CM704B - 8/16 LAN Zone Expander
The CM704B allows you to expand the hard wired
zone capacity of selected Solution control panels.
Each CM704B installed will add 8 or 16 zones to the
system depending on if single or split EOL monitor-
ing has been enabled. Table 1 below lists the panels
which are compatable with the CM704 as well as the
maximum number of expanders that can be
supported on each one.
The CM704B is supplied as a PCB module and can be
installed in the same cabinet as the main panel or
remotely from the panel via the 4 wire LAN or BUS
connection. The CM704 requires only one module
space in the enclosure.
Sensors connected to the zone expander can be
powered from the Solution panel,(1) or from an
external power supply like the CM720B power
supply.(2) The zone power jumper on the CM704B
must be set to EXT when using an external supply.
A dedicated tamper input and service keypad input
is also provided.
The CM704B includes a 3 way dip switch which is
used to select the zone expander's address or node
number. See Switch 1 labelled ADDRESS in the
wiring diagram on the following page.
When only one CM704B is installed, then the
three DIP switches should be left in the OFF
or default position. To assist with installation,
the CM704B includes indicators to show LAN
and Zone Power status at all times.
Programming Considerations
1) The CM704 expander does not need to be
enabled via panel programming. The panel
will recognise it after a power cycle.
2) The EOL resistor value selected in the panel
programming is global for all zones in the
system including zones on expanders.
3) Some Zones are defaulted as Not Used.
These must be programmed as valid zone
types before they become active.
4) When using a normally open device, you
will need to program the Inverted Seal option
for each N/O zone.
(1): Provided the maximum available LAN current is not exceeded.
(2): The CM720B is a LAN Monitored 1 amp Switch Mode Power Supply with Pulse Battery Charger.
Copyright © 2007
E&OE
N/C - No EOL Zone
�� �
���
�� �
N/C - Single EOL Zone
ALARM
�� �
���
�� �
ALARM
N/C - Split EOL Zone
�� �
���
�� �
N/C - Zone with Tamper
N/C
1
�� �
TAMPER
���
2
�� �
2K2 + 6K8 and 10K + 10K EOL Resistor Values options can
also be selected for Alarm and Tamper Monitoring.
Module Address Switches and Zone Numbering
Address
SW1 SW2 SW3
Number
Address 1 =
OFF OFF OFF
Only 1 x CM704 can be fitted to the Solution16i ICON panel
Solution 16e GRAPHIC Panel
Address
SW1 SW2 SW3
Number
Address 1 =
OFF OFF OFF
Address 2 =
ON OFF OFF
Address 3 =
OFF ON OFF
Address 4 =
ON ON OFF
Address 5 =
OFF OFF ON
Address 6 =
ON OFF ON
Address 7 =
OFF ON
Address 8 =
ON ON
Up to 8 x CM704 can be fitted to the Solution 16e panel
Table 1: CM704 BConfiguration Options
ZONE WIRING OPTIONS
N/O - No EOL Zone
�� �
N/C
ZONE 1
���
ZONE 2
N/C
2
�� �
N/O - Single EOL Zone
N/C
�� �
ZONE 1
���
ZONE 2
N/C
�� �
N/O - Split EOL Zone
N/C
ALARM
ZONE 1
(3K3 EOL)
�� �
N/C
���
ALARM
ZONE 9
(6K8 EOL)
�� �
N/O - Zone with Tamper
TAMPER
(6K8 EOL)
�� �
ZONE 1
N/C
ALARM
���
(3K3 EOL)
�� �
Solution 16i ICON Panel
Zones Numbered
(Single EOL)
9 to 16
Zones Numbered
(Single EOL)
9 to 16
17 to 24
25 to 32
33 to 40
41 to 48
49 to 56
ON
57 to 64
ON
65 to 72
P/N: CM704BIRG Bosch Rev 1.2
N/O
ZONE 1
ZONE 2
N/O
ALARM
N/O
ZONE 1
N/O
ZONE 2
ALARM
N/O
ALARM
ZONE 1
(3K3 EOL)
N/O
ALARM
ZONE 9
(6K8 EOL)
TAMPER
(6K8 EOL)
N/C
TAMPER
ZONE 1
ALARM
N/O
(3K3 EOL)
Zones Numbered
(Dual EOL)
N/A
Zones Numbered
(Dual EOL)
17 to 32
33 to 48
49 to 64
65 to 80
81 to 96
97 to 112
113 to 128
129 to 144
Page  1

Advertisement

loading

Summary of Contents for Bosch CM704B

  • Page 1 Solution control panels. N/C - No EOL Zone N/O - No EOL Zone Each CM704B installed will add 8 or 16 zones to the �� � �� � system depending on if single or split EOL monitor-...
  • Page 2 8723) = 1500m. See manual for complete wiring instructions. Operating Environment: 0˚ to 55˚C RH 5 to 85% at 30˚C non-condensing. BOSCH SECURITY SYSTEMS The CM704B can be mounted in either the MW700 or MW710 Fixing Method: 25 Huntingwood Drive enclosures using clip in PCB mounts - supplied.