Troubleshooting

Problem
No heating
Water leaking
Filling Door jammed/ can not
close or open/ bounce up
Too less steam (< 45 g/min)
No Steam
No spray
Backplate damaged/ cracked
Descaling Instruction:
Published by Philips Consumer Lifestyle
Document No. : CSW-07-081-18052
Possible root cause
Soleplate
Mains Cord
ASO (for ASO version)
Water Tank Assy
Soleplate
Calc Collector Assy
Inlay Assy
Soleplate full of scale
Soleplate
Water Tank Assy
Backplate Assy
Exchange Cover and Soleplate Mtd Assy & Mains
Cord, apply Heat Sink Paste to Live and Neutral wire.
Exchange Mains Cord, apply Heat Sink Paste to Live
and Neutral wire.
Exchange ASO
Exchange Water Tank Assy
Exchange Cover and Soleplate Mtd Assy & Mains
Cord, apply Heat Sink Paste to Live and Neutral wire.
Exchange Calc Collector Assy
Exchange Inlay Assy
Refer to descalling instruction stated below
Exchange Cover and Soleplate Mtd Assy & Mains
Cord, apply Heat Sink Paste to Live and Neutral wire.
Exchange Water Tank Assy
Exchange Backplate Assy & Mains Cord, apply Heat
Sink Paste to Live and Neutral wire.