Preparation For Use - Kenwood CS-1022 Instruction Manual

Hide thumbs Also See for CS-1022:
Table of Contents

Advertisement

WEIGHT
ENVIRONMENT
Operating Temperature and
Humidity
for
Guaranteed
Specifications
Full Operating Temperature
and Humidity
ACCESSORIES
Probe
Instruction Manual
Replacement Fuse
0.8 A
0.5 A
• Circuit and rating are subject to change without notice due to developments in technology.
SAFETY
Before connecting the instrument to a power source,
carefully read the following information, then verify that
the proper power cord is used and the proper line fuse is in-
stalled for power source. The specified voltage is shown at
the left side of the power cord on the rear panel. If the
power cord is not applied for specified voltage, there is
always a certain amount of danger from electric shock.
Line voltage
This instrument operates using ac-power input voltages
that 1 0 0 / 1 2 0 / 2 2 0 / 2 4 0 V at frequencies from 50 Hz t o
6 0 Hz.
Power cord
The ground wire of the 3-wire ac power plug places the
chassis and housing of the oscilloscope at earth ground. Do
not attempt to defeat the ground wire connection or float
the oscilloscope; to do so may pose a great safety hazard.
The appropriate power cord is supplied by an option that is
specified when the instrument is ordered.
The optional power cords are shown as follows in Fig. 1.
Line fuse
The fuse holder is located on the rear panel and contains
the line fuse. Verify that the proper fuse is installed by
replacing the line fuse.
6
CS-1022
CS-1021
Approx. 8.8 kg
2

PREPARATION FOR USE

CS-1012
Approx. 8.4 kg
0°C to 40°C, 85% maximum RH
0°C to 50°C, 90% maximum RH
1
2
2
EQUIPMENT PROTECTION
1 . Never allow a small spot of high brilliance to remain sta-
tionary on the screen for more than a f e w seconds. The
screen may become permanently burned. A spot will oc-
cur only when the scope is set up for X-Y operation and
no signal is applied. Either reduce the intensity so the
spot is barely visible, switch back to normal sweep
operation when no signal is applied, or set up the scope
for spot blanking.
2. Never cover the ventilating holes on the top of the
oscilloscope,
as
temperature inside the case.
3. Never apply more than the maximum rating to the
oscilloscope inputs.
C S - 1 0 2 2 , 1 0 2 1 , 1 0 1 2 ;
jacks
CS-1020, 1 0 1 0 ;
A
EXT TRIG INPUT and Z AXIS INPUT
jacks
5 0 V (dc + ac peak)
Never apply external voltage to the oscilloscope output
terminals.
4 . Always connect a cable from the earth ground (GND)
jack of the oscilloscope t o the chassis of the equipment
under test. Without this caution, the entire current for
the equipment under test may be drawn through the
probe clip leads under certain circumstances. Such con-
CS-1020
CS-1010
Approx. 8.1 kg
1
this
will
increase
the
C H 1 , CH2 INPUT jacks
5 0 0 Vp-p or 2 5 0 V (dc + ac peak)
EXT TRIG INPUT and Z AXIS INPUT
5 0 V (dc + ac peak)
VERT INPUT jack
5 0 0 Vp-p or 2 5 0 V (dc + ac peak)
operating

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-1021Cs-1012Cs-1020Cs-1010