operation system. Enter user name and password of the net HDD to guarantee the security if SMB/CIFS is selected. 3.
  • Page 48: Video Recording

    Thermographic Cube Camera User Manual 1. Go to Configuration → Storage → Storage Management → Cloud Storage. 2. Check Enable Cloud Storage. 3. Set basic parameters. Protocol Version The protocol version of the cloud video manager. Server IP The IP address of the cloud video manager. It supports IPv4 address. Serve Port The port of the cloud video manager.
  • Page 49 Thermographic Cube Camera User Manual Note The record type is vary according to different models. Continuous The video will be recorded continuously according to the schedule. Motion When motion detection is enabled and trigger recording is selected as linkage method, object movement is recorded.
  • Page 50: Playback And Download Video

    Thermographic Cube Camera User Manual The recordings are deleted when they exceed the expired time. The expired time is configurable. Note that once the recordings are deleted, they can not be recovered. 7. Click Save. 8.2.2 Playback and Download Video You can search, playback and download the videos stored in the local storage or network storage.
  • Page 51: Capture Automatically

    Thermographic Cube Camera User Manual path. You can view and download the snapshots. 8.3.1 Capture Automatically This function can capture pictures automatically during configured time periods. Before You Start If event-triggered capture is required, you should configure related linkage methods in event settings.
  • Page 52 Thermographic Cube Camera User Manual 2. Select channel No. 3. Set search condition and click Search. The matched pictures showed in the file list. 4. Select the pictures then click Download to download them. Note Go to Configuration → Local, click Save snapshots when playback to change the saving path of pictures.
  • Page 53: Chapter 9 Network Settings

    Thermographic Cube Camera User Manual Chapter 9 Network Settings 9.1 TCP/IP TCP/IP settings must be properly configured before you operate the device over network. IPv4 and IPv6 are both supported. Both versions can be configured simultaneously without conflicting to each other. Go to Configuration →...
  • Page 54: Multicast Discovery

    Thermographic Cube Camera User Manual Manual Input IPv6 Address, IPv6 Subnet, IPv6 Default Gateway. Consult the network administrator for required information. It stands for maximum transmission unit. It is the size of the largest protocol data unit that can be communicated in a single network layer transaction. The valid value range of MTU is 1280 to 1500.
  • Page 55: Port Mapping

    Thermographic Cube Camera User Manual TCP-based full-duplex communication protocol port for plug-in free preview. Certificate verification is required to ensure the secure access. Note ● WebSocket Port and WebSockets Port are only supported by certain models. ● For device models that support that function, go to Configuration → Network → Advanced Settings →...
  • Page 56: Set Manual Port Mapping

    Thermographic Cube Camera User Manual 9.3.2 Set Manual Port Mapping Steps 1. Check Enable UPnP™, and choose a friendly name for the device, or you can use the default name. 2. Select the port mapping mode to Manual, and set the external port to be the same as the internal port.
  • Page 57: Multicast

    Thermographic Cube Camera User Manual Figure 9-1 Port Mapping on Router Note The port of the network camera cannot conflict with other ports. For example, some web management port of the router is 80. Change the camera port if it is the same as the management port.
  • Page 58: Snmp

    Thermographic Cube Camera User Manual 9.5 SNMP You can set the SNMP network management protocol to get the alarm event and exception messages in network transmission. Before You Start Before setting the SNMP, you should download the SNMP software and manage to receive the device information via SNMP port.
  • Page 59: Access To Device Via Pppoe Dial Up Connection

    Thermographic Cube Camera User Manual By Browsers Enter the domain name in the browser address bar to access the device. By Client Software Add domain name to the client software. Refer to the client manual for specific adding methods. 9.7 Access to Device via PPPoE Dial Up Connection This device supports the PPPoE auto dial-up function.
  • Page 60: Enable Hik-Connect Service On Camera

    Thermographic Cube Camera User Manual 9.8 Enable Hik-Connect Service on Camera Hik-Connect service should be enabled on your camera before using the service. You can enable the service through SADP software or Web browser. 9.8.1 Enable Hik-Connect Service via Web Browser Follow the following steps to enable Hik-Connect Service via Web Browser.
  • Page 61: Access Camera Via Hik-Connect

    1. Get and install Hik-Connect application by the following ways. Visit https://appstore.hikvision.com to download the application according to your mobile phone system.Visit the official site of our company. Then go to Support → Tools → Hikvision App Store.Scan the QR code below to download the application.
  • Page 62: Set Open Network Video Interface

    Thermographic Cube Camera User Manual 4. Select a protocol version and input related parameters. 5. Click Save. Register status turns to Online when the function is correctly set. 9.10 Set Open Network Video Interface If you need to access the device through Open Network Video Interface protocol, you can configure the user settings to enhance the network security.
  • Page 63: Chapter 10 System And Security

    Thermographic Cube Camera User Manual Chapter 10 System and Security It introduces system maintenance, system settings and security management, and explains how to configure relevant parameters. 10.1 View Device Information You can view device information, such as Device No., Model, Serial No. and Firmware Version. Enter Configuration →...
  • Page 64: Export Diagnose Information

    Thermographic Cube Camera User Manual 10.4 Export Diagnose Information Diagnose information includes running log, system information, hardware information. Go to Configuration → System → Maintenance → Upgrade & Maintenance, and click Diagnose Information to export diagnose information of the device. 10.5 Reboot You can reboot the device via browser.
  • Page 65: View Open Source Software License

    Thermographic Cube Camera User Manual 2. Choose one method to upgrade. Firmware Locate the exact path of the upgrade file. Firmware Directory Locate the directory which the upgrade file belongs to. 3. Click Browse to select the upgrade file. 4. Click Upgrade. 10.8 View Open Source Software License Go to Configuration →...
  • Page 66: Set Dst

    Thermographic Cube Camera User Manual Note Server Address is NTP server IP address. 5. Click Test to test server connection. 6. Click Save. 10.9.3 Set DST If the region where the device is located adopts Daylight Saving Time (DST), you can set this function.
  • Page 67: Set Same Unit

    Thermographic Cube Camera User Manual Note You should keep the parameters of the device and the computer or terminal all the same. 3. Click Save. 10.12 Set Same Unit Set the same temperature unit and distance unit. When you enable this function, the unit cannot be configured separately in other setting pages Steps 1.
  • Page 68: Security Audit Log

    Thermographic Cube Camera User Manual 10.13.2 Security Audit Log The security audit logs refer to the security operation logs. You can search and analyze the security log files of the device so as to find out the illegal intrusion and troubleshoot the security events. Security audit logs can be saved on device internal storage.
  • Page 69: Set Https

    Thermographic Cube Camera User Manual 5. Click Save. 10.13.4 Set HTTPS HTTPS is a network protocol that enables encrypted transmission and identity authentication, which improves the security of remote access. Steps 1. Go to Configuration → Network → Advanced Settings → HTTPS. 2.
  • Page 70: Set Ieee 802.1X

    Thermographic Cube Camera User Manual – Select Create the certificate request first and continue the installation. Click Browse and Install to import the certificate to the device. 6. Click Save. 10.13.5 Set IEEE 802.1X You can authenticate user permission of the connected device by setting IEEE 802.1X. Go to Configuration →...
  • Page 71 Thermographic Cube Camera User Manual different user levels. Caution To increase security of using the device on the network, please change the password of your account regularly. Changing the password every 3 months is recommended. If the device is used in high-risk environment, it is recommended that the password should be changed every month or week.
  • Page 72: Chapter 11 Appendix

    0.98 Hard Paperboard 0.90 White Paper 0.90 Water 0.96 11.2 Device Command Scan the following QR code to get device common serial port commands. Note that the command list contains the commonly used serial port commands for Hikvision thermal cameras.
  • Page 73: Device Communication Matrix

    Thermographic Cube Camera User Manual 11.3 Device Communication Matrix Scan the following QR code to get device communication matrix. Note that the matrix contains all communication ports of Hikvision thermal cameras.
  • Page 74 UD29962B...

This manual is also suitable for:

Ds-2td3017t-2/vDs-2ta21-3avf

Table of Contents