Power Supplies - Cisco MDS 9200 Series Installation Manual

Cisco systems hub/switch installation guide
Hide thumbs Also See for MDS 9200 Series:
Table of Contents

Advertisement

Chapter 1
Product Overview
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Power Supplies

The Cisco MDS 9200 Series supports dual hot-swappable 845-W AC power supplies, each of which can
supply sufficient power to the entire chassis should one power supply fail. The power supplies monitor
their output voltage and provide status to the supervisor module. To prevent the unexpected shutdown of
an optional module, power management software only allows a module to power up if adequate power
is available.
The Cisco MDS 9200 Series power supplies can be configured to be redundant or combined. By default,
they are configured as redundant, so that if one fails, the remaining power supply can still power the
entire system. For information on how to configure the power supplies, see the Cisco MDS 9000 Family
NX-OS Fundamentals Configuration Guide.
The power supplies, which are accessed from the rear of the chassis, are illustrated in
Figure 1-24
1 Power supply switch
2 AC power connection
Table 1-12
Table 1-12
LED
Input OK
Fan OK
Output Fail
OL-19588-01
Cisco MDS 9200 Series with 845-W Dual Power Supplies
PWR-845-AC
PS2
1
2
100-240V 12-5A
50/60 Hz
ALL FASTENERS MUST BE FULLY ENGAGED
PRIOR TO OPERATING OF POWER SUPPLY
describes the LEDs for the Cisco MDS 9200 Series power supplies.
LEDs for the Cisco MDS 9200 Series Power Supplies
Status
Green
Off
Green
Off
Red
Off
4
PWR-845-AC
INPUT OK
FAN OK
OUTPUT FAIL
100-240V 12-5A
50/60 Hz
3
3 Power supply handle
4 Power supply LEDs
Description
AC input is good and power supply is functioning normally.
Power supply is turned off or is not seated properly in the
chassis.
Power supply fans are operating properly.
Fan is not operating or power supply is off.
Power supply is not in a stable state. If this indication
continues after initial power on, check that all connections
are secure, including the system fan tray.
Normal operation or power supply is turned off.
Cisco MDS 9200 Series Hardware Installation Guide
PS1
INPUT OK
FAN OK
OUTPUT FAIL
ALL FASTENERS MUST BE FULLY ENGAGED
PRIOR TO OPERATING OF POWER SUPPLY
Power Supplies
Figure
1-24.
1-35

Advertisement

Table of Contents
loading

Table of Contents