    1.2 Handling of acids ................5 We declare under our sole responsibility that the acid 1.3 Personal protection ..............5 applicator Spreader 30 starting from production number 0000 is in conformity with the relevant Union legislation 1.4 First aid instructions ..............6 Machinery Directive 2006/42/EC.
  • Page 3: Safety

    1. Safety • Always keep enough clean rinse water on hand. • Pump a large amount of clean water through the system before maintenance. Always handle acids with Spreader 4000 acid applicator is primarily intended for caution. Always use acceptable personal protective pumping and dosing fluid agricultural preservatives in equipment.
  • Page 4: First Aid Instructions

    1.5 Restrictions on use • The operator of the acid applicator must not be under the influence of narcotics, alcohol or powerful medications. Spreader 30 • In case of illness or disablement, the operation of Operating voltage 12 V the machine must be authorized by the attending Max.
  • Page 5: Assembly

    3. Assembly 3.2 Connecting cable (10m) 3.1 Pump connection The sequence of the pins of the cable connecting the pump to the controller: The pump unit should be mounted as near the tank as possible. This improves the functions of the pump 1.
  • Page 6: Controller Usage And Key Functions

    4. Controller usage and key functions As the controller is switched on using the on/off switch (1), the default settings are displayed in the 4.1 Controller buttons and their functions: following order: - The pulse rate of the flow, pulses/litre - The level of flow alarm, litres/minute - The hysteresis of flow alarm, litres/minute After this the controller enters the basic mode and is...
  • Page 7: Default Settings

    When the Shift button (7) is pressed and held down the 4.2 Default settings pump operates with full power regardless of the power adjustments and the position of the limit switch. Can be PULSE RATE used e.g. for removing air from the system. The pulse rate indicates the amount of pulses in one litre of liquid.
  • Page 8: Changing The Default Settings

    THE LEVEL OF HYSTERESIS The level of hysteresis indicates the amount of increase in the flow above the alarm level required to stop the alarm automatically. The default setting is 0,3 l/min. In the default setting mode, the flow alarm will be activated when the flow decreases below 0,5 l/min for more than five seconds.
  • Page 9: Taking Into Use

    5. Taking into use 5.1 Testing Connect the hoses between the pump unit and the Prior to acid pumping the system must be tested by suction pipe and between the pump unit and the pumping clean water through the pump. The testing is nozzles.
  • Page 10: Additional Equipment

    6. Additional equipment 7. Maintenance and storing The acid applicator must always be cleaned after use Different kinds of limit switches can be used to control by pumping clean water through the whole system. the operating of the Spreader applicators. There are External cleaning is also necessary.
  • Page 11: Trouble Shooting

    8. Trouble shooting Error Possible cause Solution The output is The valves are Change the valves. Error Possible cause Solution weak. worn out. The pump does The pump is out Check the power The counter Remove the not start. of power. cables and pressure is too possible block, check...
  • Page 12: Terms Of Guarantee

    The parts that have not been manufactured by the instructions provided by the manufacturer of the Happowa Oy, such as the circuit cards and electric preservative and other experts regarding the handling motors, are covered by the warranty of the supplier in and use of preservatives.
  • Page 13: Spare Parts

    322023 Spreader-ohjain Spreader controller Spreader-styrenhet 338027 Ohjaimen kiinnityskieli Controller fastener Klämma för styrenhet 337020 Pohjalevy, Spreader 30 Bottom plate Bottenplatta 328995 Klemmari A4 15-24 mm Clamp A4 15-24 mm Klämma A4 15-24 mm 111657 PVC-letku Ø 20 mm Pvc hose Ø 20 mm Pvc slang Ø...
  • Page 14 320018 337440 SH1211144 Konekilpi Tunnus Suomi English Svenska Kpl. SH1902152 Spreader 4000 tarra Code SH1211142 Varoitustarra 337027 Kansi 133020 Lukitusmutteri M6 157350 Kalvopumppu 2-mäntäinen 2-piston diaphragm pump 2-kolvs memranpump 133028 Aluslatta M6 157206 111651 Letkulähtö 12 mm Pvc-letku 12mm Hose coupling 12 mm Slangkoppling 12 mm 328945 Letkunkiristin13-20...
  • Page 15 157350 337460 337120 Moottori Tunnus Suomi English Svenska Kpl. 337120 Moottori 337126 Alempi pumpunpesä Code 337126 Alempi pumpunpesä 337122 Venttiilisarja 4 mäntää 337122 Venttiilisarja 4 mäntää 337124 Pumpun pääty 337122 Painekytkin Pressure switch Tryckbrytare 337124 Pumpun pääty 337122 Painekytkin 337124 Pumpun pääty Pump end mounting Pumpbotten...
  • Page 16 337006 337400 313289 Putkiteippi 133630 Kuusiokoloruuvi M6x40 337420 Putken kiinnikepari 13,5mm Tunnus Suomi English Svenska Kpl. Tunnus 133028 Suomi Aluslatta M6 English Svenska Kpl. 337108 Pikaliitinpistoke 3/8" 133020 Lukitusmutteri M6 Code Code 320032 Tynnyrisovite 1666 Kiinnityslatta 111651 Pvc-letku 12mm 313298 Viuhkasuutin 2,2 l/min 9508 328990 Letkunkiristin A4 12-22...
  • Page 17 337410 113351 303115 Asennusside Tunnus Suomi English Svenska Kpl. Tunnus Suomi English Svenska Kpl. 337414 Tulppa Code Code 337412 Pistesuutinputki 113011 133630 Kuusiokoloruuvi M6x40 144981 O-rengas 16 x 2 337421 Putken kiinnikepari 12mm 1666 Kiinnityslevy Mounting plate Fästplatta 157302 T-haara T-connector T-koppling 133116...
  • Page 18 Happowa Oy tel. +358 400 863 514 www.happowa.fi myynti@happowa.fi...