  • Page 1 IBM 17″ 1 U Flat Panel Monitor Console Kit Installation and Maintenance Guide...
  • Page 3 IBM 17″ 1 U Flat Panel Monitor Console Kit Installation and Maintenance Guide...
  • Page 4 Note: Before using this information and the product it supports, read the general information in Appendix B, “IBM Statement of Limited Warranty Z125-4753-07 11/2002,” on page 29 and the notices information in Appendix C, “Notices,” on page 47. First Edition (March 2004) ©...
  • Page 5: Table Of Contents

    Notices and statements used in this document . Chapter 2. Installing the Flat Panel Monitor Console Kit ..5 Installing the flat-panel monitor and keyboard tray Installing an optional console switch .
  • Page 6 IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide...
  • Page 7: Safety

    Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright IBM Corp. 2004...
  • Page 8 Läs säkerhetsinformationen innan du installerar den här produkten. Important: IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide All caution and danger statements in this documentation begin with a number. This number is used to cross reference an English caution or danger statement with translated versions of the caution or danger statement in the IBM NetBAY Rack Safety Information book.
  • Page 9 Statement 4: DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet. v Connect to properly wired outlets any equipment that will be attached to this product.
  • Page 10 IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide...
  • Page 11: Chapter 1. Introduction

    Inventory checklist Note: The illustrations in this documentation might differ slightly from your hardware. The IBM 17″ 1 U Flat Panel Monitor Console Kit comes with the following items: v One keyboard tray with built-in flat-panel monitor v Two outer rails v One rail-alignment spacer 1.
  • Page 12 IBM NetBAY Rack Safety Information book v This documentation The IBM 17″ 1 U Flat Panel Monitor Console Kit is also available with a U.S. or Japan thin keyboard. The following additional items come with these models: v One thin keyboard with built-in pointing device...
  • Page 13: Notices And Statements Used In This Document

    One 1.8-m (6-ft) power cord v One CD containing keyboard and mouse device drivers and keyboard documentation You might need the following tools to install the IBM 17″ 1 U Flat Panel Monitor Console Kit: v One utility knife or scissors...
  • Page 14 IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide...
  • Page 15: Chapter 2. Installing The Flat Panel Monitor Console Kit

    Chapter 2. Installing the Flat Panel Monitor Console Kit The Flat Panel Monitor Console Kit occupies 1 U of mounting space in a rack cabinet. If you have a NetBAY25, NetBAY42, NetBAY42 Enterprise, NetBAY22 with Rack Extension Kit, Netfinity rack cabinet, you can use the brackets that come with this kit to install an optional console switch in the same 1 U of space.
  • Page 16 2. If your tray has a thin keyboard installed, go to step 7 on page 8. IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide To Disconnect: 1. Turn everything OFF.
  • Page 17 Attention: Do not extend the keyboard feet. The flat-panel monitor screen might be damaged if the feet are extended when the monitor is closed. 4. Carefully lift the front of the flat-panel monitor and raise the monitor to the full upright position.
  • Page 18 Use the cage nuts or clip nuts from the miscellaneous hardware kit. Note: If you are planning to install an optional console switch, make sure that IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide Keyboard-and-mouse cable routing you install a cage nut or clip nut in the center-rear position shown shaded in the following illustration.
  • Page 19 Make sure that the slide-rail brackets extend outside of the rack-cabinet mounting flanges. Note: Do not install screws in the slide-rail bracket middle holes. These holes are for the thumbscrews on the front of the tray. Chapter 2. Installing the Flat Panel Monitor Console Kit...
  • Page 20 Tighten the front four screws; then, remove the spacer. Note: Do not tighten the four rear slide-rail bracket screws at this time. IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide are for the optional console-switch mounting brackets. Rail-alignment spacer...
  • Page 21 13. Extend the inner part of the outer rails; then, slide the ball-bearing assemblies forward to the front of the outer rails. Carefully slide the flat-panel monitor and keyboard tray into the ball-bearing assemblies in the rails. 14. Press the release latches; then, push the flat-panel monitor and keyboard tray completely into the rack.
  • Page 22 18. Fully extend the tray from the front of the rack cabinet; then, neatly route cables within the rack cabinet and secure them with cable straps along the way. IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide...
  • Page 23 See the keyboard documentation for information about operating the keyboard. Note: When the monitor and keyboard are not in use, if the rack cabinet is in a vibration-prone area, or during cabinet relocation, tighten the two thumbscrews on the front of the tray to secure the tray inside the rack cabinet.
  • Page 24: Installing An Optional Console Switch

    Note: The left-side bracket has a channel for you to route the power, video, IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide and keyboard-and-mouse cables. Make sure that you attach the brackets to the console switch so that the channel on the left-side bracket faces upward.
  • Page 25 2. Install the console switch behind the flat-panel monitor and keyboard tray using two screws from the miscellaneous hardware kit. Console switch screw 3. Route the power, video, and keyboard-and-mouse cables through the channel in the left-side bracket on the console switch; then, connect the video, keyboard, and mouse connectors to the console switch.
  • Page 26 IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide...
  • Page 27: Chapter 3. Hardware Maintenance Information

    Chapter 3. Hardware maintenance information This chapter contains information about IBM customer-replaceable units (CRUs) for the IBM 17″ 1 U Flat Panel Monitor Console Kit and instructions for replacement parts that are not installed during a typical installation. Customer-replaceable unit part numbers IBM CRU part numbers are subject to change without notice.
  • Page 28 89P8514 26K4103 6952300 36L8886 IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide Description IBM PS/2 Travel Keyboard with UltraNav, Japan keyboard Miscellaneous hardware kit (left and right console-switch brackets, cage nuts, clip nuts, screws, cable straps, keyboard cord clip)
  • Page 29: Replacing The Cable-Management Arm

    3. Remove the screw that attaches the cable-management arm to the outer slide-rail bracket. 4. Fully extend the monitor and keyboard tray; then, temporarily remove the keyboard-and-mouse, video, and power cables from the cable-management arm. Chapter 3. Hardware maintenance information...
  • Page 30 8. If you removed a console switch from behind the tray, reinstall it now. 9. Reconnect the keyboard, mouse, and video connectors to the server or console switch. 10. Connect power to the monitor. IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide...
  • Page 31: Replacing The Slide-Rail Assemblies

    4. Remove the screw that attaches the cable-management arm to the outer slide-rail bracket. 5. Fully extend the monitor and keyboard tray from the front of the rack cabinet; then, push in the release latch on each side of the tray and slide the monitor Chapter 3. Hardware maintenance information...
  • Page 32 7. Loosen the four rail-adjustment screws on both of the new outer slide-rail brackets; then, extend the brackets to their maximum outward adjustment. Rail-adjustment screws IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide Release latch...
  • Page 33 8. Adjust the outer slide-rail brackets to fit the depth of the rack cabinet; then, attach the front of the slide-rail brackets to the rack cabinet using four screws. Make sure that the slide-rail brackets extend outside of the rack-cabinet mounting flanges.
  • Page 34 14. Go to step 13 on page 11 for instructions for reinstalling the monitor and keyboard tray in the rack cabinet; then, install any other devices that you removed from the rack cabinet. IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide Rail-alignment spacer...
  • Page 35: Replacing The Keyboard

    4. Unscrew the thumbscrews; then, fully extend the monitor and keyboard tray. Remove the keyboard-and-mouse cable from the cable-management arm. 5. Carefully lift the front of the flat-panel monitor and raise the monitor to the full upright position. 6. Remove the old keyboard from the keyboard tray.
  • Page 36 IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide Keyboard-and-mouse cable routing...
  • Page 37: Appendix A. Getting Help And Technical Assistance

    If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. This appendix contains information about where to go for additional...
  • Page 38: Software Service And Support

    You can find service information for your IBM products, including supported options, at http://www.ibm.com/pc/support/. Software service and support Through IBM Support Line, you can get telephone assistance, for a fee, with usage, configuration, and software problems with xSeries servers, IntelliStation workstations, and appliances. For information about which products are supported by Support Line in your country or region, go to http://www.ibm.com/services/sl/products/.
  • Page 39: Copyright Ibm Corp

    Country-unique Terms, and Part 3 - Warranty Information. The terms of Part 2 replace or modify those of Part 1. The warranties provided by IBM in this Statement of Limited Warranty apply only to Machines you purchase for your use, and not for resale. The term “Machine”...
  • Page 40 If the Machine does not function as warranted during the warranty period, contact IBM or your reseller to obtain warranty service. If you do not register the Machine with IBM, you may be required to present proof of purchase as evidence of your entitlement to warranty service.
  • Page 41 Personal Data. Limitation of Liability IBM is responsible for loss of, or damage to, your Machine only while it is 1) in IBM’s possession or 2) in transit in those cases where IBM is responsible for the transportation charges.
  • Page 42: Part 2 - Country-Unique Terms

    ABOVE LIMITATION MAY NOT APPLY TO YOU. Governing Law Both you and IBM consent to the application of the laws of the country in which you acquired the Machine to govern, interpret, and enforce all of your and IBM’s rights, duties, and obligations arising from, or relating in any manner to, the subject matter of this Statement of Limited Warranty, without regard to conflict of law principles.
  • Page 43 Limitation of Liability: The following is added to this section: Where IBM is in breach of a condition or warranty implied by the Trade Practices Act 1974 or other similar legislation, IBM’s liability is limited to the repair or replacement of the goods or the supply of equivalent goods.
  • Page 44 IBM’s negligence; 2. as to any other actual damage arising in any situation involving nonperformance by IBM pursuant to, or in any way related to the subject of this Statement of Limited Warranty, the charge paid by you for the individual Machine that is the subject of the claim.
  • Page 45 Consumer Guarantees Act 1993 or other legislation which cannot be excluded or limited. The Consumer Guarantees Act 1993 will not apply in respect of any goods which IBM provides, if you require the goods for the purposes of a business as defined in that Act.
  • Page 46 State, you may obtain warranty service for that Machine in any of those countries from either (1) an IBM reseller approved to perform warranty service or (2) from IBM, provided the Machine has been announced and made available by IBM in the country in which you wish to obtain service.
  • Page 47 Commercial Court of Paris; 5) in Russia, all disputes arising out of or in relation to the interpretation, the violation, the termination, the nullity of the execution of this Statement of Limited Warranty shall be settled by Appendix B. IBM Statement of Limited Warranty Z125-4753-07 11/2002...
  • Page 48 598 (2) of the Austrian Code of Civil Procedure, the parties expressly waive the application of paragraph 595 (1) figure 7 of the Code. IBM may, however, institute proceedings in a competent court in the country of installation.
  • Page 49 (if IBM is at fault) or of such cause, for a maximum amount equal to the charges you paid for the Machine. For purposes of this item, the term “Machine”...
  • Page 50 In case IBM or your reseller is unable to repair an IBM Machine, you can alternatively ask for a partial refund as far as justified by the reduced value of the unrepaired Machine or ask for a cancellation of the respective agreement for such Machine and get your money refunded.
  • Page 51 The minimum warranty period for Machines is twelve months. In case IBM or your reseller is unable to repair an IBM Machine, you can alternatively ask for a partial refund as far as justified by the reduced value of the unrepaired Machine or ask for a cancellation of the respective agreement for such Machine and get your money refunded.
  • Page 52 For the purposes of this section, a “Default” means any act, statement, omission, or negligence on the part of IBM in connection with, or in relation to, the subject matter of this Statement of Limited Warranty in respect of which IBM is legally liable to you, whether in contract or tort.
  • Page 53: Part 3 - Warranty Information

    Worldwide * See “Types of Warranty Service” for the legend and explanations of warranty-service types. A warranty period of 3 years on parts and 1 year on labor means that IBM provides warranty service without charge for: Warranty Period Type of Warranty Service*...
  • Page 54 1. Customer Replaceable Unit (“CRU”) Service IBM will ship CRU parts to you for your replacement. If IBM instructs you to return the replaced CRU, you are responsible for returning it to IBM in accordance with IBM’s instructions. If you do not return the defective CRU, if IBM so instructs, within 30 days of your receipt of the replacement CRU, IBM may charge you for the replacement.
  • Page 55 To obtain warranty service contact IBM or your IBM reseller. In Canada or the United States, call 1-800-IBM-SERV (426-7378). In the EU countries, see the telephone numbers below. EU Country Telephone List Phone numbers are subject to change without notice.
  • Page 56 IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide...
  • Page 57: Appendix C. Notices

    Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk.
  • Page 58: Trademarks

    IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software may differ from its retail version (if available), and may not include user manuals or all program functionality.
  • Page 59: Industry Canada Class A Emission Compliance Statement

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to operate the equipment.
  • Page 60: Taiwanese Class A Warning Statement

    Taiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council for Interference (VCCI) statement IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide...
  • Page 61: Index

    3 danger 3 electronic emission 48 FCC, Class A 48 important 3 safety v outer slide rails, replacing 21 © Copyright IBM Corp. 2004 parts customer-replaceable unit (CRU) part numbers 17 inventory checklist 1 publications, ordering 27 replacing cable-management arm 19...
  • Page 62 IBM 17″ 1 U Flat Panel Monitor Console Kit: Installation and Maintenance Guide...
  • Page 64 Part Number: 02R2779 Printed in USA (1P) P/N: 02R2779...

Table of Contents