Honeywell HE360A1027 Installation Instructions Manual

Humidifier and installation kit
Table of Contents

Advertisement

Available languages

Available languages

HE360 Humidifier and
Installation Kit
WELCOME
To the comfortable world of humidified air. When you use
your Honeywell humidifier, notice that your skin is not as
dry, and that your scratchy throat and irritated nasal
passages that aggravate allergies and asthma are
steadily improving.
You have also taken the first step in reducing the zapping
you create when you walk on your carpet and then touch
your TV, computer, metal door knob or your pet. Your
furniture and woodwork are also benefitting from the
difference that humidified air makes.
Congratulations! You have just made a great investment
in improving the comfort of your home.
APPLICATION
This kit contains your new Honeywell HE360 Humidifier,
H8908 Humidistat and all the accessories required for
installation.
INSTALLATION
Preparing for the Installation
Be sure to identify all the required (Table 1) accessories
(included) and make sure the appropriate tools are
available before beginning the installation.

INSTALLATION INSTRUCTIONS

Required Accessories (Included)
Required Tools
Table 1. Required Accessories.
Quantity
Accessory (Item Quantity)
Humidifier Parts and Accessories
20 ft
18 gauge, two-strand thermostat wire
(6.2m)
20 ft
1/4 in. (6.35 mm) OD feed water tubing
(6.2m)
10 ft
1/2 in (12.7 mm) ID drain tubing
(3.1m)
1 bag
Connecting and mounting hardware:
Wire nuts (4)
No. 8 sheet metal screws (18)
Drain tube clamp
Feed tube mounting clamps (6)
Brass inserts (2)
Plastic compression rings (2)
1
H8908 Humidistat
1 bag
Saddle Valve Assembly:
Saddle valve and top clamp (1)
Threaded bottom clamp (1)
Bolts (2)
Rubber gasket (1)
Brass insert (1)
Plastic bushing (1)
69-2517EF-01

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell HE360A1027

  • Page 1: Installation Instructions

    Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, notice that your skin is not as dry, and that your scratchy throat and irritated nasal passages that aggravate allergies and asthma are steadily improving.
  • Page 2 • If you do not have a drain available, we recommend that you install the Honeywell Whole House Drum or Disk Humidifier. Make sure that the 10 ft (3.1m) of drain tubing is adequate to reach from the humidifier drain connection to the floor drain.
  • Page 3: Installing The Humidifier

    • Select location with access to an outlet. If not available, contact an electrician to have one installed. • Make sure that the humidifier cord is adequate to reach from the humidifier to the outlet. • Make sure that the 20 ft (6.2m) of thermostat wire is adequate to reach from the humidifier solenoid, to the sail switch, to the humidistat.
  • Page 4: Connecting The Plumbing

    PLASTIC TABS (2) DRAIN TUBING Fig. 5. Installing humidifier on duct. 11. Reinstall the humidifier pad assembly in the humidi- fier housing. IMPORTANT Be sure to reconnect the water feed tube and ensure that the tube is not pinched or kinked.
  • Page 5: Installing The Humidistat

    TO BOTH THE + AND – PORTS ON THE AIR FLOW SWITCH Fig. 9. Mounting the pressure switch. HE360 HUMIDIFIER AND INSTALLATION KIT 4. Cut a 3/4-in. diameter hole in the duct within 10 feet of the switch to ensure the provided tubing reaches the pressure tap elbow.
  • Page 6: Testing Humidifier Operation

    1. Run the two-strand thermostat wire from the humid- 2. Cut lengths of thermostat wire to reach between NOTE: Humidistat and pressure switch can be wired in 3. At the humidifier, connect the black and white con- 4. At the humidistat, connect both black conductors to TESTING HUMIDIFIER...
  • Page 7: Maintaining

    OPERATION How Your Humidifier Works Your Honeywell humidifier uses the principle that vapor (evaporated water) is created when warm air blows over a water-soaked area. As the vapor circulates, the relative humidity rises. Your humidity control monitors the relative humidity and activates the humidifier accordingly.
  • Page 8 13. Be sure the marked end of the pad is facing up. Place the tray on the new pad. 14. Place the humidifier pad assembly in the humidifier housing. Be sure the water feed tube is placed in the guide slots.
  • Page 9 • Turn off humidity control and water until condensation is completely evaporated. • Turn humidity control down low enough to eliminate condensation caused by moisture from bathing, mopping, cooking, etc. If moisture persists, more ventilation is needed. HE360 HUMIDIFIER AND INSTALLATION KIT What to do 69-2517EF—01...
  • Page 10: Limited One-Year Warranty

    This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.
  • Page 11: Installation

    Félicitations ! En rendant votre maison plus confortable, vous venez de réaliser un investissement important. APPLICATION Cette trousse comprend un humidificateur HE360 et un humidistat H8908 de Honeywell ainsi que tous les accessoires nécessaires à l'installation. NOTICE D'INSTALLATION INSTALLATION Avant d'installer ce produit Il est important d'identifier tous les accessoires nécessaires (fournis) énumérés au Tableau 1 et d'avoir...
  • Page 12 • S'il n'y a pas de siphon à proximité, il est préférable d'installer l'humidificateur central à tambour ou à disque de Honeywell. Assurez-vous que le tuyau de vidange de 3,1 m (10 pi) est suffisamment long et permet de raccorder le tuyau de vidange de l'humidificateur au siphon de sol.
  • Page 13 Dans la gaine de reprise, l'humidostat doit être installé en amont de l'humidificateur ou en dérivation de manière qu'il puisse détecter avec exactitude l'humidité relative dans la pièce. Installez l'appareil à au moins 203 mm (8 po) en amont de l'humidificateur dans la gaine de reprise.
  • Page 14 HUMIDIFICATEURS HE360 ET TROUSSE D'INSTALLATION NIVEAU VIS À TÔLE (4) OUVERTURE VERS LA GAINE D'AIR ATTACHES EN PLASTIQUE (2) TUYAU DE VIDANGE Fig. 5. Installation de l'humidificateur sur une gaine. 11. Remettez l'ensemble écran évaporateur dans le boîtier de l'humidificateur. IMPORTANT Assurez-vous que le tube d’arrivée d’eau est raccordé...
  • Page 15 Installation du pressostat d'air IMPORTANT N'installez pas le pressostat dans un endroit où la température est inférieure à -40 °C ou supérieure à 88 °C. 1. Coupez l'alimentation électrique du TrueSTEAM avant l'installation. 2. Installez le pressostat à la verticale, de façon à ce que les connecteurs à...
  • Page 16 HUMIDIFICATEURS HE360 ET TROUSSE D'INSTALLATION INTÉRIEUR DU CONDUIT BRANCHEZ LE TUYAU SUR LA BORNE + SI LA PRISE DE PRESSION EST FIXÉE AU CONDUIT D'APPROVISIONNEMENT. Fig. 10. Installation de la tuyauterie. 8. Vous pouvez couper le tuyau afin de l'ajuster à la distance comprise entre le coude et le pressostat.
  • Page 17: Vérification Du Fonctionnement De L'humidificateur

    4. À l'humidostat, raccordez les deux conducteurs noirs aux deux bornes de l'humidostat. Connectez ensemble les deux conducteurs blancs à l'aide d'un serre-fils. VÉRIFICATION DU FONCTIONNEMENT DE L'HUMIDIFICATEUR LISTE DE VÉRIFICATION  L'humidificateur est de niveau.  Le câblage des commandes a été vérifié à l'aide du schéma de circuit.
  • Page 18 HUMIDIFICATEURS HE360 ET TROUSSE D'INSTALLATION AVERTISSEMENT Risque de blessures graves. Les pièces mobiles peuvent causer des chocs électriques ou des blessures. Coupez l’alimentation électrique et fermez l’arrivée d’eau avant d'enlever le couvercle. IMPORTANT Ne lubrifiez jamais les pièces de l'humidificateur. À...
  • Page 19: Dépannage De L'humidificateur

    DÉPANNAGE DE L'HUMIDIFICATEUR Problème Ce qu'il faut vérifier Fuite d'eau Joints qui fuient. Garnitures de tuyau en laiton. Fuite du robinet-vanne à étrier. L'eau ne s'écoule pas Électricité vers le siphon Humidostat Alimentation de l'humidostat Électrovanne Tuyauterie Robinet-vanne à étrier Humidificateur Tuyau de vidange Faible humidité...
  • Page 20 GARANTIE LIMITÉE DE UN AN Honeywell garantit que ce produit, à l’exception de l’écran évaporateur de l’humidificateur, est exempt de tout vice de fabrication ou de matière dans la mesure où il en est fait une utilisation et un entretien convenables et ce, pour une période de un an à...

This manual is also suitable for:

He360He360a1019/u

Table of Contents