WIRELESS KITS (DT01*, DS01G, DD01E, DD01F)
MODE
FAN
DS01G
for additional assistance and explanation prior to ordering materials or cutting openings.
ATTENTION INSTALLING PERSONNEL
As a professional installer you have an obligation to know the product better than the customer.
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual.
it is possible to place yourself in a position which is more hazardous than when the unit is in operation.
Remember, it is your responsibility to install the product safely and to know it well enough
The precautions listed in this Installation Manual are intended as supplemental to existing practices.
However, if there is a direct conflict between existing practices and the content of this manual,
10/2018
IO-729E
www.amana-ptac.com
Due to policy of continued product improvement, the right is reserved to change specifications and design without notice.
I
NSTALLATION
DT01A
DT01G
The following installation instructions are for a typical installation.
Please contact your PTAC salesperson
This includes all safety precautions and related items.
Pay special attention to all safety warnings. Often during installation or repair
to be able to instruct a customer in its safe use.
Safety is a matter of common sense...a matter of thinking before acting.
Most dealers have a list of specific good safety practices...follow them.
the precautions listed here take precedence.
is a registered trademark of Maytag Corporation or its related companies
and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved.
Goodman Company, L.P.
5151 San Felipe, Suite 500
PTAC
I
NSTRUCTIONS
Houston, TX 77056
©
2009-2011, 2013-2018 Goodman
AIR CONDITIONING SENSOR
DD01E
AIR CONDITIONING SENSOR
DD01F
Company, L.P.

Advertisement

loading

Summary of Contents for Maytag Amana DT01 Series

  • Page 1 However, if there is a direct conflict between existing practices and the content of this manual, the precautions listed here take precedence. is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved.
  • Page 2 BEFORE BEGINNING INSTALLATION, PLEASE READ IMPORTANT NOTES BELOW • If devices are to be powered, field installed wiring will need to be run from thermostat location to unit location and from door sensor location to PTAC location and from wired magnet to sensor location. •...
  • Page 3 6B. Drill a 7/32” holes and tap plastic anchors into wall. Thermostat Installation for DS01G Kit Screw mounting base plate to wall. DO NOT SNAP THERMOSTAT INTO PLACE UNTIL AFTER BINDING NOTE: A DT01* must be installed on the digital PTAC unit PROCESS.
  • Page 4: Battery Powered

    3. Loosen set screws on wired terminals labeled Mounting Sensor/Door Magnet Installation REMOTE and insert wires into the openings. Tighten for DD01E and DD01F Kits set screws. (See following figure for switch connection) 4. Connect wires at door switch. DD01E and DD01F must be mounted on the top door frame as close to the door as possible in the horizontal position.
  • Page 5: Power Connection

    WIRED MAGNET AND POWERED DOOR Viewed from the back with the power block SENSOR OPTION in upper right corner. Power Connection In cases where there is no top door frame, the sensor will need to be mounted on the wall next to the door. In these cases a wired magnet (a field supplied single pole single Wired Magnet...
  • Page 6 Door Magnet Installation NOTE: Magnet buckets are shipped from the factory with the magnets in position A. The position may change based on the door and door frame alignment on page 6. Mount the door magnet holder on the front of the door where it will be as close as possible to the bottom of the motion sensor but no more then 1/8"...
  • Page 7 Security Screw location (located on each side of sensor) MAGNET MUST BE 15/16” FROM THE SENSOR MOUNTING PLATE MAGNET HOLDER MAY EXTEND 1/8” max. ABOVE THE DOOR (OR THE DD01E OR DD01F MAGNET MAY EXTEND BELOW THE DOOR FRAME) TO ENSURE THE MAGNET IS NO MORE THAN 1/8”...
  • Page 8 CONSTRUCTION STYLE 1 CONSTRUCTION STYLE 2 Place magnet in Position B Place magnet in Position A in instances when the door in instances when the door and frame align. extends into the room beyond the door frame. POSITION A POSITION B CONSTRUCTION STYLE 3 CONSTRUCTION STYLE 4 Place magnet in Position C...
  • Page 9 to obtain the 15/16” needed between the magnet and the sensor mounting plate on the door frame. DD01E THE ALIGNMENT GUIDE IS AT 15/16” FROM BACK PLATE. AIR CONDITIONING SENSOR ALIGNMENT GUIDES ON BOTTOM OF DD01E CENTER OF MAGNET (IN HOLDER) SENSOR MUST BE 15/16”...
  • Page 10 The display will alternate between displaying the feature code and the option code (factory default setting) up and down arrow keys to select Press the HEAT button one time to get into C1 mode and then the display will alternate between C1 and 0 - appears in the display).
  • Page 11 does not show on the display in 1-2 seconds, then press and release the white button a second time. NOTE: If both a DD01* and a DS01* are being bound, then the display will show Skip if there is no motion sensor. 4.
  • Page 12 CONFIGURATION SETTINGS CHART Configuration Code Description Option Code Description Interface Chassis Membrane* Wireless Remote Wired Thermostat Fan Operation Button present 7-Button, reverts to Cyclic Always run fan (even in Off) 7-Button, reverts to Continuous Reverse Cycle Operation Cooler Only Heat Pump* Service No Operation "Eo"...
  • Page 13 Setback Temps - DD01E / DD01F The DD01* and the DigiSmart™ control can be programmed for 3 different times to activate temperature setbacks. The current factory default temperature setbacks in v2.5 * software release are: 2º from set point in 30 minutes, 3º in one (1) hour, and 6º...
  • Page 14 9. Press HEAT key to scroll to third unoccupied setback time. Press either the up or down arrow to the desired third unoccupied setback time. 10. To exit configuration mode: Press the OFF key. NOTE: Configuration feature mode will also automatically exit if no keys are pressed for a period of two (2) minutes.
  • Page 15 Suggested Wireless Thermostat Locations in Typical Room Layouts Select thermostat mounting location about five feet above the floor, on an inside wall, out of direct sunlight, away from sources of radiant heat (lamps, fireplaces, heating and air conditioning equipment, etc.), away from windows or door to the outside, and avoid areas with poor air circulation.
  • Page 16 Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved. Goodman Company, L.P. • 5151 San Felipe, Suite 500 Houston, TX 77056 • www.amana-ptac.com © 2009 - 2011, 2013-2018 Goodman Company, L.P.