Download Print this page
Quincy lab 140E Series Operating Manual

Quincy lab 140E Series Operating Manual

General purpose incubators

Advertisement

Quick Links

uincy
ab
SPECIFICATIONS
Interior Dimensions
Exterior Dimensions
Weight (lbs)
Cubic Foot Capacity
Standard Electrical
Temperature Range
Common Unit Specifications
Operating Environment: Indoor use, altitude to 6,500 ft. (2,000m) Installation Category II,
Storage Temperature:
Approvals:
Compliance:
Common Unit Construction
Exterior: Powder-Coated Steel
Insulation: Fiberglass
Thermo-control: PID Microprocessor
Issue Rev A 0122
Copyright Quincy Lab Inc. 2022
Quincy Lab, Inc.
Model 12-140E
MODEL
10-140E
12x10x10
INCHES W x H x D
31x25x25
(CM) W x H x D
13x15x11
INCHES W x H x D
33x38x28
(CM) W x H x D
19 lbs
115 / 120*
VOLTS / WATTS
Pollution Degree 2, ambient temperature 10
80% RH maximum.
o
-10
C/14
Underwriter's Laboratory Listed, Laboratory Equipment, C/UL
United States/Canadian. E212550 (115VAC models only)
UL Standard 61010-1, IEC 61010-1, 2nd Edition.
109. Shore Dr.
General Purpose Incubators
OPERATING MANUAL
MODEL
12-140E
18x16x12
46x41x30
19x21x13
48x53x33
33 lbs
115 / 235*
o
o
o
F to 70
C/158
F, 70% RH maximum.
Interior: Aluminum
Door: 140E: Acrylic, 180E: Steel Insulated
Heater: Resistive-Tubular Incoloy
Burr Ridge, Illinois 60527
Model Series 140E & 180E
Model 10-180E
MODEL
MODEL
10-180E
12-180E
12x10x10
18x16x12
31x25x25
46x41x30
13x15x11
19x21x11
33x38x28
48x53x33
19 lbs
33 lbs
115 / 270*
115 / 385*
o
o
o
C/50
F to 35
C/95
1-800-482-HEAT (4328)
o
F,
PAGE 1

Advertisement

loading

Summary of Contents for Quincy lab 140E Series

  • Page 1 Exterior: Powder-Coated Steel Interior: Aluminum Insulation: Fiberglass Door: 140E: Acrylic, 180E: Steel Insulated Thermo-control: PID Microprocessor Heater: Resistive-Tubular Incoloy Issue Rev A 0122 Copyright Quincy Lab Inc. 2022 Quincy Lab, Inc. 109. Shore Dr. Burr Ridge, Illinois 60527 1-800-482-HEAT (4328) PAGE 1...
  • Page 2: Safety Precautions

    Safety Precautions Safety Precautions Read Operating Instructions Thoroughly Prior to Operation Read Opera�ng Instruc�ons thoroughly prior to opera�on and observe the following safety precau�ons: • Use only a grounded outlet that is rated for your model's electrical requirement. • Do not modify the oven or factory control se�ngs to operate the oven above the stated maximum opera�ng temperature. •...
  • Page 3 Menu Level Functions Guide To navigate the controller's menu, please refer to the easy-to-use Menu Guide below: Menu setting changes can be done quickly with our 5-button digital microprocessor. Your incubator's controller allows you to easily do the following: Auto-tune your Incubator for maximum efficiency Set the operating set-point temperature Lock the set-temperature Select between degrees Fahrenheit or Centigrade...
  • Page 4 Auto-tune The control's P.I.D values have been derived from a performed tuning at the factory using the AT-1 option which allows for optimal performance and faster response time. You may, however, choose to tune your incubator to your specific application and/or most used set-point temperature by selecting and performing one of the tuning options shown below.
  • Page 5 Chamber Loading Understanding the unit's light pressure thermal convec�on and "load-effect" are necessary to op�mize unit performance. Ar�cle or media processing �mes and/or uniformity are largely dependent on load density and posi�oning. Important guidelines to chamber loading and processing: Load the incubator so that air circula�on within the chamber is not impaired. Leave a space between ar�cles on the shelf.
  • Page 6: Maintenance

    For a complete list of replacement components, part and additional equipment, visit us on the web at www.quincylab.com Technical Support If you have any ques�ons or need technical assistance, contact Quincy Lab technical support for further assistance, or visit us www.quincylab.com on the web at Email: information@quincylab.com...

This manual is also suitable for:

180e series10-140e12-140e10-180e12-180e